• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
The control of VSC-HVDC and its use for large industrial power
The control of VSC-HVDC and its use for large industrial power

... in Figure 2.2(a). The two ac systems interconnected may have the same or different nominal frequency, i.e. 50Hz and 60Hz (The back-to-back link can be used to transmit power between two neighboring non-synchronous systems). Examples of such system can be found in Japan and South America [15]. The dc ...
DeltaV Bulk Power Supplies
DeltaV Bulk Power Supplies

SiC Power Schottky Diodes in Power Factor Correction Circuits
SiC Power Schottky Diodes in Power Factor Correction Circuits

... SBDs in the near future is in the the AC input line see near-unity power factor, as required requirements. The power-factor correction SiCtoSchottky Barrier Diode (SBD) lie in itsby new legal CCM power correction (PFC) circuit. (PFC) circuits can be divided in two broad categories: Boost-converter d ...
International
International

... The maximum output power of the IPS is dependent on the IPS unit power rating and input voltage. The 855222XX series IPS is rated for 1500W, but cannot deliver full power at all allowable input voltages. The user must be aware of this limitation if trying to run the IPS at full power with minimum in ...
chapter 1 - ePrints USM
chapter 1 - ePrints USM

... Due to the strict requirements from consumer to utility, consumers are provided with redundant incoming feeders and the distribution network is supplied by several sources from transmission system. The network is also operated by extensive network control system to provide stable and reliable supply ...
Conduction Losses and Common Mode EMI Analysis on
Conduction Losses and Common Mode EMI Analysis on

Notional System Report Two - Rev18
Notional System Report Two - Rev18

... Jonathan Crider, Purdue University Hamid Ouroua, University of Texas at Austin Enrico Santi, University of South Carolina Scott Sudhoff, Purdue University ...
wdyrc tech sheet
wdyrc tech sheet

... CAUTION - Hazards or unsafe practices which COULD result in minor personal injury or product or property damage. ...
DEWA Standards for Distributed Renewable Resources Generators
DEWA Standards for Distributed Renewable Resources Generators

... Apparent Power - Is the product of voltage (in volts) and current (in amperes). It is usually expressed in kilovoltamperes (kVA) or megavolt-amperes (MVA) and consists of a real component (Active Power) and an imaginary component (Reactive Power). In case of inverters, the rated apparent power corre ...
High Power DC/DC Converter Topologies
High Power DC/DC Converter Topologies

Power Supply Test Equipment
Power Supply Test Equipment

3-Phase PM Synchronous Motor Nyachulue Njita High Speed with Low Torque
3-Phase PM Synchronous Motor Nyachulue Njita High Speed with Low Torque

... The objective of this project was to design a 3-phase PM Synchronous motor with a constant speed at a specific frequency value supplied from a variable frequency drive (VFD) source. The thesis explains in detail the effect of varying the frequency values supplied from the VFD system on the motor’s s ...
Date:- 12 December 2011
Date:- 12 December 2011

2004/05 Power Supply Design Seminar Book
2004/05 Power Supply Design Seminar Book

... important issue in the design of any electrical equipment which is liable to come into contact with a human operator or servicing individual. And this issue should be even more obvious when the equipment is designed to operate from a source of power which could experience or deliver voltage levels t ...
Steady State Operation and Control of Power
Steady State Operation and Control of Power



... first step is to extract the DG reference currents from the sensed load currents by applying the stationary reference frame and then transferred into synchronous reference frame method, and then, the reference currents are modified, so that the delay will be compensated. The transformed variables ar ...
Flexible AC/DC Grids in Dymola/ Modelica - IEA
Flexible AC/DC Grids in Dymola/ Modelica - IEA

Fundamentals Handbook
Fundamentals Handbook

... You may want to service the UPS yourself. If that’s the case, look for a unit that allows you to add capacity with power and/or battery modules. While modular solutions—including multiple, paralleled systems—are often a more affordable option initially, they can be a more expensive solution over the ...
SMPS AC/DC Reference Design User`s Guide
SMPS AC/DC Reference Design User`s Guide

20 V, 500 mA, Low Noise LDO Regulator with Soft Start  ADP7105
20 V, 500 mA, Low Noise LDO Regulator with Soft Start ADP7105

Optimizing gas generator efficiency in a forward Kelly, Ryan L.
Optimizing gas generator efficiency in a forward Kelly, Ryan L.

Demand Load
Demand Load

... Traditional reports Crystal reports Datablock reports One line diagrams with datablocks – export drawing to clipboard or print forms ...
Emission Limits for Customer Facilities Connected - Hydro
Emission Limits for Customer Facilities Connected - Hydro

MohdRedzuanAhmadMFKE2007TTT
MohdRedzuanAhmadMFKE2007TTT

... respond to the concerns related to electromagnetic fields. ...
POWER DISTRIBUTION SUB
POWER DISTRIBUTION SUB

< 1 2 3 4 5 6 7 8 9 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report