• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Interpretation of power phenomena in three phase systems with
Interpretation of power phenomena in three phase systems with

Power Quality Analysis in Microgrid
Power Quality Analysis in Microgrid

... (batteries, flywheel, super capacitor, etc.) along with controllable and critical loads [1]. The MG should be capable to operate either in “grid connected” or “island mode” of operation. In “grid connected” mode, the power can be exported or imported between MG and utility grid according to the ener ...
UPS Sentinel XR PLUS 5-10kVA
UPS Sentinel XR PLUS 5-10kVA

... suppress atmospheric interference • Advanced diagnostics: status, measurements and alarms available on the custom LCD display • Very low noise level (<40dBA): for installation in any environment thanks to the PWM digitally controlled ventilation that is load dependent, and the use of an inverter wit ...
Galvanically Isolated Modular Converter - Infoscience
Galvanically Isolated Modular Converter - Infoscience

Products and solutions for solar energy
Products and solutions for solar energy

... Using the distributed MPPT, each panel operates at its maximum power point and so the overall efficiency of the whole photovoltaic system is increased compared to a traditional string or central inverter based architecture. The module-level communications and real-time monitoring features allow the ...
600W~3000W
600W~3000W

... The inverter will operate most AC loads within its power rating. When deeming whether a microwave over can be operated by the inverter, remember that the power commonly advertised for microwave ovens is the cooking power (the power delivered to the food) not the power actually consumed by the microw ...
DCA-20PC Series - Murata Power Solutions
DCA-20PC Series - Murata Power Solutions

... A DMS-BZL4-C bezel assembly with sealing gasket is supplied with each ammeter. ➀ The noted full-scale values are the external load currents that the ammeter is designed to measure. This current enters TB-1 (-SHUNT), passes through the ammeter’s built-in shunt and exits via TB1-2 (+SHUNT). For all mo ...
From 10 to 100 kVA
From 10 to 100 kVA

... M4T has a processor dedicated to calculations and signal quality: the DSP has the ability to process a huge amount of information in real time (20 million instructions per second). On one hand, the DSP controls the rectifier and the network current quality and, on the other, it controls the output vo ...
Aalborg Universitet A Direct Voltage Unbalance Compensation Strategy for Islanded Microgrids
Aalborg Universitet A Direct Voltage Unbalance Compensation Strategy for Islanded Microgrids

Single Phase Dual Full Bridge Bi-directional DC
Single Phase Dual Full Bridge Bi-directional DC

DEF main document JOZ
DEF main document JOZ

... Fig. 1 shows the microgrid system under consideration, in which both three-phase and single-phase microgrids areas are connected to the utility grid through a three-phase BTB converter. Note that phase-A and phase-C contains DG units and some local loads, while phase-B has no DGs but loads. In such ...
A Direct Voltage Unbalance Compensation Strategy for
A Direct Voltage Unbalance Compensation Strategy for

... wind turbines, photovoltaic systems and micro-turbines, have gain a great increasing interest since they are economic and environment friendly. In general, power electronic converters are used as interfaces between DERs and the grid [1], such that electrical power with good quality and high reliabil ...
razor based dvs using multiprecision and operand
razor based dvs using multiprecision and operand

... Adapting to the run-time workload of the targeted application, razor flip-flops combine with a dithering voltage unit, because of this the multiplier is able to achieve the lowest power consumption. Use of single switch dithering voltage unit and razor flip-flops help to minimize the safety margins ...
Comparison of Multi-MW Converters Considering the  Department of Energy Technology
Comparison of Multi-MW Converters Considering the Department of Energy Technology

PFC FrontEndTM Power Factor Corrected AC-DC FrontEnd
PFC FrontEndTM Power Factor Corrected AC-DC FrontEnd

... The PFC FrontEnd consists of an off-line single phase, power-factor-corrected front end, EMI filter, cooling fan, customer interface and associated housekeeping circuits. Input AC mains voltage is applied to a terminal block. The input current is passed through an EMI filter designed to meet conduct ...
Power Measurements for Compute Nodes: Improving
Power Measurements for Compute Nodes: Improving

AP4201274279
AP4201274279

... the Cuk converter in 1977. The advantages of integrated magnetic techniques are that the amount of core material is reduced and the component count is reduced. The significant advantage is that the ripple in one winding can be dumped to another winding, thus achieving a ripple free input or output c ...
testing harmonic limits in
testing harmonic limits in

... this method, the harmonics and PF are calculated during the simulation. Because the user can interactively change parameters of the SMPS, he has the possibility of tuning the SMPS during simulation. Compared to offline calculations of harmonics, the online method is faster and allows the user to opt ...
Symmetra Brochure - Advanced Power Technology
Symmetra Brochure - Advanced Power Technology

... Symmetra Power Array achieves N+1 redundancy and higher through proven power sharing technology. Power sharing means that all of the power modules in a Power Array run in parallel and share the load evenly. N+1 redundancy means running one extra module than will support your full load. In this way, ...
SELC 6000 HID Ballast Range
SELC 6000 HID Ballast Range

... Lamp Power Variation Less than 3% over 180V to 260V supply voltage ...
Innovative Techniques for Extremely Low Power Consumption with
Innovative Techniques for Extremely Low Power Consumption with

Average Power Balancing Control of a STATCOM based on the
Average Power Balancing Control of a STATCOM based on the

Lesson – 12
Lesson – 12

... 12.3.2 Operation of a three phase uncontrolled bridge rectifier supplying a capacitive load A three phase uncontrolled bridge rectifier supplying a capacitive load is a very popular power electronic converter. It is very widely used as the front end of a variable voltage variable frequency dc – ac i ...
J.M. Rivas, J. Shafran, R.S. Wahby, and D.J. Perreault, New Architectures for Radio-Frequency dc-dc Power Conversion, IEEE Transactions on Power Electronics , Vol. 21, No. 2, March 2006, pp. 380-393.
J.M. Rivas, J. Shafran, R.S. Wahby, and D.J. Perreault, New Architectures for Radio-Frequency dc-dc Power Conversion, IEEE Transactions on Power Electronics , Vol. 21, No. 2, March 2006, pp. 380-393.

... wherein devices are switched with little or no voltage across them, is necessary to achieve the ultra-high operating frequencies considered here. Likewise, at these frequencies device gating loss becomes a major consideration, and some form of resonant drive is usually required [23]–[26]. This appro ...
Aalborg Universitet
Aalborg Universitet

... deadbeat) method has been adopted ‎[23], ‎[24]. Besides its fast dynamic and simplicity, the deadbeat current control has some limitations, especially when it is applied to a SCR unit. In this paper those issues with a possible solution have been addressed. Finally, the current modulator is synchron ...
< 1 ... 58 59 60 61 62 63 64 65 66 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report