• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Liebert Precision Power Center Packaged Power Distribution For Higher Power Quality
Liebert Precision Power Center Packaged Power Distribution For Higher Power Quality

... © 2002 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. ® Liebert and the Liebert logo are registered trademarks of the Liebert Corporation. ...
POWER ELECTRONICS AND ITS CHALLENGES
POWER ELECTRONICS AND ITS CHALLENGES

Fuzzy System for the Detection of Power Quality Performance on
Fuzzy System for the Detection of Power Quality Performance on

VAM90100P User Manual
VAM90100P User Manual

... Zhengzhou Minghe Electronic Technology Co., Ltd ...
CALTRAP™
CALTRAP™

... Remove covers and visually check contacts for signs of wear and excessive arcing every six (6) months. Energize each contactor with the controller in "manual" mode to ensure proper operation. How to Check Fuses: Trouble: Fuse light is illuminated.  This indicates that a fuse is blown. Typically, po ...
POWER FACTOR TESTING WHAT IS IT ?
POWER FACTOR TESTING WHAT IS IT ?

...  The tests performed and analysis of results indicates that TCF being average correction values can introduce error varying from as little as 2% to as high as 92% on the specimen tested  The analysis was performed on three different insulations of a single transformer only. Other transformers with ...
analysis of technical losses in electrical power system(nigerian
analysis of technical losses in electrical power system(nigerian

... Loss factor = (0.3 × Load factor) + (0.7) (Load factor) 2 Where the load factor is the ratio of average load to peak load. 9. SYSTEM PARAMETERS When current flows in a transmission line, the characteristics exhibited are explained in terms of magnetic and electric field interaction. The phenomenon t ...
Lecture notes-in-progress for the "Electromechanical grid"
Lecture notes-in-progress for the "Electromechanical grid"

... – KVL is analogous to saying that “what goes up, must come down.” If we trace the path of a baseball through the course of a game, for example, the total amount of energy gained/lost by going up and down must be zero. • KVL, KCL and Ohm’s law together give power grids unique properties that make flo ...
Price Discovery in Dynamic Power Markets with Low-Voltage Distribution-Network Participants Elli Ntakou
Price Discovery in Dynamic Power Markets with Low-Voltage Distribution-Network Participants Elli Ntakou

... substation real energy price, then it will be providing reserves, and thus the opportunity cost for reactive power production will be associated with the clearing price for reserves at the substation. Otherwise, if the substation generator has smaller fuel cost than the substation real energy price, ...
- Jntu World
- Jntu World

... Downloaded From JNTU World ...
KFD2-CD-Ex1.32-** Current/Voltage Driver Connection Assembly
KFD2-CD-Ex1.32-** Current/Voltage Driver Connection Assembly

Industrial / Power
Industrial / Power

Keysight Technologies Zero Volt Electronic Load
Keysight Technologies Zero Volt Electronic Load

AX8052 Power On Reset
AX8052 Power On Reset

... Figure 2 shows a temporary loss of power waveform. In this scenario, if the VDD_IO voltage does not return to below 0.1 V before reapplying power again, but lingers in the range of approximately 0.45 V to 0.7 V and the rise time is lower than 3.3 V/ms then external reset circuitry or an external res ...
BR044426429
BR044426429

Microwave Integrated Circuits (MIC)
Microwave Integrated Circuits (MIC)

External Power SupplyTest Method
External Power SupplyTest Method

Compact Power Line - Mouser Electronics
Compact Power Line - Mouser Electronics

... The CP1800AC52 Front-End Power Supplies in the Compact Power Line platform are specifically designed to operate as an integral part of a complete distributed power system. The high-density, front-toback airflow rectifier is designed for minimal space utilization and is highly expandable for future g ...
Small, silent, lightweight
Small, silent, lightweight

... It may seem a matter of course. Circuit protectors. Power distribution systems. Admittedly, they are genuine technical challenges. But do these products really have such a high priority? We at E-T-A know that there is only one possible answer to this question: »Yes!« Because E-T-A is always protecti ...
A Novel Reduced Switch Power Quality Improvement for Current Harmonic Compensation and Voltage Sag Mitigation Using Model Predictive Control
A Novel Reduced Switch Power Quality Improvement for Current Harmonic Compensation and Voltage Sag Mitigation Using Model Predictive Control

... modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as mo ...
View/Open - Library@Atmiya
View/Open - Library@Atmiya

Hoefer Power Supply
Hoefer Power Supply

... When connecting high-voltage leads to the power supply, use your right hand only. Because of the potential for lethal shock across the chest do not use both hands to plug in (or unplug!) power supply leads. Also, make sure your left hand is not touching anything that would ground you. 3 Turn on the ...
Download
Download

Direct-current supply system with an uninterruptible power supply
Direct-current supply system with an uninterruptible power supply

PROPER OPERATION OF STEP VOLTAGE REGULATORS IN THE
PROPER OPERATION OF STEP VOLTAGE REGULATORS IN THE

... real power flow through the regulator bank is from right to left (Generator to Substation). With normal bi-directional sensing, the regulator would therefore reverse its direction of operation and attempt to regulate the voltage on its source side, position (1). The Substation voltage is effectively ...
< 1 ... 147 148 149 150 151 152 153 154 155 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.