
ID2 Intelligent 2 Wire Fire Detection
... cost savings on labour/product) and has the facility to ‘I.D.’ the devices. The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest, most powerful system. ...
... cost savings on labour/product) and has the facility to ‘I.D.’ the devices. The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest, most powerful system. ...
LM2576
... comparison with popular three-terminal limear reguators, especially with higher input voltages. In many cases, the power dissipated is so low that no heatsink is required or its size could be reduced dramatically. A standard series of inductors optimized for use with the LM2576 are available from se ...
... comparison with popular three-terminal limear reguators, especially with higher input voltages. In many cases, the power dissipated is so low that no heatsink is required or its size could be reduced dramatically. A standard series of inductors optimized for use with the LM2576 are available from se ...
STP 3 & 4
... from one area to another or from outside to the inside. The watertight doors are alarmed to alert security personnel that a watertight door is open but, with the exception of the watertight doors in the RSW pump house, will not alarm to indicate that a door is not dogged. To guard against a door bei ...
... from one area to another or from outside to the inside. The watertight doors are alarmed to alert security personnel that a watertight door is open but, with the exception of the watertight doors in the RSW pump house, will not alarm to indicate that a door is not dogged. To guard against a door bei ...
Control Motor ECM3000
... • Be sure to apply non-voltage wiring to terminals S, CONT, CW, and CCW of ECM3000 models with an open/close override function. In some cases M744 and M7284 control motors take 24Vac to terminals S, CONT, CW, and CCW. If one of these models is replaced with an ECM3000 with open/close override functi ...
... • Be sure to apply non-voltage wiring to terminals S, CONT, CW, and CCW of ECM3000 models with an open/close override function. In some cases M744 and M7284 control motors take 24Vac to terminals S, CONT, CW, and CCW. If one of these models is replaced with an ECM3000 with open/close override functi ...
Alberta Reliability Standard Automatic Generation Control BAL-005-AB-0.2b
... MR13.2 Evidence of not filtering metering data or area control error signals as required in requirement R13.2 exists. Evidence may include data files showing that the MW metering data for synchronous interconnections or area control error signals transmitted to the ISO are not filtered prior to tran ...
... MR13.2 Evidence of not filtering metering data or area control error signals as required in requirement R13.2 exists. Evidence may include data files showing that the MW metering data for synchronous interconnections or area control error signals transmitted to the ISO are not filtered prior to tran ...
Analog Devices Welcomes Hittite Microwave Corporation
... 1. Set A/B control to 0/+5V, Vdd = +5V and use HCT series logic to provide a TTL driver interface. 2. Control inputs A/B can be driven directly with CMOS logic (HC) with Vdd = +5 Volts applied to the CMOS logic gates. 3. DC blocking capacitors are required for each RF port as shown. Capacitor value ...
... 1. Set A/B control to 0/+5V, Vdd = +5V and use HCT series logic to provide a TTL driver interface. 2. Control inputs A/B can be driven directly with CMOS logic (HC) with Vdd = +5 Volts applied to the CMOS logic gates. 3. DC blocking capacitors are required for each RF port as shown. Capacitor value ...
STP 3 & 4
... Water (RSW) pump house. The other buildings do not contain safety-related equipment and are not connected to buildings that do. Tunnels from each of these buildings which are routed to the radwaste building are sealed to prevent interbuilding flooding. Therefore, the interbuilding flooding probabili ...
... Water (RSW) pump house. The other buildings do not contain safety-related equipment and are not connected to buildings that do. Tunnels from each of these buildings which are routed to the radwaste building are sealed to prevent interbuilding flooding. Therefore, the interbuilding flooding probabili ...
Target Datasheet
... This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operation is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. ...
... This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operation is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. ...
AMTRONIC Type Series Booklet
... Min. current rating: Max. voltage drop: Leakage current: Max. switching frequency: Operating status indication: ...
... Min. current rating: Max. voltage drop: Leakage current: Max. switching frequency: Operating status indication: ...
