
MAX890L 1.2A, Current-Limited, High-Side P-Channel Switch with Thermal Shutdown General Description
... output short-circuit conditions, it is very important to keep all traces as short as possible to reduce the effect of undesirable parasitic inductance. Place input and output capacitors as close as possible to the device (no more than 5mm). Under normal operating conditions, the package can dissipat ...
... output short-circuit conditions, it is very important to keep all traces as short as possible to reduce the effect of undesirable parasitic inductance. Place input and output capacitors as close as possible to the device (no more than 5mm). Under normal operating conditions, the package can dissipat ...
UT54ACTS220 - Aeroflex Microelectronic Solutions
... 1. Functional tests are conducted in accordance with MIL-STD-883 with the following input test conditions: VIH = VIH(min) + 20%, - 0%; VIL = VIL(max) + 0%, 50%, as specified herein, for TTL, CMOS, or Schmitt compatible inputs. Devices may be tested using any input voltage within the above specified ...
... 1. Functional tests are conducted in accordance with MIL-STD-883 with the following input test conditions: VIH = VIH(min) + 20%, - 0%; VIL = VIL(max) + 0%, 50%, as specified herein, for TTL, CMOS, or Schmitt compatible inputs. Devices may be tested using any input voltage within the above specified ...
Spec Sheet - Boston Light Source
... Matching feed canopy at support nLight-enabled control module per row/zone with 80% constant lumen management nLight-enabled control module per row/zone with NO lumen management ...
... Matching feed canopy at support nLight-enabled control module per row/zone with 80% constant lumen management nLight-enabled control module per row/zone with NO lumen management ...
MAX6576/MAX6577 SOT Temperature Sensors with Period/Frequency Output General Description
... with a period proportional to absolute temperature (°K). The MAX6577 converts the ambient temperature into a square wave with a frequency proportional to absolute temperature. The MAX6576 offers accuracy of ±3°C at +25°C, ±4.5°C at +85°C, and ±5°C at +125°C. The MAX6577 offers accuracy of ±3°C at +2 ...
... with a period proportional to absolute temperature (°K). The MAX6577 converts the ambient temperature into a square wave with a frequency proportional to absolute temperature. The MAX6576 offers accuracy of ±3°C at +25°C, ±4.5°C at +85°C, and ±5°C at +125°C. The MAX6577 offers accuracy of ±3°C at +2 ...
Design Review David Schlais – Robbie Wankewycz – Jamie Barber
... There will be a current limiter preceding each photomultiplier tube which will monitor the voltage and current that goes to each photomultiplier tube and break the circuit if the current surges above 40mA. There will be one of these for each photomultiplier tube. Each current limiter will also be ab ...
... There will be a current limiter preceding each photomultiplier tube which will monitor the voltage and current that goes to each photomultiplier tube and break the circuit if the current surges above 40mA. There will be one of these for each photomultiplier tube. Each current limiter will also be ab ...
Full Material(s)-Please Click here
... Design of such products and processes, therefore, has to be the outcome of a multi-disciplinary activity rather than ...
... Design of such products and processes, therefore, has to be the outcome of a multi-disciplinary activity rather than ...
this PDF file
... Your PC-3T Active Board has the facility to engage or bypass cathode feedback(CFB). Don't worry - it's not as complicated as it sounds. It is activated or switched off with a two pin header on each channel with shorting blocks that control this function. With the block fully engaged on the header pi ...
... Your PC-3T Active Board has the facility to engage or bypass cathode feedback(CFB). Don't worry - it's not as complicated as it sounds. It is activated or switched off with a two pin header on each channel with shorting blocks that control this function. With the block fully engaged on the header pi ...
Circuit Note CN-0150
... The RF signal being measured is applied to the AD8318. The device is configured in its so-called measurement mode, with the VSET and VOUT pins connected together. In this mode, the output voltage vs. the input signal level is linear-in-dB (nominally −24 mV/dB) and has a typical output voltage range ...
... The RF signal being measured is applied to the AD8318. The device is configured in its so-called measurement mode, with the VSET and VOUT pins connected together. In this mode, the output voltage vs. the input signal level is linear-in-dB (nominally −24 mV/dB) and has a typical output voltage range ...
APD 2000 - Absolute Process Instruments
... The APD 2000 DuoPak accepts two DC voltage or current inputs and provides two optically isolated DC voltage or current outputs that are linearly related to the inputs. The input ranges and the output ranges for each channel are independent and can be specified as required. This provides an economica ...
... The APD 2000 DuoPak accepts two DC voltage or current inputs and provides two optically isolated DC voltage or current outputs that are linearly related to the inputs. The input ranges and the output ranges for each channel are independent and can be specified as required. This provides an economica ...
SB0800 Octal Valves and Pump Controller System on Chip
... For more information, visit freescale.com/analog Freescale, the Freescale logo and QorlQ are trademarks of Freescale Semiconductor, Inc., Reg. U.S. Pat. & Tm. Off. SMARTMOS is a trademark of Freescale Semiconductor, Inc. All other product or service names are the property of their ...
... For more information, visit freescale.com/analog Freescale, the Freescale logo and QorlQ are trademarks of Freescale Semiconductor, Inc., Reg. U.S. Pat. & Tm. Off. SMARTMOS is a trademark of Freescale Semiconductor, Inc. All other product or service names are the property of their ...
Grinder Pumps
... _____ Anti-Condensation heater. A heater thermostat which protects panel components from condensing moisture by keeping the air temperature above dew point. _____ Alternator selector switch. Enables the operator to manually pre-set the lead pump or allows the control system to automatically alternat ...
... _____ Anti-Condensation heater. A heater thermostat which protects panel components from condensing moisture by keeping the air temperature above dew point. _____ Alternator selector switch. Enables the operator to manually pre-set the lead pump or allows the control system to automatically alternat ...
LTC1392 - Micropower Temperature, Power Supply and Differential
... due to self-heating effects. At sampling rates less than 400 samples per second, less than 20µA current is drawn from the supply (see Typical Performance Characteristics) and the die self-heating effect is negligible. This LTC1392 can be attached to a surface (such as microprocessor chip or a heat s ...
... due to self-heating effects. At sampling rates less than 400 samples per second, less than 20µA current is drawn from the supply (see Typical Performance Characteristics) and the die self-heating effect is negligible. This LTC1392 can be attached to a surface (such as microprocessor chip or a heat s ...
Delphi DNT04, Non-Isolated Point of Load
... Delta Electronics, Inc. The DNT04 series provides a programmable output voltage from 0.75V to 3.63V via external resistors. This product family is available in surface mount or SIP package and provides up to 3A of output current in an industry standard footprint. With creative design technology and ...
... Delta Electronics, Inc. The DNT04 series provides a programmable output voltage from 0.75V to 3.63V via external resistors. This product family is available in surface mount or SIP package and provides up to 3A of output current in an industry standard footprint. With creative design technology and ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.