
AD9357 数据手册DataSheet 下载
... One three-input internal auxiliary ADC and two auxiliary DACs are available for system monitoring and control. A user-defined state machine can automatically sequence four GPOs. A single 3.3 V supply powers the device with on-chip low dropout linear voltage regulators (LDOs), providing all other req ...
... One three-input internal auxiliary ADC and two auxiliary DACs are available for system monitoring and control. A user-defined state machine can automatically sequence four GPOs. A single 3.3 V supply powers the device with on-chip low dropout linear voltage regulators (LDOs), providing all other req ...
6B12 数据手册DataSheet 下载
... sensor types, including: analog input, analog output, and digital I/O, the 6B Series is intended for remote data acquisition, machine monitoring, remote energy management and process monitoring and control applications. Including transformer-based isolation, ranging, linearization, A/d conversion an ...
... sensor types, including: analog input, analog output, and digital I/O, the 6B Series is intended for remote data acquisition, machine monitoring, remote energy management and process monitoring and control applications. Including transformer-based isolation, ranging, linearization, A/d conversion an ...
Power Modules Win Out, but Choose Wisely
... optimum power module to be careful in their choice of solutions. The techniques used by different power module solutions can greatly affect overall system cost, as well as key performance parameters such as heat dissipation, transient response, ripple voltage, and even ease of use. It’s very much a ...
... optimum power module to be careful in their choice of solutions. The techniques used by different power module solutions can greatly affect overall system cost, as well as key performance parameters such as heat dissipation, transient response, ripple voltage, and even ease of use. It’s very much a ...
Sector Phase Control Unit
... each of the two timing channels. Phase shifters are used to adjust the relative phases of the received signals to match each other, and to match the phase measured from the electron beam. A switch/sample-and-hold system allows the same electronics to be used for both phase comparisons, thus eliminat ...
... each of the two timing channels. Phase shifters are used to adjust the relative phases of the received signals to match each other, and to match the phase measured from the electron beam. A switch/sample-and-hold system allows the same electronics to be used for both phase comparisons, thus eliminat ...
Sample Specification PowerFlex 70 Enhanced Control GENERAL
... A software algorithm to limit the reflected wave due to long cable lengths to a maximum of 2.25 times the bus voltage or 1600V, whichever is less, up to cable lengths of 600 ft (183m). Hardware designs also limit peak voltages on the motor. ...
... A software algorithm to limit the reflected wave due to long cable lengths to a maximum of 2.25 times the bus voltage or 1600V, whichever is less, up to cable lengths of 600 ft (183m). Hardware designs also limit peak voltages on the motor. ...
homeostasis - TeacherWeb
... perpetual inner selfconstruction and selfdestruction; we destroy in order to make it new.” ...
... perpetual inner selfconstruction and selfdestruction; we destroy in order to make it new.” ...
211DS Shaking Incubator User Manual
... where the preparation or testing of materials is done at approximately atmospheric pressure and no flammable, volatile or combustible materials are being heated. This unit is not intended for hazardous or household locations or use. ...
... where the preparation or testing of materials is done at approximately atmospheric pressure and no flammable, volatile or combustible materials are being heated. This unit is not intended for hazardous or household locations or use. ...
PS22A79
... and turn-off threshold voltage. Thanks to HVIC inside the module, direct coupling to MCU without any opto-coupler or transformer isolation is possible. 10 :Fo output is open drain type. It should be pulled up to MCU or control power supply (e.g. 5V,15V) by a resistor that makes IFo up to 1mA. (IFO i ...
... and turn-off threshold voltage. Thanks to HVIC inside the module, direct coupling to MCU without any opto-coupler or transformer isolation is possible. 10 :Fo output is open drain type. It should be pulled up to MCU or control power supply (e.g. 5V,15V) by a resistor that makes IFo up to 1mA. (IFO i ...
PS22A79 < Dual-In-Line Package Intelligent Power Module >
... and turn-off threshold voltage. Thanks to HVIC inside the module, direct coupling to MCU without any opto-coupler or transformer isolation is possible. 10 :Fo output is open drain type. It should be pulled up to MCU or control power supply (e.g. 5V,15V) by a resistor that makes IFo up to 1mA. (IFO i ...
... and turn-off threshold voltage. Thanks to HVIC inside the module, direct coupling to MCU without any opto-coupler or transformer isolation is possible. 10 :Fo output is open drain type. It should be pulled up to MCU or control power supply (e.g. 5V,15V) by a resistor that makes IFo up to 1mA. (IFO i ...
the industry`s first combined rocker switch and CBE (circuit
... products for circuit protection, control and instrumentation, including the world’s largest range of circuit breakers for equipment (CBEs). E-T-A equipment is specified and installed by a wide variety of industrial OEMs and end-users, with key markets including air, sea and land transport, process c ...
... products for circuit protection, control and instrumentation, including the world’s largest range of circuit breakers for equipment (CBEs). E-T-A equipment is specified and installed by a wide variety of industrial OEMs and end-users, with key markets including air, sea and land transport, process c ...
Datasheet - Distech Controls
... 2-wire 11-1kΩ output is required use terminals P6 and P7 2-wire 0-10kΩ output is required, use terminals P5 and P6 ...
... 2-wire 11-1kΩ output is required use terminals P6 and P7 2-wire 0-10kΩ output is required, use terminals P5 and P6 ...
5 AEI 5 Automation in Instrumentation
... single and double sided boards. Surface mount devices advantages & limitations. ...
... single and double sided boards. Surface mount devices advantages & limitations. ...
Series One Programmable Controllers Series One/One Plus User`s
... 5 to 25 ms 5to25ms Logic Side 9 V dc, 130 mA (maximum) Typical, 25 mA + 4.5 mA for each ON circuit ...
... 5 to 25 ms 5to25ms Logic Side 9 V dc, 130 mA (maximum) Typical, 25 mA + 4.5 mA for each ON circuit ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.