
CONTROL SYSTEM HiCOS - HIGHVOLT Prüftechnik Dresden GmbH
... n Safety functions of the control – the control of each HIGHVOLT test system includes the safety functions Emergency-off and Safety loop, which fulfill the requirements of IEC 62061 (e.g., redundant safety loop connection). It is possible to include external emergency-off buttons and door contacts a ...
... n Safety functions of the control – the control of each HIGHVOLT test system includes the safety functions Emergency-off and Safety loop, which fulfill the requirements of IEC 62061 (e.g., redundant safety loop connection). It is possible to include external emergency-off buttons and door contacts a ...
369faq_b1 - GE Grid Solutions
... current is recommended over the G/F residual connection. This is especially true at motor starting. During across-the-line starting of large motors, care must be taken to prevent the high inrush current from operating the ground element of the 369. This is especially true when using the residual con ...
... current is recommended over the G/F residual connection. This is especially true at motor starting. During across-the-line starting of large motors, care must be taken to prevent the high inrush current from operating the ground element of the 369. This is especially true when using the residual con ...
Digital Intro
... • At high frequencies, as the open-loop gain approaches 1, the phase shift increases • If it reaches >180º degrees, and the open loop gain is >1, this results in positive feedback and high frequency oscillations • The term "phase margin" refers to the difference between the phase shift at the freque ...
... • At high frequencies, as the open-loop gain approaches 1, the phase shift increases • If it reaches >180º degrees, and the open loop gain is >1, this results in positive feedback and high frequency oscillations • The term "phase margin" refers to the difference between the phase shift at the freque ...
AD7414
... As system load increases, power dissipation increases, temperature increase, fans speeds increase, acoustics increases Closed Loop Control ensures that you are operating at the lowest possible acoustics, while providing a safe operating environment. ...
... As system load increases, power dissipation increases, temperature increase, fans speeds increase, acoustics increases Closed Loop Control ensures that you are operating at the lowest possible acoustics, while providing a safe operating environment. ...
Sucess in Vietnam Total plant solution for the Cam Pha cement plant
... The Cam Pha Cement plant is connected to the 110 kV switchyard overhead lines by means of two 25/30 MVA power transformers. The HV switchgear is air insulated (AIS) and designed for outdoor installation with increased rated voltage to compensate for the high humidity. The switchgear installation con ...
... The Cam Pha Cement plant is connected to the 110 kV switchyard overhead lines by means of two 25/30 MVA power transformers. The HV switchgear is air insulated (AIS) and designed for outdoor installation with increased rated voltage to compensate for the high humidity. The switchgear installation con ...
Chap03
... Describe the operation and use of AND gates and OR gates. Construct truth tables for AND and OR gates. Draw timing diagrams for AND and OR gates. Use timing analysis to describe the operation of an ...
... Describe the operation and use of AND gates and OR gates. Construct truth tables for AND and OR gates. Draw timing diagrams for AND and OR gates. Use timing analysis to describe the operation of an ...
Microelectromechanical Devices
... mode of operation, the regenerated power must either be dissipated in a braking resistor or fed back to the ac mains. One disadvantage of this approach is that the flux may drift due to load torque or ...
... mode of operation, the regenerated power must either be dissipated in a braking resistor or fed back to the ac mains. One disadvantage of this approach is that the flux may drift due to load torque or ...
Introduction
... The temperature sensor is used by the microcontroller to monitor the temperature within the refrigerator and based on this data control the compressor of the refrigerator. The TC72 [5] consists of a band-gap type temperature sensor, a 10-bit Sigma Delta Analog-to-Digital Converter (ADC), an internal ...
... The temperature sensor is used by the microcontroller to monitor the temperature within the refrigerator and based on this data control the compressor of the refrigerator. The TC72 [5] consists of a band-gap type temperature sensor, a 10-bit Sigma Delta Analog-to-Digital Converter (ADC), an internal ...
Redundancy in technological systems
... Besides offering this higher level of safety, the system in Figure 2 also provides significantly enhanced diagnostics. In the past, safety was often seen as a necessary evil to keep operators from making grave mistakes and getting hurt in the process. The solution in Figure 2 shows that this is not ...
... Besides offering this higher level of safety, the system in Figure 2 also provides significantly enhanced diagnostics. In the past, safety was often seen as a necessary evil to keep operators from making grave mistakes and getting hurt in the process. The solution in Figure 2 shows that this is not ...
Outdoor Cooperative Control Experiments with Quadcopters - IITB-EE
... In Table 6.1, the 1200kV , 1400kV and 1450kV motors along with all the propeller combinations are tested with 5000mAh battery. 1250_1 represents the RimFire 1250kV motor tested along with the 5000mAh battery. Similarly, 1250_2 means the same motor tested with ...
... In Table 6.1, the 1200kV , 1400kV and 1450kV motors along with all the propeller combinations are tested with 5000mAh battery. 1250_1 represents the RimFire 1250kV motor tested along with the 5000mAh battery. Similarly, 1250_2 means the same motor tested with ...
PID Voltage Control For DC Motor Using MATLAB Simulink and
... This research is to develop PID voltage control for the purpose to control the speed of a DC motor. The main contribution is the algorithm of PID controller. PID controller will be developed in MATLAB Simulink. An Arduino board is as an interfacing between MATLAB Simulink and outside world (rectifie ...
... This research is to develop PID voltage control for the purpose to control the speed of a DC motor. The main contribution is the algorithm of PID controller. PID controller will be developed in MATLAB Simulink. An Arduino board is as an interfacing between MATLAB Simulink and outside world (rectifie ...
Variable Frequency Drives 3-Phase Motor Control
... the amount of compensation allowed so that different motor types can be used. When the function is correctly tuned to the application, speed regulation tighter than 1.0% of base speed is achievable. There are some application situations which cannot use slip compensation. Multi-motor applications ca ...
... the amount of compensation allowed so that different motor types can be used. When the function is correctly tuned to the application, speed regulation tighter than 1.0% of base speed is achievable. There are some application situations which cannot use slip compensation. Multi-motor applications ca ...
PSM05S93E5-A
... 1mA. (IFO is estimated roughly by the formula of control power supply voltage divided by pull-up resistance. In the case of pulled up to 5V, 10kΩ (5kΩ or more) is recommended.) Thanks to built-in HVIC, direct coupling to MCU without any opto-coupler or transformer isolation is possible. Two VNC term ...
... 1mA. (IFO is estimated roughly by the formula of control power supply voltage divided by pull-up resistance. In the case of pulled up to 5V, 10kΩ (5kΩ or more) is recommended.) Thanks to built-in HVIC, direct coupling to MCU without any opto-coupler or transformer isolation is possible. Two VNC term ...
vsd control - ssdservice.pl
... A parallel circuit equipped with a line valve guides part of the flow back to the suction line. By opening and closing the bypass valve, the system is able to Control the delivered flow to the system. Consequently, the pump’s flow and efficiency are increased and head is reduced. Occasionally, the p ...
... A parallel circuit equipped with a line valve guides part of the flow back to the suction line. By opening and closing the bypass valve, the system is able to Control the delivered flow to the system. Consequently, the pump’s flow and efficiency are increased and head is reduced. Occasionally, the p ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.