• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
svc
svc

... A step-down transformer is usually placed between the AC system bus-bar and the low voltage bus-bar to which the thyristor valves are connected. Once the SVC capacity is determined, the best way to design the valve is to use the thyristor current capability at its maximum. Then the minimum necessary ...
Q: What about connecting Power and Ground? Power and Ground
Q: What about connecting Power and Ground? Power and Ground

... always be applied (or at least considered). Here are some important considerations: Power and Sense The DUT power supplies inside of the test system provide programmable Vdd at the DUT board, as well as the sense lines for each supply. The sense lines are joined in surface etch on the DUT board at t ...
DN549 - Powering Altera Arria 10 FPGA and Arria 10 SoC: Tested
DN549 - Powering Altera Arria 10 FPGA and Arria 10 SoC: Tested

... evaluate an FPGA without having to design a complete system. Figures 1 and 2 show Altera’s new 20nm Arria 10 FPGAs and Arria 10 SoCs (System-on-Chip) development boards. These boards are tested and verified by Altera, exemplifying best design practices in layout, signal integrity and power managemen ...
Product Bulletin
Product Bulletin

... energy efficiency and power CBC-8000 control can act as a quality with the CBC-8000 stand-alone, one-way, or twocapacitor bank control and twoway communicating device way communications. Eaton’s with advanced distribution Cooper Power Systems Smart automation features and Grid technology uses Volt/V ...
Zero Sequence Harmonics - Hammond Power Solutions
Zero Sequence Harmonics - Hammond Power Solutions

... High levels of third order, zero sequence harmonics are principally the by-product of switch mode power supply technology, which is used in modern office equipment and lighting systems as well as in virtually all other low power electronic devices. These power supplies are efficient, small, light we ...
Super ECO Mode - CSF ELEKTRO sro
Super ECO Mode - CSF ELEKTRO sro

Ohm`s Law and Electrical Power
Ohm`s Law and Electrical Power

... 2) What current flows in a circuit with a potential difference of 12v and a resistance of 25 Ω? 0.48 A 3) What is the resistance of a circuit with a voltage of 45v and a current of 5 A? 9 Ω 4) A circuit has 80 Ω of resistance. What voltage is required to push 25 mA through it? (convert mA to A) 2 v ...
Technical Specifications
Technical Specifications

... You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator: http://ucspowercalc.cisco.com ...
POWER PULSE pe86CB-20-3-9-S-GD_e.indd.indd - Hendor
POWER PULSE pe86CB-20-3-9-S-GD_e.indd.indd - Hendor

... Clear and user friendly menu navigation via well structured pull down menus ...
single phase unified power flow controller without dc link
single phase unified power flow controller without dc link

... In this mode of operation, the series voltage injected by the SSSC is a two dimensional quantity with both quadrature and in phase components relative to the line current, and it is therefore able to independently control both the real and reactive power flow down the transmission line. Depending on ...
Aug 2010 - Pump Ed 101
Aug 2010 - Pump Ed 101

... This plot shows the flow of voltage (blue), current (red) and power (green) in a simple resistive circuit such as the one seen in Figure 1. In a purely resistive circuit, voltage and current rise and fall together in a synchronous fashion. The reason this occurs is that a resistance continuously opp ...
IOSR Journal of Electrical And Electronics Engineering (IOSRJEEE)
IOSR Journal of Electrical And Electronics Engineering (IOSRJEEE)

OR3425552561
OR3425552561

... synchronism with the AC system. The synchronism of the three-phase output voltage with the transmission line voltage has to be performed by an external controller. The amount of desired voltage across STATCOM, which is the voltage reference, Uref, is set manually to the controller. The voltage contr ...
Abstract - theelectromech.in
Abstract - theelectromech.in

School Service - Marshall County REMC
School Service - Marshall County REMC

... lines, wiring and other electrical equipment beyond the metering point is considered the distribution system of the member and shall be furnished and maintained by the member. The metering equipment shall he furnished and maintained by the REMC. When primary metering is required, the metering equipm ...
Diesel Generator set QSK23 series engine
Diesel Generator set QSK23 series engine

... starting capability with low reactance 2/3 pitch windings; low waveform distortion with non-linear loads, fault clearing shortcircuits capability, and class H insulation. ...
Final Presentation
Final Presentation

The asynchronous machine model
The asynchronous machine model

... The rotor can be made with or without terminals to the rotor windings. The rotor with terminals has the possibility to connect a resistor in the rotor circuit or to connect a wye-delta switch to reduce motor starting currents. The rotor without terminals can be produced with windings, consisting of ...
Complete Paper - Research Publish Journals
Complete Paper - Research Publish Journals

... It is an undisputed fact that the supply of electric power in Nigeria and most developing countries of the world are erratic in nature. This is however unhealthy for most processes or systems which are dependent on electric power. Hence an alternative electricity source is essential for improved eff ...
Word - University of California, Berkeley
Word - University of California, Berkeley

... approaches infinity? Why is the energy-delay product for N=1 different than that of a standard CMOS inverter (neglecting short circuit current and static dissipation)? ...
Ampzilla review from Audio Magazine
Ampzilla review from Audio Magazine

... wave into a 1 pF load and a 2O-kHz sine wave into eight ohms with a 2 dB input overdrive where the input is increased 2 dB over the value that just causes the output to begin to clip The large signal square wave indicates the amplifier's ability to deliver in excess of 10 amps into a'l pF load. This ...
O A
O A

... Generation, transmission and distribution are the main parts of the power system. The electricity is generated in the power station, which is installed with generators, control and instrumentation equipments, switchgears and other associated plants and equipment for quality power distribution (Hanna ...
App Note 500 - Calculating Capacitor Charge Time - TDK
App Note 500 - Calculating Capacitor Charge Time - TDK

... 5, and as long as the required charge voltage and load capacitance is known then it is possible to calculate charge time using equation 6 (the charge balance formula). ...
C 325BEE Stereo Integrated Amplifier
C 325BEE Stereo Integrated Amplifier

Power Flow Control by Use of Phase
Power Flow Control by Use of Phase

... load side is always equal to the voltage magnitude at the source side, independent from the phase angle [4]. Quadrature non-symmetric devices add a quadrature voltage to the input voltage. The output voltage is the vector sum of these two perpendicular voltages (therefore the output voltage is boost ...
< 1 ... 175 176 177 178 179 180 181 182 183 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report