• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ACR–ASTRO Practice Parameter for the Performance of Stereotactic
ACR–ASTRO Practice Parameter for the Performance of Stereotactic

... This practice parameter was revised collaboratively by the American College of Radiology (ACR) and the American Society for Radiation Oncology (ASTRO). Stereotactic body radiation therapy (SBRT) is an external beam radiation therapy method that very precisely delivers a high dose of radiation to an ...
Guidance for Compliance Testing for Phototimer (AEC) Systems The
Guidance for Compliance Testing for Phototimer (AEC) Systems The

... Testing is done a non-uniform manner throughout the regulated community. This document Addresses the routine QC testing that is to be done in the regulated community for Phototimer systems and presented to Inspectors during mandated facility inspections. The facility’s report should include all info ...
Abstract
Abstract

... Substantial further improvements can be foreseen. Efforts are underway to achieve more versatile functional labeling and radiological functional imaging in the nanometer scale. The current 30nm lateral resolution with the x-ray zone plate microscope is still far from the theoretical diffraction limi ...
A novel EPID design for enhanced contrast and detective quantum
A novel EPID design for enhanced contrast and detective quantum

... The beams-eye-view perspective of the patient’s anatomy is particularly well suited for image guided radiotherapy (IGRT). Applications include the assessment of patient setup before and during treatment delivery as well as advanced motion assessment techniques such as markerless tumor tracking (Herm ...
Time-resolved projection angiography after bolus injection of
Time-resolved projection angiography after bolus injection of

X-ray detectors for digital radiography
X-ray detectors for digital radiography

Real-time Position Management™ System
Real-time Position Management™ System

... Once it is determined how the tumor moves in relation to the waveform, gating thresholds can be set along the waveform to mark when the tumor is in the desired portion of the respiratory cycle. These thresholds determine when the automatic gating system turns the treatment beam on and off. Gating th ...
Electronic portal imaging devices: a review and
Electronic portal imaging devices: a review and

... Also, Munro (1999) presents a highly detailed review of the history and technology of electronic and non-electronic portal imagers along with a discussion of a variety of theoretical and practical considerations and issues. That study also summarizes, in tabular form, features of the two EPID techno ...
TECHNICAL SPECIFICATIONS OF MULTI SLICE SPIRAL CT
TECHNICAL SPECIFICATIONS OF MULTI SLICE SPIRAL CT

... SCANNER S.N. ...
Standardized medical terminology for cardiac computed tomography
Standardized medical terminology for cardiac computed tomography

... practice, and investigation of the field, this writing group sought to delineate a nomenclature of terms commonly used in clinical and investigative cardiac CT. The writing group focused on terms most relevant to cardiac CT. Not included within the scope of this document were more general terms rela ...
MATHEMATICAL METHODS IN MEDICAL IMAGE PROCESSING
MATHEMATICAL METHODS IN MEDICAL IMAGE PROCESSING

... few years as well [13]. Almost all images are now acquired digitally and integrated in a computerized picture archiving and communication system (PACS). In our discussion below, we will only give very brief descriptions of some of the most popular modalities. For more details, a very readable treatm ...
Digital Imaging and Communications in Medicine - Beck-Shop
Digital Imaging and Communications in Medicine - Beck-Shop

... PACS are medical systems (consisting of necessary hardware and software) designed and used to run digital medical imaging. They comprise digital image acquisition devices (modalities – such as computed tomography (CT) scanners, or ultrasound), digital image archives (where the acquired images are st ...
Clinical use of electronic portal imaging: Report of AAPM Radiation
Clinical use of electronic portal imaging: Report of AAPM Radiation

... detector efficiency. Equation 共4兲 shows that the SNR, like the contrast, decreases as the difference in attenuation between the object and the background 共⌬兲 decreases. However, unlike the contrast, the SNR is proportional to the number of x rays detected (A ␾ i T ␩ ⫽the area⫻fluence⫻transmission ⫻c ...
Philips SPECT/CT Systems
Philips SPECT/CT Systems

... •NM-driven acquisition user interface/protocols •No compromise to SPECT functions •X-ray CT and SPECT are in coplanar for cardiac imaging •Reconstruction with GPU for faster processing speed ...
Reducing Dose While Maintaining Image Quality for Cone Beam Computed... By Peter G. Kroening
Reducing Dose While Maintaining Image Quality for Cone Beam Computed... By Peter G. Kroening

... limiting the body’s ability to fight off diseases. A CT scan never delivers this much dose at one time, but the cumulative dose that a patient may receive can have long term effects [11]. With the improvements to CT scanners radiation dosage has been limited by reducing scan time. CT scanners come w ...
Full Text  - Nepal Journal of Neuroscience
Full Text - Nepal Journal of Neuroscience

