Hardware Development Guide for i.MX 6QuadPlus, 6Quad
... NXP makes no warranty, representation, or guarantee regarding the suitability of its products for any particular purpose, nor does NXP assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation ...
... NXP makes no warranty, representation, or guarantee regarding the suitability of its products for any particular purpose, nor does NXP assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation ...
LE25U20AFD Serial Flash Memory 2 Mb (256K x 8)
... There are two read commands, the 4 bus cycle read command and 5 bus cycle read command. Consisting of the first through fourth bus cycles, the 4 bus cycle read command inputs the 24-bit addresses following (03h), and the data in the designated addresses is output synchronized to SCK. The data is out ...
... There are two read commands, the 4 bus cycle read command and 5 bus cycle read command. Consisting of the first through fourth bus cycles, the 4 bus cycle read command inputs the 24-bit addresses following (03h), and the data in the designated addresses is output synchronized to SCK. The data is out ...
Riello UPS Dialog Dual DLD Series 5000-6000 Manual
... f) Do not switch the UPS on if there is any leak of liquid, or if a residual white powder is noted. g) Do not allow water, liquids in general and/or other foreign bodies to get into the UPS. h) In the event of dangerous conditions switch the UPS off with the switch located on the front panel and ope ...
... f) Do not switch the UPS on if there is any leak of liquid, or if a residual white powder is noted. g) Do not allow water, liquids in general and/or other foreign bodies to get into the UPS. h) In the event of dangerous conditions switch the UPS off with the switch located on the front panel and ope ...
RSAW_v1.0-VAR-002-AB-1.1b Reliability Standard Audit Worksheet Generator Operation for Maintaining Network Voltages
... (a) the legal owner of a generating unit, including those that operate as a synchronous condenser, that: (i) is not part of an aggregated generating facility; (ii) has a maximum authorized real power rating greater than four point five (4.5) MW; and (iii) is directly connected to either the transmis ...
... (a) the legal owner of a generating unit, including those that operate as a synchronous condenser, that: (i) is not part of an aggregated generating facility; (ii) has a maximum authorized real power rating greater than four point five (4.5) MW; and (iii) is directly connected to either the transmis ...
Measurement and Filtering of Output Noise of DC
... the primary and secondary windings, which forms a high ratio surface mount ceramic capacitors. This should reduce the CM capacitive divider with the output-to-case parasitics. Much of spectrum magnitude but may increase the DM noise spectrum, the high level pulses at the primary side power MOSFET dr ...
... the primary and secondary windings, which forms a high ratio surface mount ceramic capacitors. This should reduce the CM capacitive divider with the output-to-case parasitics. Much of spectrum magnitude but may increase the DM noise spectrum, the high level pulses at the primary side power MOSFET dr ...
Technical Requirements for Subsea High Voltage Direct
... Subsea cable connectors: AC vs. DC Insulation AC Insulation DC Insulation Field is capacitive graded, i.e., determined by dielectric constant, which for typical ac insulation, is nearly independent of field & temperature : ...
... Subsea cable connectors: AC vs. DC Insulation AC Insulation DC Insulation Field is capacitive graded, i.e., determined by dielectric constant, which for typical ac insulation, is nearly independent of field & temperature : ...
Ch5LectureSlides
... ix = ix’+ix’’=2 + (−0.6) = 1.4 A Copyright © 2013 The McGraw-Hill Companies, Inc. Permission required for reproduction or display. ...
... ix = ix’+ix’’=2 + (−0.6) = 1.4 A Copyright © 2013 The McGraw-Hill Companies, Inc. Permission required for reproduction or display. ...
2.1 Dynamic Power Management (DPM)
... the dynamic power consumption of the processor. But, this results in more static power consumption and more energy consumption of peripheral devices since the active periods of peripheral devices are also lengthened to reduce the time duration for shutdown or idle mode operation. On the other hand, ...
... the dynamic power consumption of the processor. But, this results in more static power consumption and more energy consumption of peripheral devices since the active periods of peripheral devices are also lengthened to reduce the time duration for shutdown or idle mode operation. On the other hand, ...
Guide to Using the Multimeter
... The selector is used to choose the function (voltmeter, ammeter or ohmmeter) and the most appropriate range for the measurement. The choice of function determines the section in which the selector must be positioned to take the measurement. The choice of range determines the exact position of the se ...
... The selector is used to choose the function (voltmeter, ammeter or ohmmeter) and the most appropriate range for the measurement. The choice of function determines the section in which the selector must be positioned to take the measurement. The choice of range determines the exact position of the se ...
