AN-533: Applying 5B Series Backplanes and Mounting Cards
... One signal path is provided for inputs and one for outputs. Input and output modules are independently addressed by two sets of six address pins and an enable pin. In addition, a number of grounded pins are present in the connector pinout to provide shield conductors in the ribbon cable. In some cas ...
... One signal path is provided for inputs and one for outputs. Input and output modules are independently addressed by two sets of six address pins and an enable pin. In addition, a number of grounded pins are present in the connector pinout to provide shield conductors in the ribbon cable. In some cas ...
A mixed-signal sensor interface microinstrument
... reusing existing wires and distributes the priority arbitration logic among all peripherals. Therefore, a system with only a few peripherals will not have the entire priority arbitration logic wasting area in the core. To reduce dynamic power consumption, the MS-8 has a programmable clock manager (C ...
... reusing existing wires and distributes the priority arbitration logic among all peripherals. Therefore, a system with only a few peripherals will not have the entire priority arbitration logic wasting area in the core. To reduce dynamic power consumption, the MS-8 has a programmable clock manager (C ...
TEA6415C
... CVBS or black level for RGB signals). Each nominal gain between any input and output is 6.5dB. For D2MAC or Chroma signal the alignment is switched off by forcing, with an external resistor bridge, 5 VDC on the input. Each input can be used as a normal input or as a MAC or Chroma ...
... CVBS or black level for RGB signals). Each nominal gain between any input and output is 6.5dB. For D2MAC or Chroma signal the alignment is switched off by forcing, with an external resistor bridge, 5 VDC on the input. Each input can be used as a normal input or as a MAC or Chroma ...
PLUS+1 Compliant JS6000 PWM Service Tool
... Monitoring Proportional Inputs Click on Proportionals in the Log Functions section of the tree in the Diagnostic Navigator. When monitoring Proportional Inputs, the real-time values of the inputs will be shown. The values are shown in units of Pct*10. For example, a value of 469 is actually 46.9%. T ...
... Monitoring Proportional Inputs Click on Proportionals in the Log Functions section of the tree in the Diagnostic Navigator. When monitoring Proportional Inputs, the real-time values of the inputs will be shown. The values are shown in units of Pct*10. For example, a value of 469 is actually 46.9%. T ...
50 mA, 24 V, 3.2-uA Supply Current, Low Dropout, Linear Regulator
... microcontroller. Its ultra-low supply current maximizes efficiency at light loads, and its high input voltage range makes it suitable for supplies such as unconditioned solar panels. ...
... microcontroller. Its ultra-low supply current maximizes efficiency at light loads, and its high input voltage range makes it suitable for supplies such as unconditioned solar panels. ...
Dual Pulse-Width-Modulation Control Circuits
... Amplifier input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V Collector output voltage, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
... Amplifier input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V Collector output voltage, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
AD420 数据手册DataSheet 下载
... (CLOCK, DATA IN, LATCH) while another input is logic high, the part may be triggered into a test mode and the contents of the data register may become corrupted, which may result in the output being loaded with an incorrect value. If fast edges are expected on the digital input lines, it is recommen ...
... (CLOCK, DATA IN, LATCH) while another input is logic high, the part may be triggered into a test mode and the contents of the data register may become corrupted, which may result in the output being loaded with an incorrect value. If fast edges are expected on the digital input lines, it is recommen ...
Heat Transfer Error
... relatively high changes in resistance (a non-linear response). However, away from the maximum sensitivity point, thermistors are less able to resolve changes in temperature. Padding resistors may be added in a voltage divider circuit to obtain a more linear response. Thermistors are capable of being ...
... relatively high changes in resistance (a non-linear response). However, away from the maximum sensitivity point, thermistors are less able to resolve changes in temperature. Padding resistors may be added in a voltage divider circuit to obtain a more linear response. Thermistors are capable of being ...
AD8016 Low Power, High Output Current xDSL Line Driver Data
... (PWDN0, PWDN1) allow the driver to be capable of full performance, an output keep-alive state, or two intermediate bias states. The keep-alive state biases the output transistors enough to provide a low impedance at the amplifier outputs for back termination. The low power dissipation, high output c ...
