applying fuzzy logic controller to intelligent solar panel cleaning
... a solar panel cleaning system. We applied fuzzy logic to determine the solar intensity based on the CdS circuit. Initially, under direct sunlight, the CdS value was 0.25 V, a level that indicated that the CdS has detected a light source. We then determined whether the energy conversion efficiency wa ...
... a solar panel cleaning system. We applied fuzzy logic to determine the solar intensity based on the CdS circuit. Initially, under direct sunlight, the CdS value was 0.25 V, a level that indicated that the CdS has detected a light source. We then determined whether the energy conversion efficiency wa ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
... Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Induction… response. This type of fault may result the disconnection of the semiconductor due to lifting of bonding wires caused by thermic cycling or due to a problem in the gate control signal [3]. This kind of failure ...
... Fuzzy-Logic-Controller-Based Fault Isolation in PWM VSI for Vector Controlled Induction… response. This type of fault may result the disconnection of the semiconductor due to lifting of bonding wires caused by thermic cycling or due to a problem in the gate control signal [3]. This kind of failure ...
harmonic current compensation in self excited induction generator
... instantaneous active and reactive power (p-q) strategy. When the supply voltages are balanced and sinusoidal, then all controllers converge to the same compensation characteristics. However, when the supply voltages are distorted and/or un-balanced sinusoidal, these control strategies result in diff ...
... instantaneous active and reactive power (p-q) strategy. When the supply voltages are balanced and sinusoidal, then all controllers converge to the same compensation characteristics. However, when the supply voltages are distorted and/or un-balanced sinusoidal, these control strategies result in diff ...
FST3126 4-Bit Bus Switch FST3 126 4
... Characteristics tables are not guaranteed at the absolute maximum rating. The “Recommended Operating Conditions” table will define the conditions for actual device operation. Note 2: The input and output negative voltage ratings may be exceeded if the input and output diode current ratings are obser ...
... Characteristics tables are not guaranteed at the absolute maximum rating. The “Recommended Operating Conditions” table will define the conditions for actual device operation. Note 2: The input and output negative voltage ratings may be exceeded if the input and output diode current ratings are obser ...
LM341/LM78MXX Series 3-Terminal Positive Voltage Regulators
... built-in thermal overload protection which prevents the device from being damaged due to excessive junction temperature. The regulators also contain internal short-circuit protection which limits the maximum output current, and safe-area protection for the pass transistor which reduces the short-cir ...
... built-in thermal overload protection which prevents the device from being damaged due to excessive junction temperature. The regulators also contain internal short-circuit protection which limits the maximum output current, and safe-area protection for the pass transistor which reduces the short-cir ...
4-Channel, 1 MSPS, 12-Bit ADC with Sequencer in 16-Lead TSSOP AD7924-KGD
... The conversion process and data acquisition are controlled using CS and the serial clock signal, allowing the device to easily interface with microprocessors or DSPs. The input signal is sampled on the falling edge of CS and conversion is initiated at this point. There are no pipeline delays associa ...
... The conversion process and data acquisition are controlled using CS and the serial clock signal, allowing the device to easily interface with microprocessors or DSPs. The input signal is sampled on the falling edge of CS and conversion is initiated at this point. There are no pipeline delays associa ...
Proceedings of the 15th IEEE International Symposium
... has been excited by the Band Limited White Noise (BLWN) signal up while the input voltage ui has been ...
... has been excited by the Band Limited White Noise (BLWN) signal up while the input voltage ui has been ...
PFC-180 Series FEATURES Compact 1/4 Brick Package 2.30 x 1.45
... The Unive rt e r PFC-180 P owe r Facto r Correction modules are extremely miniature and lightweight AC to DC converters that operate from wide range AC input voltages and frequencies with extremely high conversion efficiency and near unity power factor. These units produce an output of 375VDC. The w ...
... The Unive rt e r PFC-180 P owe r Facto r Correction modules are extremely miniature and lightweight AC to DC converters that operate from wide range AC input voltages and frequencies with extremely high conversion efficiency and near unity power factor. These units produce an output of 375VDC. The w ...
FMS2020-001 10W GaAs WIDEBAND SPDT SWITCH Features Product Description
... Maximum Junction Temperature (TJMAX) ...
... Maximum Junction Temperature (TJMAX) ...
3B37 数据手册DataSheet 下载
... signal. All modules feature a universal pin-out and may be readily hot-swapped under full power and interchanged without disrupting field wiring. The Analog Devices 3B Series Signal Conditioning Subsystem is designed to easily handle signal conditioning problems in measurement and control applicatio ...
... signal. All modules feature a universal pin-out and may be readily hot-swapped under full power and interchanged without disrupting field wiring. The Analog Devices 3B Series Signal Conditioning Subsystem is designed to easily handle signal conditioning problems in measurement and control applicatio ...
III. DFIG-Based Wind Turbine Control
... wind-turbine generators must remain connected to electricity networks at voltage levels well below nominal [1]. Achieving reliable operation at greatly reduced voltage levels is proving problematic. A particular problem is that standard controllers designed for reliable operation around nominal volt ...
... wind-turbine generators must remain connected to electricity networks at voltage levels well below nominal [1]. Achieving reliable operation at greatly reduced voltage levels is proving problematic. A particular problem is that standard controllers designed for reliable operation around nominal volt ...
3C Accurate, Factory Preset Thermostat
... The LM26NV can be applied easily in the same way as other integrated-circuit temperature sensors. It can be glued or cemented to a surface. The temperature that the LM26NV is sensing will be within about +0.06°C of the surface temperature to which the LM26NV's leads are attached to. This presumes th ...
... The LM26NV can be applied easily in the same way as other integrated-circuit temperature sensors. It can be glued or cemented to a surface. The temperature that the LM26NV is sensing will be within about +0.06°C of the surface temperature to which the LM26NV's leads are attached to. This presumes th ...
ABB i-bus KNX Application manual Heating/Ventilation/Air Conditioning
... The predominant application for heating, ventilation and temperature control with KNX is in the area of roomoriented temperature control or individual room temperature control. By detecting the actual temperature value and specifying a respective temperature setpoint with a control algorithm, the th ...
... The predominant application for heating, ventilation and temperature control with KNX is in the area of roomoriented temperature control or individual room temperature control. By detecting the actual temperature value and specifying a respective temperature setpoint with a control algorithm, the th ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.