• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Final Dec 2003
Final Dec 2003

... Why can higher voltages be used with Lab-on-a-chip type electrophoretic separations as compared to benchtop CE separations? What extraneous (to the chip) devices are typically needed in Lab-on-a-chip type ...
electronic-components-easy-guide
electronic-components-easy-guide

... measured in terms of Lumen ( lm ) or Milli lumen ( mlm ) b. Luminous intensity – is the luminous flux covering a large area. It is measured as Candela ( cd ) or milli candela ( mcd ) Brightness of LED is directly related to its luminous intensity. a. Luminous efficacy - is the emitted light energy r ...
Phy 440 Lab 8: Bipolar Transistors I
Phy 440 Lab 8: Bipolar Transistors I

... multimeter. This option sets the terminals of the multimeter so as to forward bias the junction and then to read the voltage across it. For a silicon transistor like the 2N2219 you expect to find a forward voltage of 0.6 or 0.7 volts. Test both the basecollector and the base-emitter junctions of you ...
Power Quality Measurements
Power Quality Measurements

... Analisys of Power quality measurements according to the Croatian Grid Code: • Limits for Voltage fluctuations and Frequency variations simmilar to EN 50160 • Allowed contribution of power plant on distribution grid for • THDU, (2,5 % Un, for 0,4 kV level) • Flikers and • Voltage imbalance. This is t ...
NPN/PNP Splitter
NPN/PNP Splitter

... NPN/PNP Splitter DIN rail mounted NPN/PNP Splitter was designed for industrial applications to recognize type of connected switches (proximity, limit switches, etc.) and convert PNP or NPN input signals into separated PNP and NPN outputs signals. ...
Electrical Measurements
Electrical Measurements

... back through the circuit rather than through the device. (In addition injecting current into a circuit at random places may damage some components in the circuit.) Thus to measure the resistance of something, you almost always have to disconnect at least one end of it from its circuit. ...


... The STATCOM is the solid-state-based power converter version of the SVC. The concept of the STATCOM was proposed by Gyugyi in 1976. Operating as a shunt-connected SVC, its capacitive or inductive output currents can be controlled independently from its connected AC bus voltage. Because of the fast-s ...
MPS CONFIDENTIAL DO N OT DISTRIBUTE
MPS CONFIDENTIAL DO N OT DISTRIBUTE

... The MP4020 is a primary-side-control offline LED lighting controller which can achieve high power factor and accurate LED current for an isolate lighting application in a single stage converter. The proprietary real current control method can control the LED current accurately from the primary side ...
six light troubleshooting.fm
six light troubleshooting.fm

Midterm Project on Advanced Amplifier Design
Midterm Project on Advanced Amplifier Design

... work/research and thus more interesting to you, you are welcome to propose changes in some of the specifications, in particular in terms of speed, power, and supply voltage. However, you would need to submit your proposal with explanation and justification to me as soon as possible for approval. ...
Power Detector - Mini Circuits
Power Detector - Mini Circuits

... NOTE: When soldering the DC connections, caution must be used to avoid overheating the DC terminals. See Application Note AN-40-10 . ...
Feb 1999 Switched Capacitor Voltage Regulator Provides Current
Feb 1999 Switched Capacitor Voltage Regulator Provides Current

... output voltage ripple is low. Note that C1 and COUT do not need to be matched, as their voltages are equalized on each cycle. Figure 3 shows the actual circuit. Instead of halving the input voltage, the LT1054 modulates the input current (through switch 1 of Figure 2) to regulate the output voltage. ...
Ttitle, Title, Title, Ttitle, Title, Title, Ttitle, Title, Title
Ttitle, Title, Title, Ttitle, Title, Title, Ttitle, Title, Title

... the semiconductor device. Now the main purpose of this technology can be found in the output voltage waveform: instead of the full positive or negative DC link voltage, now half the DC link voltage is available for each side. ...
IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSRJEEE)

... which is compensated by static VAR compensators (SVC). There are two techniques for controlling the converter circuit which are voltage control and PWM control. In voltage control method chopper circuit is used for varying the DC source voltage. It has several drawbacks such as high harmonics conten ...
report - Auburn Engineering
report - Auburn Engineering

... From the data in the table, the maximum energy savings we are able to achieve is almost 95%. V. CONCLUSION This project has examined the operation of a circuit in a subthreshold region. We have shown that a circuit can still function as its intended design when operated below the threshold voltage. ...
Télécharger
Télécharger

ES1A - ES1D
ES1A - ES1D

... 1. Life support devices or systems are devices or 2. A critical component is any component of a life systems which, (a) are intended for surgical implant into support device or system whose failure to perform can the body, or (b) support or sustain life, or (c) whose be reasonably expected to cause ...
Example: This circuit is equivalent to a single capacitor having
Example: This circuit is equivalent to a single capacitor having

miniature, i/o proportional high voltage power supplies
miniature, i/o proportional high voltage power supplies

... *1 Caution: Models G40, G50 & G60 do not have internal bleeder resistors on the output. Provisions must be made externally to discharge the output capacitors if this feature is desired. *2 At Maximum Rated Output Voltage. ...
DC Current Transducer DK-B420 I = 150 .. 400 A
DC Current Transducer DK-B420 I = 150 .. 400 A

... hazardous live voltage (eg. primary conductor, power supply). The user shall ensure to take all measures necessary to protect against electical shock. The transducer is a build-in device containing conducting parts that shall not be accessible after installation. A protective enclosure or additional ...
preliminary plan
preliminary plan

How Does Electric Power Quality Effect Your Business?
How Does Electric Power Quality Effect Your Business?

... Single-phase non-linear loads are prevalent in modern office buildings. Three-phase, non-linear loads are widespread in commercial office buildings, factories and Government facilities. Does Electric Power Quality Affect Electricity Bills? It is important to understand that not only does poor qualit ...
Electron Impact Excitation of Helium
Electron Impact Excitation of Helium

...  Remove the cap from the chart recorder pen and rotate the pen into position.  With the “PEN” switch in the “up” position, turn on chart recorder “ON” and move the switch to the “SERVO ON” position. Switch the “PEN” to “down” to mark the position where the anode voltage is +12 V. Raise the pen and ...
LithiumIon Battery Char
LithiumIon Battery Char

... Design a Lithium Ion Battery Charger that is capable of safely charging 16 parallel packs of 90 cells in series. ...
Coupling modules - OCTO series Technical data 5.01-4
Coupling modules - OCTO series Technical data 5.01-4

< 1 ... 1346 1347 1348 1349 1350 1351 1352 1353 1354 ... 1640 >

Voltage optimisation

Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.Voltage optimisation systems are typically installed in series with the mains electrical supply to a building, allowing all its electrical equipment to benefit from an optimised supply.