Transmitter Architectures
... input data is first shaped (limit it’s spectral width) by a Gaussian filter in the time domain and then applied to the FM modulator the modulator take the digital data at input, and a Gaussian filter with a bandwidth of half of the data rate will produce the desired Gaussian spectrum in the freq ...
... input data is first shaped (limit it’s spectral width) by a Gaussian filter in the time domain and then applied to the FM modulator the modulator take the digital data at input, and a Gaussian filter with a bandwidth of half of the data rate will produce the desired Gaussian spectrum in the freq ...
Isotherm Cruise (and ASU) instruction manual
... The boiled refrigerant gas is pumped out of the evaporator by the compressor allowing the boiling process to continue. The heat is carried out of the box by the gas. As the gas passes through the compressor, its pressure and temperature increase. This compressed gas then passes to the condensing uni ...
... The boiled refrigerant gas is pumped out of the evaporator by the compressor allowing the boiling process to continue. The heat is carried out of the box by the gas. As the gas passes through the compressor, its pressure and temperature increase. This compressed gas then passes to the condensing uni ...
The ME118 SN754410 Dual 1A H-Bridge Module
... Texas Instrument’s SN754410 is a quadruple half-H driver with control logic, integrated into a 16-pin DIP IC. Each driver has 1A maximum current drive capability. Two half-H drivers may be combined together to form a full H-bridge, so that it can be used for bi-directional control of motors or other ...
... Texas Instrument’s SN754410 is a quadruple half-H driver with control logic, integrated into a 16-pin DIP IC. Each driver has 1A maximum current drive capability. Two half-H drivers may be combined together to form a full H-bridge, so that it can be used for bi-directional control of motors or other ...
TJ49150 1.5A Very Low Input / Output Voltage Ultra Low Dropout
... The TJ49150 is a high performance, low dropout linear regulator, designed for high current application that requires fast transient response. The TJ49150 operates from two input supply voltages, significantly reducing dropout voltage. The TJ49150 is designed so that a minimum of external component a ...
... The TJ49150 is a high performance, low dropout linear regulator, designed for high current application that requires fast transient response. The TJ49150 operates from two input supply voltages, significantly reducing dropout voltage. The TJ49150 is designed so that a minimum of external component a ...
Page 1 of 2 Phenomenon Possible Causes Solutions
... 3. Reduce the filter inductance values or lower the internal resistance of inductor 4. Increasing conductor cross-sectional area or shorten the wire length in order to reduce the resistance, or increase the input voltage 5. Enough input end energy storage capacitor and the capacitance should get muc ...
... 3. Reduce the filter inductance values or lower the internal resistance of inductor 4. Increasing conductor cross-sectional area or shorten the wire length in order to reduce the resistance, or increase the input voltage 5. Enough input end energy storage capacitor and the capacitance should get muc ...
ADDRESSABLE INTERFACE UNITS
... the isolator (eg for a DVM cable continuity check), fit a shorting link to position J1. The ZIU is now addressed by 3 rotary switches, one for 100`s one for 10`s, one for units. Select an address between 1 & 126. (The picture shows 037) PCB Identification ...
... the isolator (eg for a DVM cable continuity check), fit a shorting link to position J1. The ZIU is now addressed by 3 rotary switches, one for 100`s one for 10`s, one for units. Select an address between 1 & 126. (The picture shows 037) PCB Identification ...
DVC10 User Guide - High Country Tek, Inc.
... +POWER IN when turned on. The PWM outputs are used to vary current to the valves (switch to ground at a high frequency). This regulated valve current provides a constant valve output, which is unchanged by coil resistance or power supply fluctuations. An indicator located on the module displays the ...
... +POWER IN when turned on. The PWM outputs are used to vary current to the valves (switch to ground at a high frequency). This regulated valve current provides a constant valve output, which is unchanged by coil resistance or power supply fluctuations. An indicator located on the module displays the ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.