• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
- AEG Power Solutions
- AEG Power Solutions

... conducting a risk analysis w ith your customer. B) All other aspects such as low purchase and operating costs (efficiency) are - strictly speaking - secondary and must take second place to damage avoidance. Continuation of the example above: Type ...
DS32738741
DS32738741

... devices on noncritical paths to reduce leakage while using low-threshold devices on critical paths to maintain circuit speed. It reduces both active and standby leakage. However, this technique does not reduce the leakage on critical paths. Thus, it does not help much for practical circuits, whose p ...
Why is a transformer needed?
Why is a transformer needed?

... A three phase transformer must be selected so that any one phase is not overloaded. Each phase should have the additional 1 KVA rating required by the heater even though the heater will operate on one phase only. So, the transformer should have a minimum KVA rating of 2.8 + 1 + 1 + 1 or 5.8 KVA. A 6 ...
LTC3550-1
LTC3550-1

... Internal thermal feedback regulates the battery charge current to maintain a constant die temperature during high power operation or high ambient temperature conditions. The float voltage is fixed at 4.2V and the charge currents are programmed with external resistors. The LTC3550-1 terminates the char ...
Low Power CMOS Rectifier Design for RFID Applications
Low Power CMOS Rectifier Design for RFID Applications

... Application of the Bode–Fano criterion requires a purely resistive source impedance. We have so far assumed this, but antennas cannot satisfy this requirement. All antennas have reactive components to their terminal impedances because of near field energy storage. Only the impedance of a propagating ...
A Review Paper on Icing and Methods to De
A Review Paper on Icing and Methods to De

... appropriate power source when considering the conductor types and the different line length. Regular low voltage is used as power source to provide de-icing and current for the higher voltage level transmission line. In case the current is exceeding the thermal limit of the conductor many lines unde ...
LTC4412 - Low Loss PowerPath TM Controller in ThinSOT
LTC4412 - Low Loss PowerPath TM Controller in ThinSOT

8.  Electric Power AP1000 Design Control Document
8. Electric Power AP1000 Design Control Document

... The diesel-generator starting air subsystem consists of an ac motor-driven, air-cooled compressor, a compressor inlet air filter, an air-cooled aftercooler, an in-line air filter, refrigerant dryer (with dew point at least 10°F less than the lowest normal diesel generator room temperature), and an a ...
PPB PWM Power Block Installation Manual
PPB PWM Power Block Installation Manual

... insulation creepage spacings for electrical equipment and printed circuit boards. These drives are open type adjustable frequency motor drives that provide variable speed control to motors and provide overload protection and current limit control. ...
Issue Archive - Power Electronics Europe
Issue Archive - Power Electronics Europe

... on the basis of emissions over the entire fuel-cycle, meaning the emissions associated with the extraction, processing, distribution and final use of the energy that propels the car. While for conventional vehicles, these include emissions that result from extracting and processing crude oil as well ...
D.J. Perreault and V. Caliskan, “Automotive Power Generation and Control,” IEEE Transactions on Power Electronics , Vol. 19, No. 3, May 2004, pp. 618-630.
D.J. Perreault and V. Caliskan, “Automotive Power Generation and Control,” IEEE Transactions on Power Electronics , Vol. 19, No. 3, May 2004, pp. 618-630.

... be traced to the large armature synchronous inductances of the Lundell machine. Significant voltage drops occur across the synchronous inductances when current is drawn from the machine, and these drops increase with increasing output current and operating speed. Consequently, the Lundell alternator ...
- MATEC Web of Conferences
- MATEC Web of Conferences

... certain space to the development of power grid. ...
Intrinsically Safe Fieldbus Solutions
Intrinsically Safe Fieldbus Solutions

... Pepperl+Fuchs is the proven market leader for innovative and highly available components for your fieldbus according to IEC 61158-2. With quality components to fit your process automation system and demands in the field our highly reliable and energy-efficient design allows you to focus on the task ...
STANDARD REVIEW PLAN
STANDARD REVIEW PLAN

... onsite standby power sources and encompasses the grid, transmission lines (overhead or underground), transmission line towers, transformers, switchyard components and control systems, switchyard battery systems, the main generator, generator circuit breakers or load break switches (if provided), dis ...
designing an uninterruptible power supply based on the high
designing an uninterruptible power supply based on the high

... Vin 2 1 D N1 ...
Single-Phase High Efficiency Motor Testing
Single-Phase High Efficiency Motor Testing

... The motor used during this experiment was a three phase induction motor, produced by the Hampden Engineering Corporation. It is a four pole machine, with ⅓ horse power, model IM-100-6. The motor provides access to twelve terminals to be able to modify the three-phase connections. The SHE-motor desig ...
harmonics-shipboard-reportdraft1final
harmonics-shipboard-reportdraft1final

đây
đây

... Vin 2 1 D N1 ...
Aalborg Universitet Inducverters: PLL-Less Converters with Auto-Synchronization and Emulated Inertia Capability
Aalborg Universitet Inducverters: PLL-Less Converters with Auto-Synchronization and Emulated Inertia Capability

- IEEE PES Resource Center
- IEEE PES Resource Center

... Basler DECS applied to static excitation, Brush PRISMIC applied to static excitation, General Electric EX2000/2100/2100e bus fed potential source and static compound source and GENERREX-PPS or GENERREX-CPS; Canadian General Electric SILCOmatic 5, Basler/Eaton Cutler-Hammer ECS2100 static excitation ...
CRTE Power Capacitors
CRTE Power Capacitors

... and other "heavy“ applications) can be realized in different ways described as follows. Capacitors with star connection A widely used mode embodiment, but risky, provides a capacitors star connection (fig 1): in this way capacitors are subjected to a voltage equal to the nominal plant divided by √ 3 ...
Secondary-side rectification for an LLC resonant converter featuring
Secondary-side rectification for an LLC resonant converter featuring

Aalborg Universitet
Aalborg Universitet

FDMS3686S  PowerTrench Power Stage
FDMS3686S PowerTrench Power Stage

... to the part between D1 and S2. Input capacitors should be connected in parallel close to the part. Multiple input caps can be connected depending upon the application. 2. The PHASE copper trace serves two purposes; In addition to being the current path from the Power Stage package to the output indu ...
Increased transformer reliability through transparent
Increased transformer reliability through transparent

< 1 ... 22 23 24 25 26 27 28 29 30 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report