• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
S1500
S1500

... operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must b ...
HACR Ratings and UL® Listed Molded Case Circuit
HACR Ratings and UL® Listed Molded Case Circuit

Bates
Bates

...  Types of Resistance Wire  Certain applications employing heating elements (e.g., toasters) require a wire with greater resistance than common conductors.  More resistance will generate power dissipated as heat, without using excessive current.  Resistance wire is the name used to describe wires ...
Surge Protectors:
Surge Protectors:

Network design documents
Network design documents

... Allow 48 cm for the panel to swing out from the wall A distribution rack, then it must have a minimum 15.2 cm of wall clearance for the equipment, plus another 30.5-45.5 cm for physical access by workmen and repairmen ...
permitted forms of supply for portable and handheld
permitted forms of supply for portable and handheld

... at any point of utilisation permits a disconnection time not exceeding 5 seconds. Where an RCD is used, the product of rated residual current (In) and the earth fault loop impedance shall not exceed 50 (47115-06). All plugs, socket-outlets and cable couplers used in a reduced low voltage system sha ...
Surge Protective Devices TransTrack Series:
Surge Protective Devices TransTrack Series:

... materials, workmanship, or any transient surge event to include lightning, shall be repaired or replaced at the expense of the manufacturer. Prior to shipment of any suspect or known defective product a Return Material Authorization (RMA) number must be obtained. An official RMA number and shipping ...
3A1637
3A1637

... designed to be installed without additional fuses per UL 1449 3rd Edition. It is suitable for use on a circuit with maximum SCCR and Nominal Voltage according to Technical Data. This device features an internal protection system that will disconnect the surge protective module at the end of its usef ...
High Efficiency Motor Protection Industry White Paper
High Efficiency Motor Protection Industry White Paper

... These factors will cause the initial inrush current to be much higher than usual. Additionally, one other phenomenon that will exacerbate the situation is that the initial peak inrush current will not be symmetrical. ...
260553 Elec Identification
260553 Elec Identification

... signs with approved legend where instructions or explanations are needed for system or equipment operation. Install butyrate signs with metal backing for outdoor items. Emergency Operating Signs: Install engraved, laminated signs with white text on red background with minimum 3/8-inch high lettering ...
ary Friend PrEng Sales Director EXTECH SAFETY SYSTEMS PTY LTD
ary Friend PrEng Sales Director EXTECH SAFETY SYSTEMS PTY LTD

... For an explosion, all three, gas/dust, oxygen and source of ignition (spark or heat) need to be present. Intrinsic Safety works on the principle of removing the source of ignition. This can be achieved by using a Zener Barrier or Galvanic Isolator. A zener barrier is a simple device where the voltag ...
Simplified Guide to Understanding SCCR
Simplified Guide to Understanding SCCR

... • Industrial machinery electrical panels [670.3(A)] • HVAC equipment [440.4(B)] • Meter disconnect switches [230.82(3)] • Motor controllers [430.8 ] ...
Canadian Electrical Code, Part I Full Impact Assessment
Canadian Electrical Code, Part I Full Impact Assessment

... permitted voltage drop should be calculated on the demand load of the feeder or branch circuit and not on the overcurrent device feeding the feeder or branch circuit. (C) Add an Appendix B Note to Rule 8-102(3) as follows: Experience indicates that the voltage drop of lighting and general-use branch ...
Complete Technical Specifications
Complete Technical Specifications

... Panelboards are available with single-pole and two-pole, 15, 20, or 30 ampere circuit breakers. To order a panelboard with all breakers of the same rating, add the desired rating as a suffix to the Cat. No. For example, the 12 circuit D2PB1512 panelboard with all the circuit breakers rated at 20 amp ...
P85350
P85350

... 4. When terminating field wires, do not use more lead length than required. Excess lead length could result in insufficient wiring space for the signaling appliance. 5. Conduit entrances to the backbox should be selected to provide sufficient wiring clearance for the installed product. 6. Do not ...
Magnetic Speed Switch Instructions
Magnetic Speed Switch Instructions

... 1. Read and understand all wiring, selection, and mounting instructions prior to installation. If necessary, contact a PPI Applications Engineer. 2. Disconnect and lockout power before starting wiring procedure. Do not apply a voltage across the wires until a load such as a relay circuit has been ...
File
File

... The metal which makes up a light bulb filament or stovetop eye has a high electrical resistance. This causes light and heat to be given off. ...
Deerfield High School / Homepage
Deerfield High School / Homepage

... The metal which makes up a light bulb filament or stovetop eye has a high electrical resistance. This causes light and heat to be given off. ...
Electricity and Magnetism
Electricity and Magnetism

... The metal which makes up a light bulb filament or stovetop eye has a high electrical resistance. This causes light and heat to be given off. ...
Electricity and Magnetism - Warren County Public Schools
Electricity and Magnetism - Warren County Public Schools

... The metal which makes up a light bulb filament or stovetop eye has a high electrical resistance. This causes light and heat to be given off. ...
Electricity and Magnetism
Electricity and Magnetism

... The metal which makes up a light bulb filament or stovetop eye has a high electrical resistance. This causes light and heat to be given off. ...
FS-TRI-S - Fire Alarm Resources
FS-TRI-S - Fire Alarm Resources

... All power limited wiring must enter the electrical box separately from the electric light, power, Class 1, or non-powered limited fire protection signaling conductors. For the FS-TRI-R, wiring to terminal block positions 1, 2, 3, 4, and 5 must enter the outlet box separately from terminals 6, 7, and ...
Installation AC Power Distribution Panels
Installation AC Power Distribution Panels

... Practices of the American Boat and Yacht Council as well as United States Coast Guard 33 CFR Sub Part 1. ...
Bonding and Installation Requirements for CSST Gas Piping Systems.
Bonding and Installation Requirements for CSST Gas Piping Systems.

... – Reduce differences in electrical potential – Minimize the possibility of arcing • Maintain physical separation where practical • Bonding together of all metallic systems • All CSST products require the same type of bonding in accordance with current edition of NFPA 54 or IFGC or UPC ...
electrical shock - SIPE Online Training
electrical shock - SIPE Online Training

... Do not use conductive fish tape in raceways entering enclosures with exposed energized parts unless the parts are isolated by barriers. At least 3 feet of cleared space (no storage) shall be available in the direction of access to control panels, circuit breakers, switchboards, fused switches, and s ...
< 1 ... 61 62 63 64 65 66 67 68 69 ... 91 >

National Electrical Code

The National Electrical Code (NEC), or NFPA 70, is a regionally adoptable standard for the safe installation of electrical wiring and equipment in the United States. It is part of the National Fire Codes series published by the National Fire Protection Association (NFPA), a private trade association. Despite the use of the term ""national"", it is not a federal law. It is typically adopted by states and municipalities in an effort to standardize their enforcement of safe electrical practices. In some cases, the NEC is amended, altered and may even be rejected in lieu of regional regulations as voted on by local governing bodies.The ""authority having jurisdiction"" inspects for compliance with these minimum standards.