• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
T.E. - Electrical Electronics Engg.
T.E. - Electrical Electronics Engg.

... Theory: 100 Mark Term Work: 25 Mark POE: 50 Mark --------------------------------------------------------------------------------------------------------------------Objectives: • To study of 3 phase and 1 phase AC motors. SECTION –I 1. SYNCHRONOUS GENERATOR: Construction, Principle of operation, EMF ...
Computer Maintenance
Computer Maintenance

pedal power - Voodoo Lab
pedal power - Voodoo Lab

... The Voodoo Lab Pedal Power has eight DC output jacks. These accept barrel type connectors. Notice that each of your DC power cables have a barrel connector on at least one end. The other end has either another identical barrel connector, a 5.5x2.5mm RED barrel, a 3.5mm mini-plug, or a battery snap. ...
LAB#5 - SIUE
LAB#5 - SIUE

Instructions - Precision Lighting
Instructions - Precision Lighting

... adjustable coupler [BT-513] power bolt [BT-507] end cap [BT-808] ...
AND9056 - High Performance IGBT for Induction Heating
AND9056 - High Performance IGBT for Induction Heating

... production of these IH cookers. The market for induction heating applications will grow tremendously, if production costs can be reduced, and more efficient IH cookers can be developed. Several parameters are to be considered when optimizing an IGBT. These include physical device properties such as ...
RA06H8285M 数据资料DataSheet下载
RA06H8285M 数据资料DataSheet下载

... Please also pay attention to information published by Mitsubishi Electric Corporation by various means, including the Mitsubishi Semiconductor home page (http://www.MitsubishiElectric.com/). •When using any or all of the information contained in these materials, including product data, diagrams, cha ...
Delivering Clean and Pure Power
Delivering Clean and Pure Power

... transmission system limitations. However, power electronics are alive and well in useful applications to overcome distribution system problems. Power electronics has three faces in power distribution: one that introduces valuable industrial and domestic equipment; a second one that creates problems; ...
TI/National LED Lighting Presentation
TI/National LED Lighting Presentation

... • MR-16 Replacement • Automotive Lighting ...
electrical power engineering
electrical power engineering

... has to be generated at the same time the consumer needs it. The generation of electrical energy is performed almost exclusively by means of high power synchronous machines, or alternators, whose construction design depends on the type of drive, which can normally be steam, gas or water. Then, if the ...
PP101007-a - Indico
PP101007-a - Indico

Impact of Wind Turbine Generating Units on Power System Voltage
Impact of Wind Turbine Generating Units on Power System Voltage

... amount of distributed generation raises a number of issues, for example, voltage profiles change along the network, depending on how much power is produced and consumed at that system level. This paper presents impact of wind turbine generating units to variations of voltage and power losses in dist ...
A radiation-tolerant LDO voltage regulator for HEP - Indico
A radiation-tolerant LDO voltage regulator for HEP - Indico

...  Commercial converters do not target this environment because they are not radiation tolerant and use ferromagnetic material that saturate at this external magnetic field. ...
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.4, pp. 1884-1890
International Electrical Engineering Journal (IEEJ) Vol. 6 (2015) No.4, pp. 1884-1890

... controller whose derivative and integral is fraction rather than integer, extending this derivative and integral order from integer to fractional provide more flexibility in design of the controller thereby controlling the wide range of dynamics. In fractional order ( PI  D ) besides integral ( K ...
RA03M8087M
RA03M8087M

... By the gate voltage (VGG). When the gate voltage is close to zero, the RF input signal is attenuated up to 60 dB and only a small leakage current flows from the battery into the drain. Around VGG=2.5V, the output power and drain current increases substantially. Around VGG=3V (typical) to VGG=3.5V (m ...
Boosting ATCA Hardware Platform Management
Boosting ATCA Hardware Platform Management

Switched-mode power supply
Switched-mode power supply

... power transistors and diodes as well as a power transformer, inductors, and filter capacitors. Some design complexities present (reducing noise/interference; extra limitations on maximum ratings of transistors at high switching speeds) not found in linear regulator circuits. ...
DIGITAL POWER METER MODEL 66201/66202
DIGITAL POWER METER MODEL 66201/66202

... A Window Mode method that calculates all data within the user-defined window time (Tw) is recommended. So, users can get a real average value without any data lose. An accumulated energy approach method (i.e. integration mode) for power measurements is also provided. This integration mode calculates ...
experiment 5 - UniMAP Portal
experiment 5 - UniMAP Portal

... it equals the voltage across either winding (EAB and EBC). The third winding is then connected in series, and the voltage across the series combination of the three windings is measured to confirm that it is zero before delta is closed, as shown in Figure 5-4 (b). This is extremely important for a d ...
7 Practices to Prevent Damaging Power Meters and Sensors
7 Practices to Prevent Damaging Power Meters and Sensors

... can measure, which is specified as the frequency range. If the power sensor measures peak power, the video bandwidth will also be stated. In fine print will be some warnings and reminders. Do not exceed the values provided in the specifications guide or as indicated by the yellow warning labels on t ...
Modeling of Load During and After System Faults Based on Actual
Modeling of Load During and After System Faults Based on Actual

... power systems are being forced to be heavily loaded. In addition, older generators in urban areas are being decommissioned to save the high operation and maintenance costs. As a consequence, voltage instability problems are attracting more and more attention in power system operation, planning, and ...
Comparison of advantages and disadvantages of electronic
Comparison of advantages and disadvantages of electronic

... The application of mechanical contacts parallel to the semiconductor will minimise the onstate power loss of semiconductors. Combinations like a TRIAC in parallel to a contactor are especially known for switching AC circuits. The on-resistance is determined by the low contact resistance of the mech ...
Types of DR Island Systems - IEEE Standards working groups
Types of DR Island Systems - IEEE Standards working groups

GZ3612511256
GZ3612511256

... II. RELEVANT WORK Mike Papadimitriou [1], in his work used LM317 for varying DC power supply. It’s a 3−terminal positive voltage regulator which is changeable. It can give current of 1.5A. Its output voltage cans changer over interval of 1.2 V to 37 V. For fixing the output voltage in this regulator ...
OWNERS MANUAL WB-600-IPVCE-12 KEY FEATURES
OWNERS MANUAL WB-600-IPVCE-12 KEY FEATURES

... This Wattbox™ component requires a properly grounded outlet for safety and to protect connected equipment. If you’re not sure if your home’s electrical wiring is properly grounded, have it checked by a qualified electrician. If any rooftop devices such as satellite dishes, antennas, or any other com ...
< 1 ... 110 111 112 113 114 115 116 117 118 ... 250 >

Power factor



In electrical engineering, the power factor of an AC electrical power system is defined as the ratio of the real power flowing to the load to the apparent power in the circuit, and is a dimensionless number in the closed interval of -1 to 1. A power factor of less than one means that the voltage and current waveforms are not in phase, reducing the instantaneous product of the two waveforms (V x I). Real power is the capacity of the circuit for performing work in a particular time. Apparent power is the product of the current and voltage of the circuit. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power will be greater than the real power. A negative power factor occurs when the device (which is normally the load) generates power, which then flows back towards the source, which is normally considered the generator.In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system, and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor.Linear loads with low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report