• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
proper selection of control circuit transformers
proper selection of control circuit transformers

... secondary voltage occurs with 100% of the rated line voltage applied. Combining these two conditions result in a secondary voltage of approximately 102 volts which meets the contactor pick-up requirement. ...
Identification of Impending Interturn Faults in Random
Identification of Impending Interturn Faults in Random

... 44 turns and iii) distributed parameters for the last three turns. This is based on the findings that the initial voltage distribution due to fast fronted surges in the line end coil is mostly decided by the first few turns [10, 11]. The line-end coil model has incorporated the effect of both the tr ...
Reed relays - Go ELECTRONICS
Reed relays - Go ELECTRONICS

... which can be completely separate from the first. For example a low voltage battery circuit can use a relay to switch a 230V AC mains circuit. There is no electrical connection inside the relay between the two circuits, the link is magnetic and mechanical. The coil of a relay passes a relatively larg ...
electrical systems on meriden triumphs
electrical systems on meriden triumphs

... weak spark with a Boyer and 2 x 12v coils. Some people prefer a single 12v coil with dual high-tension outputs. Boyers fire both cylinders at once, at both the top of the compression stroke (when it should happen), and at the top of the exhaust stroke (when it’s not required, but doesn’t hurt). Thi ...
High voltage pulse generators and spark gap for gaseous discharge
High voltage pulse generators and spark gap for gaseous discharge

... increase. Typical lifetime of the sparking points is generally one mil!ion shots. Cleaning frequency depends on operation, but in any case, after long periods of disuse, the electrodes should be removed and cleaned before the spark gap is brought back to firing voltage. The breakdown voltage (with n ...
Instrument Transformer Basic Technical
Instrument Transformer Basic Technical

... Current transformers are constructed in various ways. One method is quite similar to that of the potential transformer in that there are two separate windings on a magnetic steel core. But it differs in that the primary winding consists of a few turns of heavy wire capable of carrying the full load ...
Model Wave Energy Generator 2.4.3
Model Wave Energy Generator 2.4.3

... The following discussion is focused on the moving magnet design of Figure T-2. Other designs follow similar construction techniques. Winding the Coils Initially, wind the coils on the 16mm test tube. This size will accept all magnets up to 3/8 inch in diameter. The length of the winding should be a ...
Current Sensor in Solid-State Meters: How digital
Current Sensor in Solid-State Meters: How digital

... Figure 2. Phase shift caused by the self-inductance of a shunt (2nH in a 200µΩ shunt) The percentage measurement error caused by any phase mismatch between the voltage and current signal paths can be approximated by the following formula: Measurement error≈Phase mismatch ( in radian ) × tan(φ)× 10 ...
2nd Year 1st Term Lecture Material_01
2nd Year 1st Term Lecture Material_01

...  The resonant frequency of tuned circuit L1C1 is made equal to the signal frequency.  The output from this tuned circuit is transferred to the second tuned circuit L2C2 through mutual induction.  Double tuned circuits are used for coupling the various circuits of radio and television receivers. D ...
Operating Instructions for Cenco Ring Launcher
Operating Instructions for Cenco Ring Launcher

... Any damaged components should be replaced immediately. Always check components for damage before operation, particularly the power cord. The launcher should always be used under adult supervision. The current draw of this launcher can temporarily reduce the local supply voltage for other devices on ...
Instructions for use and maintenance
Instructions for use and maintenance

... FEL! BOKMÄRKET ÄR INTE DEFINIERAT. ...
As we discussed earlier capacitors and coils resist the flow
As we discussed earlier capacitors and coils resist the flow

... reactance of –j300 and an inductive reactance of +j400. When combined they would equal +j100. Lets say our circuit has 150 ohms of resistance. Placing these values in the formula we would have an impedance of 180.28 ohms. Lets presume our voltage source is 180 volts. We can easily see that the curre ...
performance coil info - Telematica Electronics
performance coil info - Telematica Electronics

... Coils have always had to compromise voltage output against current output. More voltage increases the initial ionization of the spark plug gap, but lowers the amount of current, or heat, that follows across the plug gap. When a coil is designed to produce more current, the voltage output generally s ...
armature winding
armature winding

... starting at an point, the winding is followed through all its turn and the starting point is reached again. The armature current divides itself into parallel paths. ...
Determining Transformer Phase Angle Displacment
Determining Transformer Phase Angle Displacment

