• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
- Spiral - Imperial College London
- Spiral - Imperial College London

... different power factor of the non-critical load. In all cases the ES is considered to be in voltage support (i.e. capacitive) mode as indicated by the negative sign of QES. For a purely resistive non-critical load, QES and QSL are equal and are shown by the black trace in Fig. 6(b). QES and QSL for ...
Instantaneous Reactive Power and Power Factor of
Instantaneous Reactive Power and Power Factor of

... complex number format of the instantaneous phasors, such as the voltages, Vu,vb, and V,, are given in (1). They have the same magnitude but are 120-degrees apart. ...
Document
Document

... It is tedious to plot constant gain circles for bilateral case where in is a function of ℓ, and out is a function of s. In practice, constant operating power gain circles (for any arbitrary chosen ℓ, conjugately match in to s) or constant available power gain circles (for any arbitrary chosen ...
single-phase bridge rectifiers with current filters
single-phase bridge rectifiers with current filters

... from the output voltage waveform is low and large current or voltage filters are required. A two-pulse rectification can also be achieved using a single-phase midpoint rectifier (M2) which requires obligatorily an oversized line-frequency transformer with two identical secondary windings. Unlike the ...
Motivating Software-Driven Current Balancing in Flexible Voltage-Stacked Multicore Processors
Motivating Software-Driven Current Balancing in Flexible Voltage-Stacked Multicore Processors

... effect while considering a typical Google production datacenter workload mix. From the 17 workloads that they characterize, only 5 are considered latency-insensitive. Furthermore, Reddi and Lee [15] show that running such emerging applications on simple processor cores, while undoubtedly more power ...
Specification Sheet - Elliott Electric Supply
Specification Sheet - Elliott Electric Supply

... Sources of high energy transients include lightning induced surges, power company switching and short circuits. These high energy transients can destroy components instantly. ...
ppt - kaliasgoldmedal
ppt - kaliasgoldmedal

... • In this mode of operation only one converter is switched on at a time • When the converter 1 is switched on, For 1 < 900 the converter 1 operates in the Rectification mode Vdc is positive, Idc is positive and hence the average load power Pdc is positive. • Power flows from ac source to the load P ...
LYTSwitch-4 Family - Power Integrations
LYTSwitch-4 Family - Power Integrations

... connected at its input. This voltage threshold is used for remote ON/OFF control. When a signal is received at the VOLTAGE MONITOR pin to disable the output (VOLTAGE MONITOR pin tied to ground through an optocoupler phototransistor) the LYTSwitch-4 will complete its current switching cycle before th ...
Merlin 200KW-300KW Large Portable Load Bank
Merlin 200KW-300KW Large Portable Load Bank

... The load elements in this Load Bank are cooled by a horizontal forced air system which discharges through the rear of the cabinet. Location of the Load Bank is of prime importance and should be done by trained personnel. It is one of the most critical factors involved in safe operation. The Load Ban ...
Lab Manual Power Electronics (EE460)
Lab Manual Power Electronics (EE460)

... 4. Get part an AC sinusoidal source VSIN and a DC battery VDC from the source.slb library. (Set VSIN amplitude to 11.5 V and VDC to 0V) 5. Get part resistance R from the analog.slb library. 6. Get part diode D1N4148 from the eval.slb library (you may choose a different diode from the PSpice library) ...
Copy of the Market Participant Comment Matrix
Copy of the Market Participant Comment Matrix

... “collector bus” means the low voltage side of any step-up transformers connected to the interconnected electrictransmission system or the electrical system in the City of Medicine Hat where the real power and reactive power produced by any generating units or reactive power resources, or both of the ...
C_201509_Qiteng_Hong_APAP_LoadShedding_Final
C_201509_Qiteng_Hong_APAP_LoadShedding_Final

have  been  applied  in  industrial ... aircrafts and electric vehicle applications with more electrically
have been applied in industrial ... aircrafts and electric vehicle applications with more electrically

... to the MC as voltage-source inverters [6], [7]. For MC systems, great efforts have been made on topics like topologies and modulation strategies [8]-[13]. In comparison, studies on fault diagnosis and fault tolerant strategies are relatively less. Open circuit or short circuit fault of power devices ...
PM1200 power meter - Schneider Electric
PM1200 power meter - Schneider Electric

... comprehensive 3-phase electrical instrumentation and load management facilities in a compact and rugged package. This chapter contains the main operating instructions. The remaining chapters explain the installation and setup steps required before the meter is ready for use, and maintenance and trou ...
IMPORTANT CABLE INFORMATION Significant power loss to the
IMPORTANT CABLE INFORMATION Significant power loss to the

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... Multilevel Converters are a very interesting solution for medium and high voltage applications. Because of its characteristic of synthesize a sinusoidal voltage on several DC levels. The better topology for power quality and transmission systems applications is the cascade multilevel inverters [1, 2 ...
High Voltage Power Supply Technology for Use in Power Feed
High Voltage Power Supply Technology for Use in Power Feed

Effect and Utilization of Common Source Inductance in Synchronous
Effect and Utilization of Common Source Inductance in Synchronous

An Active Decoupling Capacitance Circuit for Inductive Noise
An Active Decoupling Capacitance Circuit for Inductive Noise

... obtain a smaller supply drop for the same amount of explicit decoupling capacitance. Active guard ring circuits, based on the use of active decaps, were proposed in [8] and [9] to suppress substrate noise. In [10], an active decap technique was proposed to reduce crosstalk between digital and analog ...
APP014 - 3 Phase 2 Wattmeter Explained
APP014 - 3 Phase 2 Wattmeter Explained

... the power, if a wattmeter were connected to phase 3 would equal zero as P = IV. This is because although current will be flowing the voltage would be zero. As we know the LineLine voltage is 3 x Line-Neutral Voltage, even before performing some calculations it may be apparent that the power in the 3 ...
MGE Catalog 2003 r7
MGE Catalog 2003 r7

... AC source is available increasing the availability of power to critical loads. Featuring proven pulse width modulation (PWM) technology specifically designed to meet the demanding AC power requirements of today’s electronic equipment, the Topaz S3 provides excellent isolation between AC and DC for m ...
LIU_IONS_Linac3_meeting_19_11_2014
LIU_IONS_Linac3_meeting_19_11_2014

Chapter 2 2 OVERVIEW OF THE FACTORS AFFECTING THE
Chapter 2 2 OVERVIEW OF THE FACTORS AFFECTING THE

... Various parts of the circuit design and fabrication process contribute to the gap between ASIC and custom power. Our analysis of the most significant design factors and their impact on the total power when a chip is active is outlined in Table 2.4. The “typical” column shows the maximum contribution ...
Preparation of Papers for IUST International Journal of Engineering
Preparation of Papers for IUST International Journal of Engineering

Lowering Power at 28 nm with Xilinx 7 Series FPGAs White Paper
Lowering Power at 28 nm with Xilinx 7 Series FPGAs White Paper

... amount of static power consumption is not important. Historically, MPU and GPU class products have used HP type processes. FPGAs followed this lead, with some trade-offs of performance for acceptable power levels. Historically, MPU and GPU class products have used HP (G) type processes at 65 nm and ...
< 1 ... 15 16 17 18 19 20 21 22 23 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report