- Wiley Online Library
- Wiley Online Library

... The QA procedures involve periodic measurements of specified parameters using dedicated tools that are validated with specific acceptability criteria and tolerance levels to ensure that hardware and software functions safely and reliably perform as expected. Vendors may provide instructions on how t ...
X-ray film reject rate analysis at eight selected government hospitals
X-ray film reject rate analysis at eight selected government hospitals

... rate of all the hospitals studied was 3.1%. This figure is lower (4.46%) than that obtained from an earlier study done in two hospitals in Addis Ababa in 2005 (3). Overall, the figure is well within the internationally accepted range [9-14].However, caution needs to be exercised in making comparison ...
Cone Beam CT guided Radiotherapy
Cone Beam CT guided Radiotherapy

... • Organ motion limits accuracy of radiotherapy • Cone-beam CT provides soft tissue contrast, is efficient and does not require moving or touching the patient • (4D) CBCT provides a wealth of information (and a huge amount of data!) • Dose needed for CBCT scan is considerably smaller than for standar ...
Registration of Multimodal Medical Images
Registration of Multimodal Medical Images

Low dose CT of the lumbar spine has better image quality than
Low dose CT of the lumbar spine has better image quality than

... of intra-individual and inter-individual agreement and an evaluation of whether BMI was a confounder. The protocol for low dose CT at 1 mSv level used in the current study was derived from a previous phantom study (9). The effective dose level was set as the average effective dose of lumbar spine ra ...
Tomography
Tomography

... Prize for Medicine in 1979. ...
Cochlear implantation with the BV Pulsera with - InCenter
Cochlear implantation with the BV Pulsera with - InCenter

Utah Center for Advanced Imaging Research 16th Annual UCAIR
Utah Center for Advanced Imaging Research 16th Annual UCAIR

... Purpose. Mobile C-arm fluoroscopy systems have become standard imaging devices in hospital operating rooms and surgical centers to facilitate a variety of diagnostic and interventional radiological procedures [1]. New generation of mobile (as well as higher end fixed-room) fluoroscopic systems utili ...
How Maths Can Save Your Life Chris Budd, FIMA, CMATH Bath
How Maths Can Save Your Life Chris Budd, FIMA, CMATH Bath

... We are faced with a rather unusual situation for a mathematician in that we have two perfectly plausible solutions to the same problem. Problems like this are called ill posed and are common in situations where we are trying to extract information from an image. To find out exactly how the bottles ...
< 1 ... 19 20 21 22 23 24 25 26 27 ... 67 >

Fluoroscopy



Fluoroscopy /flɔrˈɒskəpi/ is an imaging technique that uses X-rays to obtain real-time moving images of the interior of an object. In its primary application of medical imaging, a fluoroscope /ˈflɔrɵˌskoʊp/ allows a physician to see the internal structure and function of a patient, so that the pumping action of the heart or the motion of swallowing, for example, can be watched. This is useful for both diagnosis and therapy and occurs in general radiology, interventional radiology, and image-guided surgery. In its simplest form, a fluoroscope consists of an X-ray source and a fluorescent screen, between which a patient is placed. However, since the 1950s most fluoroscopes have included X-ray image intensifiers and cameras as well, to improve the image's visibility and make it available on a remote display screen. For many decades fluoroscopy tended to produce live pictures that were not recorded, but since the 1960s, as technology improved, recording and playback became the norm.Fluoroscopy is similar to radiography and X-ray computed tomography (X-ray CT) in that it generates images using X-rays. The original difference was that radiography fixed still images on film whereas fluoroscopy provided live moving pictures that were not stored. However, today radiography, CT, and fluoroscopy are all digital imaging modes with image analysis software and data storage and retrieval. The use of X-rays, a form of ionizing radiation, requires the potential risks from a procedure to be carefully balanced with the benefits of the procedure to the patient. Because the patient must be exposed to a continuous source of x-rays instead of a momentary pulse, a fluoroscopy procedure generally subjects a patient to a higher absorbed dose of radiation than an ordinary (still) radiograph. Much research has been directed toward reducing radiation exposure, and recent advances in fluoroscopy technology such as digital image processing and flat panel detectors, have resulted in much lower radiation doses than former procedures.The type of fluoroscopy used in airport security (to check for hidden weapons or bombs) uses lower doses of radiation than medical fluoroscopy. It was formerly also used in retail stores in the form of shoe-fitting fluoroscopes, but such use was discontinued because it is no longer considered acceptable to use radiation exposure, however small the dose, for nonessential purposes. Only important applications such as health care, bodily safety, food safety, nondestructive testing, and scientific research meet the risk-benefit threshold for use. The reason for higher doses in medical applications is that they are more demanding about tissue contrast, and for the same reason they sometimes require contrast media.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report