... • The advantages of building a single three phase transformer is that for the same kVA rating it will be smaller, cheaper and lighter than three individual single phase transformers connected together because the copper and iron core are used more effectively. As well as having fewer bushings. The m ...
Embedded Magnetorquer Coil Design for Micro
Embedded Magnetorquer Coil Design for Micro

... combinations of coils. The value of J for microsatellite is 6.23 kg m2. The torque generated by 4 coils in parallel is 944.6 μNm, which takes 204 s to rotate satellite through an angle of 90◦. In the case of 1 and 4 coils connected in series, generated torque is 354.2 μNm, which takes 333.1 s to rot ...
tesla 3000 power system recorder
tesla 3000 power system recorder

... module is available in two models with nominal current 5 Arms (Model 401014) and 1 Arms (model 401020) with a 20x over-range capability, for 1 second. The module has input and output terminal pairs for I1 through I4. ...
Resonant Coupling Analysis for a Two-Coil Wireless
Resonant Coupling Analysis for a Two-Coil Wireless

... The idea of not being tethered to a power source by wires opens up exciting prospects. Wirelessly transferring power is critical to some applications like transcutaneous biomedical implants where it helps increase operational lifespan of such implants. In recent years, wireless power is garnering at ...
AT140A/AT150A Installation Instructions
AT140A/AT150A Installation Instructions

... faces you. 3. With the keyhole slots up, fit the mounting plate over the primary leadwires and end bell. Insert small tab at the bottom of the plate into the slot in the transformer mounting foot. 4. Insert the mounting screw (supplied) through the holes as shown in Fig. 5. Secure the plate to the t ...
ICTD-100CP / ICTD-101CP ICTD-102CP / ICTD
ICTD-100CP / ICTD-101CP ICTD-102CP / ICTD

... Unfortunately, auxiliary contacts in most breakers are only AC rated, and traditional CTDs only provide DC current. As a result, auxiliary contacts are commonly damaged, and this damage often extends to the breaker’s trip circuit. Contact Protect TechnologyTM eliminates this problem by converting th ...
PFC/JA-90-42 Innovative Design Option for Internal Coils* L.  Bromberg
PFC/JA-90-42 Innovative Design Option for Internal Coils* L. Bromberg

... mechanical and/or electrical breaks used to sever the coils. Once in sections, the parts can be removed. A problem with' ...
transformers - Crompton Instruments
transformers - Crompton Instruments

... The composition of a transformer core depends on such factors as voltage, current, and frequency. Size limitations and construction costs are also factors to be considered. Commonly used core materials are air, soft iron, and steel. Each of these materials is suitable for particular applications and ...
Installation Instructions
Installation Instructions

... maximum rating of such a filter is 40 microns to provide adequate protection. 2. Pipe thread sealing compounds and tape must be prevented from entering the valve. 3. New systems must be adequately flushed to remove all pipe scale, weld slag, thread burrs, etc. It is typically necessary to flush new ...
ABSTRACT transmission line aspects of windings yields attenuation and
ABSTRACT transmission line aspects of windings yields attenuation and

... There are two very critical differences that distinguish online PD tests from off-line tests. In the on-line situation 1. most of the coils are not operating at full voltage. This greatly reduces the PD activity in most coils. 2. the stator winding PD is superimposed on the electrical interference t ...
Rapid Wireless Capacitor Charging Using a Multi
Rapid Wireless Capacitor Charging Using a Multi

... inductance , and magnetizing inductance , as shown in Fig. 4(a). It is also well-known that circuit elements can be reflected across the terminals of an ideal transformer via a multiplicative factor of . This is the basis for reflected load analysis. Similar analysis of the circuit in Fig. 2 can be ...
< 1 ... 9 10 11 12 13 14 15 16 17 ... 43 >

Tesla coil



A Tesla coil is an electrical resonant transformer circuit invented by Nikola Tesla around 1891. It is used to produce high-voltage, low-current, high frequency alternating-current electricity. Tesla experimented with a number of different configurations consisting of two, or sometimes three, coupled resonant electric circuits.Tesla used these coils to conduct innovative experiments in electrical lighting, phosphorescence, X-ray generation, high frequency alternating current phenomena, electrotherapy, and the transmission of electrical energy without wires. Tesla coil circuits were used commercially in sparkgap radio transmitters for wireless telegraphy until the 1920s, and in medical equipment such as electrotherapy and violet ray devices. Today their main use is for entertainment and educational displays, although small coils are still used today as leak detectors for high vacuum systems.