Design Considerations for Electrical Fast Transient (EFT)
... repetitive fast transients and the necessary test methods for systems. The EFT waveform, as defined by the IEC 61000-4-4 standard, is intended to be used by manufacturers to test the performance of equipment when subjected to fast transients. Primarily, the testing involves injection of EFT pulses i ...
... repetitive fast transients and the necessary test methods for systems. The EFT waveform, as defined by the IEC 61000-4-4 standard, is intended to be used by manufacturers to test the performance of equipment when subjected to fast transients. Primarily, the testing involves injection of EFT pulses i ...
Medium Voltage Motor Insulation System
... stable material for the leads. The leads are made of flexible copper strands coated with Silicon Rubber insulation rated 200 deg. C. For increased durability the leads also have an additional sheathing of braided glass over the Silicon insulation to protect from damage. End-Turn Bracing: Every time ...
... stable material for the leads. The leads are made of flexible copper strands coated with Silicon Rubber insulation rated 200 deg. C. For increased durability the leads also have an additional sheathing of braided glass over the Silicon insulation to protect from damage. End-Turn Bracing: Every time ...
Siemens STEP 2000 Course
... element segments can melt simultaneously, which helps remove the load from the source voltage quickly. Short-circuit current is typically cut off in less than half a cycle, before it can reach its full value. ...
... element segments can melt simultaneously, which helps remove the load from the source voltage quickly. Short-circuit current is typically cut off in less than half a cycle, before it can reach its full value. ...
SPC560B4x/5x, SPC560C4x/5x, SPC560B54/6x, SPC560D30/40
... The external reset signal (pulse) on the NRST pin must be greater than WNFRST (500 ns). Pulses less than WFRST (50 ns) are ignored. Any pulse between WFRST and WNFRST may or may not generate an internal reset. A noise applied on the reset signal might wrongly put the device in reset. In order to avo ...
... The external reset signal (pulse) on the NRST pin must be greater than WNFRST (500 ns). Pulses less than WFRST (50 ns) are ignored. Any pulse between WFRST and WNFRST may or may not generate an internal reset. A noise applied on the reset signal might wrongly put the device in reset. In order to avo ...
laboratory manual
... As you work through the laboratory course you should take comprehensive notes in your lab book (see above). Once you have completed taking measurements, all of your measurements, calculations, graphical work and conclusions for laboratory experiments 1–3 & 5 must be entered directly onto the separat ...
... As you work through the laboratory course you should take comprehensive notes in your lab book (see above). Once you have completed taking measurements, all of your measurements, calculations, graphical work and conclusions for laboratory experiments 1–3 & 5 must be entered directly onto the separat ...
Halo Integrated
... mounting in a standard 19” equipment rack, you must use the Parasound HRA 3 rack mount kit (purchased separately). The HRA 3 kit includes four bolts and eight plastic washers with raised “shoulders.” Slide one washer onto each mounting bolt with its raised shoulder pointing toward the panel hole. In ...
... mounting in a standard 19” equipment rack, you must use the Parasound HRA 3 rack mount kit (purchased separately). The HRA 3 kit includes four bolts and eight plastic washers with raised “shoulders.” Slide one washer onto each mounting bolt with its raised shoulder pointing toward the panel hole. In ...
Impedance Measurements, Computations and their
... Most other impedances have to be computed. Several codes have been developed over the years which use basically two methods. The first works in frequency domain and calculates modes of cavity-like objects giving their resonant frequencies !r with the normalized shunt impedance Rs=Q and in most cases ...
... Most other impedances have to be computed. Several codes have been developed over the years which use basically two methods. The first works in frequency domain and calculates modes of cavity-like objects giving their resonant frequencies !r with the normalized shunt impedance Rs=Q and in most cases ...
Opto-isolator
In electronics, an opto-isolator, also called an optocoupler, photocoupler, or optical isolator, is a component that transfers electrical signals between two isolated circuits by using light. Opto-isolators prevent high voltages from affecting the system receiving the signal. Commercially available opto-isolators withstand input-to-output voltages up to 10 kV and voltage transients with speeds up to 10 kV/μs.A common type of opto-isolator consists of an LED and a phototransistor in the same opaque package. Other types of source-sensor combinations include LED-photodiode, LED-LASCR, and lamp-photoresistor pairs. Usually opto-isolators transfer digital (on-off) signals, but some techniques allow them to be used with analog signals.