
power_supply_and_cables
... • Assume efficiency 70% (I think I measured it once on STAR SSD MPOD supplies; datasheet doesn’t say, we could inquire of course, but this is roughly about right figure) • PS input AC power per boardstack is 305.3W • PS input AC power per crate 3.05kW • For 200VAC line voltage, input current 15.25A ...
... • Assume efficiency 70% (I think I measured it once on STAR SSD MPOD supplies; datasheet doesn’t say, we could inquire of course, but this is roughly about right figure) • PS input AC power per boardstack is 305.3W • PS input AC power per crate 3.05kW • For 200VAC line voltage, input current 15.25A ...
Pulse-Width Modulation Control Circuits
... comparator has a fixed offset that provides approximately 5% dead time. The on-chip oscillator can be bypassed by terminating RT to the reference output and providing a sawtooth input to CT, or it can drive the common circuits in synchronous multiple-rail power supplies. The uncommitted output trans ...
... comparator has a fixed offset that provides approximately 5% dead time. The on-chip oscillator can be bypassed by terminating RT to the reference output and providing a sawtooth input to CT, or it can drive the common circuits in synchronous multiple-rail power supplies. The uncommitted output trans ...
Pulse-Width Modulation Control Circuits
... comparator has a fixed offset that provides approximately 5% dead time. The on-chip oscillator can be bypassed by terminating RT to the reference output and providing a sawtooth input to CT, or it can drive the common circuits in synchronous multiple-rail power supplies. The uncommitted output trans ...
... comparator has a fixed offset that provides approximately 5% dead time. The on-chip oscillator can be bypassed by terminating RT to the reference output and providing a sawtooth input to CT, or it can drive the common circuits in synchronous multiple-rail power supplies. The uncommitted output trans ...
Power monitoring oversampling terminal for alternating voltages up
... up to 50 µs and then passed on to the control system. The control system has sufficient computing power for true RMS or performance calculations and complex custom algorithms based on the measured voltages and currents. Through the oversampling principle, the terminal is able to measure at significa ...
... up to 50 µs and then passed on to the control system. The control system has sufficient computing power for true RMS or performance calculations and complex custom algorithms based on the measured voltages and currents. Through the oversampling principle, the terminal is able to measure at significa ...
Technical Justification for the CompactRIO
... PLC A Programmable Logic Controller (PLC) is “A specialized device used to provide high-speed, low-level control of a process. It is programmed using LD or some form of structured language, so that engineers can program it. PLC hardware typically costs a lot of money, and often has very good redunda ...
... PLC A Programmable Logic Controller (PLC) is “A specialized device used to provide high-speed, low-level control of a process. It is programmed using LD or some form of structured language, so that engineers can program it. PLC hardware typically costs a lot of money, and often has very good redunda ...
Pre-lab4 Problems
... Web Site: http://www.national.com/ds/LF/LF155.pdf (there is a link from the 3330 web page and a copy in the lab). Verify that the following values are reasonable approximations to use in solving the problems. Identify your source of each item by quoting the graph or table number and page number. DC ...
... Web Site: http://www.national.com/ds/LF/LF155.pdf (there is a link from the 3330 web page and a copy in the lab). Verify that the following values are reasonable approximations to use in solving the problems. Identify your source of each item by quoting the graph or table number and page number. DC ...
Analog-Digital Conversion
... the capacitor voltage starts at zero and is charged for a set time by the output voltage of a sample-and-hold circuit. the capacitor is then switched to a known negative voltage reference, and charged in the opposite direction until it reaches zero volts again. this second charge is timed with a dig ...
... the capacitor voltage starts at zero and is charged for a set time by the output voltage of a sample-and-hold circuit. the capacitor is then switched to a known negative voltage reference, and charged in the opposite direction until it reaches zero volts again. this second charge is timed with a dig ...
Series 7000 Analog Electronic Controls, Selection Guide - Enviro-Tec
... to the minimum flow limit set at the thermostat. The electronic controller modulates the air valve actuator from minimum flow to maximum flow (also set at the thermostat) to provide cooling as necessary to maintain space temperature. As the actual airflow approaches airflow setpoint, the actuator co ...
... to the minimum flow limit set at the thermostat. The electronic controller modulates the air valve actuator from minimum flow to maximum flow (also set at the thermostat) to provide cooling as necessary to maintain space temperature. As the actual airflow approaches airflow setpoint, the actuator co ...
The PWM Control of the Three-phase Induction Motor Ping Wei
... three-phase induction motor. It is by adjusting the pulse width and the pulse duty ratio to regulate the average voltage. The PWM technology [7], accompanied by the development of power electronic devices, has a good development and currently has matured. By using the PWM technique, the inverter out ...
... three-phase induction motor. It is by adjusting the pulse width and the pulse duty ratio to regulate the average voltage. The PWM technology [7], accompanied by the development of power electronic devices, has a good development and currently has matured. By using the PWM technique, the inverter out ...
Chapter 1: DESIGN PROCESS
... This chapter addresses the components of a building electrical system that handle and condition power. Options for incoming electrical service are reviewed. Such service, overhead or underground, must comply with the National Electrical Code, applicable local code requirements, and requirements of t ...
... This chapter addresses the components of a building electrical system that handle and condition power. Options for incoming electrical service are reviewed. Such service, overhead or underground, must comply with the National Electrical Code, applicable local code requirements, and requirements of t ...
Dr. Tommy Morris, Mississippi State University
... Intercepting a password -> bad Intercepting a password file -> worse Intercepting ICS data from an RTU. Is that bad? ...
... Intercepting a password -> bad Intercepting a password file -> worse Intercepting ICS data from an RTU. Is that bad? ...
Document
... includes fundamental system routines, used for starting the processor after the power has been switched on. Additionally, there is the operating system in the case of programmable logic controllers, which is generally stored in a ROM, a read-only memory, or in the EPROM. Firmware is the software par ...
... includes fundamental system routines, used for starting the processor after the power has been switched on. Additionally, there is the operating system in the case of programmable logic controllers, which is generally stored in a ROM, a read-only memory, or in the EPROM. Firmware is the software par ...
Document
... mechatronics system. Transducers sense physical phenomenon such as rise in temperature and convert the measurand into an electrical signal viz. voltage or current. However these signals may not be in their appropriate forms to employ them to control a mechatronics system. Figure 2.6.1 shows various ...
... mechatronics system. Transducers sense physical phenomenon such as rise in temperature and convert the measurand into an electrical signal viz. voltage or current. However these signals may not be in their appropriate forms to employ them to control a mechatronics system. Figure 2.6.1 shows various ...
Digital Systems: Combinational Logic Circuits
... Step 7: Form the ORed sum of all the terms generated by each loop. ...
... Step 7: Form the ORed sum of all the terms generated by each loop. ...
Slides - Roy Featherstone
... Department of Information Engineering, Research School of Information Sciences and Engineering, The Australian National University. ...
... Department of Information Engineering, Research School of Information Sciences and Engineering, The Australian National University. ...
Sensor Platforms CNT5517 – Mobile Computing
... When conductor subject to thermal gradient, generates voltage Voltage magnitude depends on conductor material Use dissimilar conductor to complete circuit, will have different generated voltage, measure difference Voltage difference grows with temperature Very small voltages! 1-70 uV per oC! Rugged, ...
... When conductor subject to thermal gradient, generates voltage Voltage magnitude depends on conductor material Use dissimilar conductor to complete circuit, will have different generated voltage, measure difference Voltage difference grows with temperature Very small voltages! 1-70 uV per oC! Rugged, ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.