• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ON-LINE PARAMETER ESTIMATION IN INDUCTION MOTOR
ON-LINE PARAMETER ESTIMATION IN INDUCTION MOTOR

... A hybrid electric vehicle (HEV) powertrain consists of both a mechanical power transmission path and an electric power transmission path. A supervisory vehicle controller generates the control commands for the subsystems in the powertrain based on the driver request and vehicle speed. Fuel efficienc ...
Ironless vacuum linear motor series
Ironless vacuum linear motor series

datasheet SGDH
datasheet SGDH

... Servo ON, P control (or control mode switching, zero clamp, command pulse inhibit), forward/reverse run prohibit, alarm reset, forward/reverse current limit (or internal speed switching) Servo alarm, alarm codes (3-bit output): CN1 output terminal is fixed It is possible to output three types of sig ...
Induction Motors Simulation by Finite Element Method and Different
Induction Motors Simulation by Finite Element Method and Different

... steel strip. A plurality of open slots are formed in the winding structures from the outer edge toward the rotating shaft at equal intervals, leaving part of the magnetic steel strips. Single phase induction motors are normally provided with a cage type rotor and a coiled stator having two windings, ...
PCA1462U
PCA1462U

... After a motor pulse, the motor is short-circuited to VDD for 1 ms. Afterwards the energy in the motor inductor will be dissipated to measure only the current generated by the induced motor voltage. During the time tDI (dissipation of energy time) all switches shown in Fig.5 are open to reduce the cu ...
Controlling Airflow in Class II Biosafety Cabinets
Controlling Airflow in Class II Biosafety Cabinets

How to Control and Monitor a C441 Motor Insight with
How to Control and Monitor a C441 Motor Insight with

... Control of the Freedom Contactor is accomplished via a hard-wired output on the Motor Insight’s Ethernet module. The CompactLogix PLC and its Ethernet/IP scanner port control the output via the network. This output should be wired in series with the N.C. Fault Relay contact (95/96) on the Motor Insi ...
Introduction - Sree Narayana Gurukulam College of Engineering
Introduction - Sree Narayana Gurukulam College of Engineering

... The dc machines used for industrial electric drives have three major parts. They are field system, armature and commutator. The field system is located on the stationary part of the machine called stator and consists of main poles, interpoles and frame or yoke. The main poles are designed to produce ...
AG#37EM _Imp Features of Stator Slot Insul Systems_
AG#37EM _Imp Features of Stator Slot Insul Systems_

TP2000-AP2300 Modellbasierte Entwicklung innovativer
TP2000-AP2300 Modellbasierte Entwicklung innovativer

... In this work package we focus on the possibilities to optimize the energy flow between different electric actuators, which cope with the task of driving, by the use of real-time optimization based control and estimation techniques. The aim is to find a control strategy via model based control which ...
Transient Peak Currents in Permanent Magnet Synchronous Motors
Transient Peak Currents in Permanent Magnet Synchronous Motors

Diagnostics - Mech-Line
Diagnostics - Mech-Line

... • Missing mains phase. • Blown fuse. ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... fuse, B3=blown fuses, B4=no routine maintenance, B5=due to mechanical stress, B6=prime mover is not able to move the alternator, B7=due to insulation failure, B8=due to variation of speed, B9=rotor windings are kept open, B10=two or more coils in rotor winding are shorted with each other, B 11=coils ...
SLO-SYN Bipolar Model SD200 Step Motor Drive
SLO-SYN Bipolar Model SD200 Step Motor Drive

... added EMI shielding, the printed circuit board area below where the module is mounted could be used as an effective sixth side shield. The Module has an internal capacitor connected across the motor/module supply pins (13 and 18) to assure circuit stability. This capacitor cannot handle high values ...
Technical Guide No. 102
Technical Guide No. 102

... paths along the surface of the varnished windings, especially when combined with moisture from the surrounding environment. This facilitates high frequency surface tracking, which can effectively produce short circuits between otherwise insulated portions of the windings. ...
Low voltage motors Motor guide
Low voltage motors Motor guide

... applications requiring a high power to size ratio and extend from frame size 90 to 315, or 1.1 to 350 kW, with a minimum efficiency level of IE2. As the name suggests, IE4 synchronous reluctance motors provide the highest efficiency available and range from frame size 160 to 315, corresponding to 7. ...
SEL-710 Motor Protection Relay
SEL-710 Motor Protection Relay

MN770 Evelator Application Guide
MN770 Evelator Application Guide

... In the United States, most controls sold for use in elevator applications are for modernizations. A modernization involves upgrading an existing elevator to meet present codes and performance levels. In these cases, usually only a control is sold. Existing motors are used. An encoder feedback device ...
Electrical Hazards - MEO COC Oral and Objective Exam for Marine
Electrical Hazards - MEO COC Oral and Objective Exam for Marine

The latest Soft-Starter Technology
The latest Soft-Starter Technology

... Thermal Analysis may be required to determine proper size for the following: ...
DEC Module 50/5 Operating Instructions
DEC Module 50/5 Operating Instructions

... Improper repairs can result in substantial dangers for the user ...
deg
deg

Choosing servomotor brakes
Choosing servomotor brakes

... are some important factors to consider before making a selection. ...
VII. Eddy-Current Heating by Pulse Magnet
VII. Eddy-Current Heating by Pulse Magnet

P50330 (DC) Installation Manual Edition: C - January 2014
P50330 (DC) Installation Manual Edition: C - January 2014

... indexer that provides these as a minimum (2.5 - 24 volt logic). A compatible indexer will provide the capability to drive the input circuits described in Appendix A. For most applications that operate at speeds above 300 rpm, an indexer that can ramp the step frequency is required. ...
< 1 ... 9 10 11 12 13 14 15 16 17 ... 116 >

AC motor



An AC motor is an electric motor driven by an alternating current (AC). The AC motor commonly consists of two basic parts, an outside stationary stator having coils supplied with alternating current to produce a rotating magnetic field, and an inside rotor attached to the output shaft producing a second rotating magnetic field. The rotor magnetic field may be produced by permanent magnets, reluctance saliency, or DC or AC electrical windings.Less commonly, linear AC motors operate on similar principles as rotating motors but have their stationary and moving parts arranged in a straight line configuration, producing linear motion instead of rotation.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms