
Voltage
... Transformers convert AC electricity from one voltage to another with little loss of power through inductively coupled electrical conductors. Transformers work only with AC voltage Step-up transformers increase voltage. Step-down transformers reduce voltage. ...
... Transformers convert AC electricity from one voltage to another with little loss of power through inductively coupled electrical conductors. Transformers work only with AC voltage Step-up transformers increase voltage. Step-down transformers reduce voltage. ...
112AMX AC Source, 1 Phase, 1200VA
... a high degree of versatility and ease of use for applications ranging from simple, manually controlled frequency conversion to harmonic testing and sophisticated programmable transient simulation. AC TEST POWER All 112AMX models are equipped with a powerful micro-controller with the ability to opera ...
... a high degree of versatility and ease of use for applications ranging from simple, manually controlled frequency conversion to harmonic testing and sophisticated programmable transient simulation. AC TEST POWER All 112AMX models are equipped with a powerful micro-controller with the ability to opera ...
CN-0014 利用AD5383 DAC实现32通道可编程电压以及出色的温度漂移性能
... supply pins. Additional decoupling using a series connected ferrite bead may be required. The AD5383 digital (DVDD) power supply can operate from a 3 V or 5 V supply, which provides for maximum flexibility when interfacing to digital components. Both supplies can be tied together to a common 5 V sup ...
... supply pins. Additional decoupling using a series connected ferrite bead may be required. The AD5383 digital (DVDD) power supply can operate from a 3 V or 5 V supply, which provides for maximum flexibility when interfacing to digital components. Both supplies can be tied together to a common 5 V sup ...
CN-0011 利用AD5382 DAC实现32通道可编程电压以及出色的温度漂移性能
... This design uses two separate 5.0 V power supplies—one to power the voltage reference and the analog portion of the AD5382 (AVDD), the other to power the digital portion of the AD5382 (DVDD). For best performance, a linear regulator should always be used to power the analog portion of the circuit. I ...
... This design uses two separate 5.0 V power supplies—one to power the voltage reference and the analog portion of the AD5382 (AVDD), the other to power the digital portion of the AD5382 (DVDD). For best performance, a linear regulator should always be used to power the analog portion of the circuit. I ...
1.2kV thru 44kV Class Dry-Type Medium Voltage (Power)
... Customer name. Customer location and customer order number shall identify all transmittals. Product Data including KVA rating, Temperature Rise, Detailed enclosure dimensions, Primary & Secondary nominal voltages, primary voltage taps, no load & full load losses, impedances, unit weight, warranty; E ...
... Customer name. Customer location and customer order number shall identify all transmittals. Product Data including KVA rating, Temperature Rise, Detailed enclosure dimensions, Primary & Secondary nominal voltages, primary voltage taps, no load & full load losses, impedances, unit weight, warranty; E ...
Easy solar-panel maximum-power-point tracking for pulsed
... help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and requirements. Nonetheless, such components are subject to these terms. No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) ...
... help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and requirements. Nonetheless, such components are subject to these terms. No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) ...
CAT IV or CAT III?
... This is a very inconvenient situation if a breakdown occurs. When a breakdown takes place, a lot of energy is concentrated on the instrument and accessories contact points because of their contact resistance. If the user tries to remove the leads during a breakdown, the arc and local burnings can ev ...
... This is a very inconvenient situation if a breakdown occurs. When a breakdown takes place, a lot of energy is concentrated on the instrument and accessories contact points because of their contact resistance. If the user tries to remove the leads during a breakdown, the arc and local burnings can ev ...
Chapter 5
... the I-V characteristics of the solar cell, Equation (2), and that of the load, Equation (3). We can find 1' and V' by solving these two equations simultaneously or using a graphical solution. I' and V' in the solar cell circuit are most easily found by using a load line construction. The I-V charact ...
... the I-V characteristics of the solar cell, Equation (2), and that of the load, Equation (3). We can find 1' and V' by solving these two equations simultaneously or using a graphical solution. I' and V' in the solar cell circuit are most easily found by using a load line construction. The I-V charact ...
2016 China International Conference on Electricity Distribution
... environmental conditions, the VM of PV array is approximately proportional to change when the Voc of PV array change. Approximate linear relationship exists between Vm and Voc, namely VM≈k1×Voc, in this paper k1=0.78*Voc is affected by illumination change slightly and is influenced by the temperatur ...
... environmental conditions, the VM of PV array is approximately proportional to change when the Voc of PV array change. Approximate linear relationship exists between Vm and Voc, namely VM≈k1×Voc, in this paper k1=0.78*Voc is affected by illumination change slightly and is influenced by the temperatur ...
SPIRIT-C Solar Powered Image Response Infrared Tracking
... Pulse Width Modulator The Direction input will be held high for clockwise or held low for counter clockwise The outputs then will be attached to the appropriate H bridge inputs ...
... Pulse Width Modulator The Direction input will be held high for clockwise or held low for counter clockwise The outputs then will be attached to the appropriate H bridge inputs ...
AN OVERVIEW OF UNITY POWER FACTOR POWER SUPPLY
... 400W AC to DC converter was presented, operating either as a rectifier, or as a UPFPS, supplied from AC sources of various frequencies. The UPFPS performance was tested at 50Hz, 60Hz and 400Hz supplying frequencies, with varying supply voltage and variable load. The UPFPS may operate in a wide suppl ...
... 400W AC to DC converter was presented, operating either as a rectifier, or as a UPFPS, supplied from AC sources of various frequencies. The UPFPS performance was tested at 50Hz, 60Hz and 400Hz supplying frequencies, with varying supply voltage and variable load. The UPFPS may operate in a wide suppl ...
Objective type questions and answers
... Thus, theoretically, for 50% of full load requirement the power input needed would be less than 13% of full load power. In a centrifugal pump when the flow discharge is reduced to 70% of the rated discharge a savings of 65 percent in power is theoretically possible. To achieve this savings, Solid st ...
... Thus, theoretically, for 50% of full load requirement the power input needed would be less than 13% of full load power. In a centrifugal pump when the flow discharge is reduced to 70% of the rated discharge a savings of 65 percent in power is theoretically possible. To achieve this savings, Solid st ...