... (PWDN0, PWDN1) allow the driver to be capable of full performance, an output keep-alive state, or two intermediate bias states. The keep-alive state biases the output transistors enough to provide a low impedance at the amplifier outputs for back termination. The low power dissipation, high output c ...
FAQ : Resistors
... The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from RO ...
... The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from RO ...
Induction Machine Speed Control
... excessive heat build up inside the speed control unit housing. They would like to increase the maximum allowed current of the speed control unit up to sixteen amperes thereby making it possible to sell their products to a wider range of customers with different needs for example control of pumps and ...
... excessive heat build up inside the speed control unit housing. They would like to increase the maximum allowed current of the speed control unit up to sixteen amperes thereby making it possible to sell their products to a wider range of customers with different needs for example control of pumps and ...
BDTIC www.BDTIC.com/infineon Industrial Power Control
... Description The 1EDI20N12AF is a galvanically isolated single channel FET driver in a PG-DSO-8-51 package that provides output currents of at least 2 A at separated output pins. The input logic pins operate on a wide input voltage range from 3 V to 15 V using CMOS threshold levels to ...
... Description The 1EDI20N12AF is a galvanically isolated single channel FET driver in a PG-DSO-8-51 package that provides output currents of at least 2 A at separated output pins. The input logic pins operate on a wide input voltage range from 3 V to 15 V using CMOS threshold levels to ...
Air Cooled Condensers
... may become loose during shipment. Tightening of wire connections is the responsibility of the installing contractor. 2.5 Phase The air cooled condenser may be ordered as three phase but the individual fan motors are single phase and will only run in one direction. Check operation by placing a moment ...
... may become loose during shipment. Tightening of wire connections is the responsibility of the installing contractor. 2.5 Phase The air cooled condenser may be ordered as three phase but the individual fan motors are single phase and will only run in one direction. Check operation by placing a moment ...
Check / Adjust / Repair Servo- and Proportional Valves
... Test stand ValveExpert equipped by programmable PWM current amplifier which can drive most of two or one coils proportional directional control valves without position feedback and with maximal current up to 3.5A (see Figure 11, Figure 12). All parameters of the electronics can be adjusted via a ser ...
... Test stand ValveExpert equipped by programmable PWM current amplifier which can drive most of two or one coils proportional directional control valves without position feedback and with maximal current up to 3.5A (see Figure 11, Figure 12). All parameters of the electronics can be adjusted via a ser ...
Media Center | SMARTEK Vision
... to search for SMARTEK Vision controllers over Ethernet and RS232, all found devices are shown in the list below. Note: There is one of three available flags in front of the Strobe Controller connection displayed in the list of found devices: Device available and waiting for connection Connection to ...
... to search for SMARTEK Vision controllers over Ethernet and RS232, all found devices are shown in the list below. Note: There is one of three available flags in front of the Strobe Controller connection displayed in the list of found devices: Device available and waiting for connection Connection to ...
ICS252 - Integrated Device Technology
... Zero Delay Buffers, or those adhering to PCI standards, the spread spectrum modulation rate should be set to 30-33 kHz. For other applications, a 120 kHz modulation option is available. ...
... Zero Delay Buffers, or those adhering to PCI standards, the spread spectrum modulation rate should be set to 30-33 kHz. For other applications, a 120 kHz modulation option is available. ...
AP2337 1.0A SINGLE CHANNEL CURRENT-LIMITED LOAD SWITCH Description
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
Control system

A control system is a device, or set of devices, that manages, commands, directs or regulates the behavior of other devices or systems. Industrial control systems are used in industrial production for controlling equipment or machines.There are two common classes of control systems, open loop control systems and closed loop control systems. In open loop control systems output is generated based on inputs. In closed loop control systems current output is taken into consideration and corrections are made based on feedback. A closed loop system is also called a feedback control system. The human body is a classic example of feedback systems.