• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Picture Archiving and Communication System
Picture Archiving and Communication System

...  The client fills in the query object with the keys that should be matched.  The client creates empty attributes (attributes with zero length string values) for all the attributes it wishes to receive from the server.  The query object is sent to the server.  The server sends back to the client ...
Principles of Intraoral Imaging
Principles of Intraoral Imaging

... Otto Walkhoff developed the original dental “roentgenogram” from a portion of a glass imaging plate. The image required 25 minutes of exposure time. Since their discovery, creating X-rays has not been much of a technical limitation; containing the X-rays, and limiting patient exposure to ionizing ra ...
dual energy
dual energy

... 2001 1st 16-slice 0.42 sec CT 1998 1st 4-slice 0.5 sec CT 1995 World’s smallest whole-body CT 1995 Gated multiphase cardiac imaging ...
Review of Medical Imaging Competencies for Image Interpretation
Review of Medical Imaging Competencies for Image Interpretation

... variations are covered in more detail. However, it is not evident to what depth and detail ...
Procedure Guideline for General Imaging
Procedure Guideline for General Imaging

... The Society of Nuclear Medicine (SNM) has written and approved these guidelines as an educational tool designed to promote the costeffective use of high-quality nuclear medicine procedures or in the conduct of research and to assist practitioners in providing appropriate care for patients. The guide ...
NOTES
NOTES

... A multi-slice spiral CT scanner is required for all types of CT examinations including head, spine, chest, abdomen and pelvis in addition to cardiovascular applications in a general hospital. The system must meet or transcend the minimum requirements listed below. A. Main Features 1. Type: Multislic ...
AAPM-RSNA Physics Tutorial for Residents: Typical Patient
AAPM-RSNA Physics Tutorial for Residents: Typical Patient

Test Equipment for Radiology and CT Quality Control
Test Equipment for Radiology and CT Quality Control

... For radiography two types of contrast-detail phantoms have been commonly used – the Leeds series of phantoms (www.leedstestobjects.com ) and the CDRAD phantom (www.artinis.com ). Both types of phantom contain objects of known diameter and contrast and the lowest contrast of each size which can be vi ...
A Closer Look at Pore Geometry
A Closer Look at Pore Geometry

... spaced seismic lines. Coordinates of the starting and ending points of each line are surveyed, making it possible to infer the distance between each line in the series. It is therefore possible to determine the position of any point along any line as well as the distance between points within the se ...
CT Simulation Refresher Course Sasa Mutic, MS
CT Simulation Refresher Course Sasa Mutic, MS

... therapeutic radiation doses. One shortcoming of a conventional simulation process is that very little anatomy, other than bony anatomy, is available for design of treatment portals. CT images provide information not only about target volumes but about critical (normal) organs as well. Using CT image ...
Dose Reduction and Artifacts in CT
Dose Reduction and Artifacts in CT

... Protocols stored with default parameters, but can be adjusted Be careful when adjusting! ...
ACR–SPR Practice Guideline for the Performance of Computed
ACR–SPR Practice Guideline for the Performance of Computed

... CT angiography, CT urography, CT cystography, CT colonography, CT enterography, CT cholangiography, and/or other applications deemed necessary. Such applications are best performed based on data acquired with multidetector CT. C. Some abdominal and/or pelvic CT examinations may be performed with mul ...
Digital mammography
Digital mammography

... VAT reg.no SE556064830401 ...
Lec5_Vis_In_Radiology
Lec5_Vis_In_Radiology

... • The introduction of new techniques in radiology requires careful integration in the infrastructure of radiological departments. • DICOM is essential, also for communicating results. • Analysis of conventional film-based diagnosis is inspiring. • Try to improve on the drawbacks, but also to maintai ...
View Presentation Document
View Presentation Document

... Bismuth shields are easy to use and have been shown to reduce dose to anterior organs in CT scanning . However, there are several disadvantages associated with the use of bismuth shields, especially when used with automatic exposure control or tube current modulation ...
Image-Guided Surgery
Image-Guided Surgery

... The Insight Toolkit will provide the framework and implementations for these components. The specific registration module components to be used for the proposed work involve a novel registration metric that has been previously described (Aylward, Jomier et al. 2003) and shown to provide 2.3 mm (maxi ...
Print Preview
Print Preview

