• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
double stator winding induction generator for renewable energy
double stator winding induction generator for renewable energy

AN OVERVIEW OF UNITY POWER FACTOR POWER SUPPLY
AN OVERVIEW OF UNITY POWER FACTOR POWER SUPPLY

Power Consumption
Power Consumption

... Most installations do not know the input watts without finding out from the pump manufacturer. Another method is given if the known is duty cycle, voltage, amperage, and power factor. First, we must convert the electrical readings to an input power (kilowatt): input power = (voltage) * (amperage) * ...
FX Series - Glassman High Voltage
FX Series - Glassman High Voltage

... Tight Regulation. Voltage regulation is better than 0.005% for allowable line and load variations. Current regulation is better than 0.05% from short circuit to rated voltage. Front Panel Controls. Separate 10-turn controls with locking vernier dials are used to set voltage and current levels. A hig ...
generator using instantaneous power control
generator using instantaneous power control

Optimal electrical parameters
Optimal electrical parameters

1) Voltage, current, AC, DC, regulated, unregulated - what do
1) Voltage, current, AC, DC, regulated, unregulated - what do

... - what is the type of adapter jack and its polarity? - how much current it draws? The answer to the first three questions is in most cases 9V DC with centre negative DC-plug. If that is the case for all your pedals you are lucky. You just have to add the current figures for all your pedals and then ...
NAG8152-DPM3 Netzanschaltgerät
NAG8152-DPM3 Netzanschaltgerät

... On the display, various information pages can be viewed by using the left and right buttons. The test voltage and power can be seen in these pages. The correct installation of the CTs can only be verified by checking the power factor only if the current flows. If this is zero, then the CT has been i ...
StatCom
StatCom

... location of this bus is selected to be either Bus A or Bus B. As can be seen from Fig. 3, two-GTO based six-pulse voltage source inverters represent the STATCOM used in this particular study. The voltage source inverters are connected to the ac system through two 80 MVA coupling transformers, and li ...
- Krest Technology
- Krest Technology

... power loss due to leakage inductance. Recently, DC micro-grid gets major importance because of the significant increase in DC loads and demand of high quality power. These DC loads require different voltage levels based on their power ratings. Photo voltaic source (PV) is one of the prime source of ...
On Current and Power Injection Models for Angle
On Current and Power Injection Models for Angle

... u (u ∈ Rnu ) the vector of discrete variables, t (t ∈ R+ ) the time, f (f : Rnx × Rny × Rnp × Rnu × R+ 7→ Rnx ) are the differential equations, and g (g : Rnx ×Rny ×Rnp ×Rnu ×R+ 7→ Rny ) are the algebraic equations. If discrete variables u are substituted for if-then rules, (1) becomes an hybrid dyn ...
sample questions - Department of Electrical Engineering, IIT
sample questions - Department of Electrical Engineering, IIT

... 2. A single phase full bridge diode rectifier operates from a 220V, 50 Hz single phase supply and delivers power to a 50 Ω resistance connected across the output capacitor. The voltage across the output capacitor may be assumed to be ripple free. i) Find out the value of the filter inductor (with ne ...
power amplifier
power amplifier

... Typical load values range from 300W (for transmission antennas) to 8W (for audio speaker). Although these load values do not cover every possibility, they do illustrate the fact that power amplifiers usually drive lowresistance loads. Typical output power rating of a power amplifier will be 1W or hi ...
EE14 paper1
EE14 paper1

... of a static synchronous compensator (STATCOM) and a static synchronous series compensator (SSSC), both are linked via a common dc link, to permit bidirectional flow of active power between output terminals of the SSSC and the STATCOM as shown in Fig. 1. The UPFC converters can independently generate ...
Critical load protection from the world`s largest three phase UPS
Critical load protection from the world`s largest three phase UPS

... topology (the only recognized true “on-line” topology for use in high reliability applications) uses the rectifier & inverter to isolate devices on the UPS output from the dangers of raw utility power. Other conversion topologies allow poor power conditions, such as low voltage surges, to travel thr ...
Speed Control of PMBLDC Motor Using PFC Cuk Converter
Speed Control of PMBLDC Motor Using PFC Cuk Converter

power quality improvement in grid connected system using
power quality improvement in grid connected system using

Low-Volume PFC Rectifier Based on Non
Low-Volume PFC Rectifier Based on Non

PDF
PDF

... changed: more and more equipment is sensitive to very short duration events, and more and more customers (domestic as well as industrial) view short interruptions as a serious imperfection of the supply. The quality of the power is effected by many factors like harmonic contamination, due to the inc ...
AR01415591564
AR01415591564

Low Power Design of VLSI Circuits
Low Power Design of VLSI Circuits

... that lower the quality of the resonator. In this circuit the energy moves back and forth between L1 and the C_CLOCK, which causes a sinusoid oscillation with a resonant frequency f. C2 must be large enough to store excess energy and not interfere with resonance of the clock capacitance.  IBM used a ...
Modeling and Simulation of SVC for Reactive
Modeling and Simulation of SVC for Reactive

Cct component
Cct component

Pierquet, B.J. and D.J. Perreault, “A Single-Phase Photovoltaic Inverter Topology with a Series-Connected Power Buffer,” 2010 IEEE Energy Conversion Congress and Exposition , pp. 2811-2818, Sept. 2010.
Pierquet, B.J. and D.J. Perreault, “A Single-Phase Photovoltaic Inverter Topology with a Series-Connected Power Buffer,” 2010 IEEE Energy Conversion Congress and Exposition , pp. 2811-2818, Sept. 2010.

... One method to understand the solution(s) for the unknown angles is to consider each power transfer constraint from (7) separately. To calculate a valid set of solutions for each, a simple brute-force map of the phase-space (θB , θC ) is performed to determine the resulting power transfer at each pha ...
- PAT tel doo
- PAT tel doo

... cross section is needed in case of long distances. The cross section can be increased up to 32 mm2 (2 x 16 mm2). Further, the second power entry is needed when using 2 separate power supplies, one for RRH 1 3 and the other for RRH 4 6. POWER EXIT The PTTA box exits are compatible with shielded 2 wir ...
< 1 ... 140 141 142 143 144 145 146 147 148 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report