... the beam. For example, the electron density information may be critical for some cases of electron beam therapy and, for high-energy photons, in regions where electronic equilibrium is not established. In such instances, methods using pixel -bypixel correction methods may be required ( 14,23). Also, ...
x-ray imaging - Teledyne DALSA
x-ray imaging - Teledyne DALSA

... performance is negligible and the output SNR is determined by X-ray quantum noise. The only way to improve the SNR of an image is to increase the dose to the patient, which is often not desirable. In other words, the quality of the detector is important if you are concerned about patient dose reduct ...
Comparison of Patient Localization Accuracy Between Stereotactic
Comparison of Patient Localization Accuracy Between Stereotactic

... before treatment. These are useful to be close to origin of the coordinate of PTV. In addition, it is possible to monitor the intra-fraction organ motion if we use them during treatment. The advantages of ETX are easier registration with bone matching, short-time patient localization, and low imagin ...
Manning, David (2005) Professor David Manning Public
Manning, David (2005) Professor David Manning Public

... imaging using observer performance data. Birkelo and his colleagues were trying to discern the diagnostic performance of traditional chest radiography compared with the (cheaper) mass miniature photo-fluorography. This was because there was urgent need of a population screening programme for pulmona ...
Required Texts for Incoming Freshman
Required Texts for Incoming Freshman

technique - Montgomery College
technique - Montgomery College

Update Course in Diagnostic Diagnostic Radiology Radiology
Update Course in Diagnostic Diagnostic Radiology Radiology

... photon-counting energy-discriminating detectors & sandwich detectors ...
Teleradiology - Canadian Association of Radiologists
Teleradiology - Canadian Association of Radiologists

... DICOM (Digital Imaging Communications in Medicine) - a standard for interconnection of medical digital imaging devices, developed by the ACR/NEMA committee. Digitize - the process by which analog (continuous wave) information is converted into digital (discrete value) information. This process is a ...
Imaging in radiotherapy - patient data acquisition.pptx
Imaging in radiotherapy - patient data acquisition.pptx

... ++ very good, + good, - poor, -- very poor ...
< 1 ... 25 26 27 28 29 30 31 32 33 ... 67 >

Fluoroscopy



Fluoroscopy /flɔrˈɒskəpi/ is an imaging technique that uses X-rays to obtain real-time moving images of the interior of an object. In its primary application of medical imaging, a fluoroscope /ˈflɔrɵˌskoʊp/ allows a physician to see the internal structure and function of a patient, so that the pumping action of the heart or the motion of swallowing, for example, can be watched. This is useful for both diagnosis and therapy and occurs in general radiology, interventional radiology, and image-guided surgery. In its simplest form, a fluoroscope consists of an X-ray source and a fluorescent screen, between which a patient is placed. However, since the 1950s most fluoroscopes have included X-ray image intensifiers and cameras as well, to improve the image's visibility and make it available on a remote display screen. For many decades fluoroscopy tended to produce live pictures that were not recorded, but since the 1960s, as technology improved, recording and playback became the norm.Fluoroscopy is similar to radiography and X-ray computed tomography (X-ray CT) in that it generates images using X-rays. The original difference was that radiography fixed still images on film whereas fluoroscopy provided live moving pictures that were not stored. However, today radiography, CT, and fluoroscopy are all digital imaging modes with image analysis software and data storage and retrieval. The use of X-rays, a form of ionizing radiation, requires the potential risks from a procedure to be carefully balanced with the benefits of the procedure to the patient. Because the patient must be exposed to a continuous source of x-rays instead of a momentary pulse, a fluoroscopy procedure generally subjects a patient to a higher absorbed dose of radiation than an ordinary (still) radiograph. Much research has been directed toward reducing radiation exposure, and recent advances in fluoroscopy technology such as digital image processing and flat panel detectors, have resulted in much lower radiation doses than former procedures.The type of fluoroscopy used in airport security (to check for hidden weapons or bombs) uses lower doses of radiation than medical fluoroscopy. It was formerly also used in retail stores in the form of shoe-fitting fluoroscopes, but such use was discontinued because it is no longer considered acceptable to use radiation exposure, however small the dose, for nonessential purposes. Only important applications such as health care, bodily safety, food safety, nondestructive testing, and scientific research meet the risk-benefit threshold for use. The reason for higher doses in medical applications is that they are more demanding about tissue contrast, and for the same reason they sometimes require contrast media.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report