• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Electrical Systems Existing Conditions and Building Load Summary
Electrical Systems Existing Conditions and Building Load Summary

... electrical system. The primary system is identified by two supply paths leading from the primary distribution switchgear. This type of system has the ability to provide a constant path of power (thus constant power supply) in an event when one feeder is out of service electrical power because of the ...
Vorlage für Nomos (deutsch) v1.0
Vorlage für Nomos (deutsch) v1.0

... along the line than by the thermal power rating of the conductor. That is why in practice installations for the compensation are used every 600 kilometres /Rudervall et al. 2000/. Losses of Overhead Line In addition to current-dependent losses there are also voltage-dependent losses in the form of g ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

... be needed to avoid reverse currents, in case of partial or total shading, and at night. The p-n junctions of monocrystalline silicon cells may have adequate reverse current characteristics that these are not necessary. Reverse currents waste power and can also lead to overheating of shaded cells. So ...
A 1cm3 Sensor Node Powered by Harvested
A 1cm3 Sensor Node Powered by Harvested

... Acoustic Resonator (FBAR) technology for RF carrier generation [11]. An FBAR is a MEMs device that behaves like a capacitor except at resonance, where it has Q > 1000. The FBAR is a separate die, wire bonded to the transmitter. Baseband data is modulated onto the carrier using OOK by power cycling t ...
New Title - LydRommet
New Title - LydRommet

Tensor Analysis Application to Characterize the Motor of
Tensor Analysis Application to Characterize the Motor of

... development in electric motor technology, human civilization experiences a major development. Asynchronous motors which are the integral part of asynchronous machines are the most widely used electric equipment. Electric motors introduce several advantages such as simple in terms of the physical for ...
- Jntu World
- Jntu World

... Downloaded From JNTU World ...
iD8783 - iDESYN
iD8783 - iDESYN

... AD ...
New SOT Package Supervisors
New SOT Package Supervisors

... Push-pull RESET Open-drain RESET ...
Introduction to Class
Introduction to Class

... We need to make measurements more accurately There are better test techniques and test equipment that can help us that don’t cost a fortune Think of better more stable power supplies as a free performance boost for digital and RF systems! ...
Project 2007-09 - Generator Verification
Project 2007-09 - Generator Verification

... 2.1. Verify Real Power capability and Reactive Power capability over-excited (lagging) of all applicable Facilities at the applicable Facilities’ normal (not emergency) expected maximum Real Power output at the time of the verifications. 2.1.1 Verify synchronous generating unit’s maximum real power ...
Solid State Relais
Solid State Relais

... series with the 22K resistor increases to a certain set point that it will block the BC547B transistor. The collector current at that moment will follow that of the AC voltage to a certain value which will activate the Thyristor. This creates a sufficient large voltage drop over the 330 ohm resisto ...
Printable PDF File Format
Printable PDF File Format



Large Scale Solar PV Investment Potential in Ontario 2010-2025
Large Scale Solar PV Investment Potential in Ontario 2010-2025

... – There is more control flexibility (e.g. PWM, more reactive support at the limits). – Costs are higher due to the cost of switching devices, i.e. installation costs: • MSC  10 USD/kvar • SVC  50-60 USD/kvar (100 Mvar) 35-40 USD/kvar (200 Mvar) • STATCOM  1.2-1.3 SVC ...
Timers Two-state Relay Type SG 125
Timers Two-state Relay Type SG 125

... • Switches, with a preset delay, to opposite contact position at power supply interruption • Repeatability deviation: ≤ 1% • Output: 8 A SPDT relay • Plug-in type module • S-housing • LED-indication for relay on • AC or DC power supply ...
NJM723
NJM723

... error amplefier, power-series pass transistor and current-limit circuitry. Additional NPN or PNP pass elements may be used when output currents exceeding 150mA are required. In addition to the above, the device features low standby current drain, low temperature drift and high ripple rejection. The ...
return loss
return loss

PA280003EN
PA280003EN

... countries. You are not permitted to use the Eaton Trademarks without the prior written consent of Eaton. ...
Dec 2001 Reduce Power Consumption of DSL Modems with the LT1969 Line Driver
Dec 2001 Reduce Power Consumption of DSL Modems with the LT1969 Line Driver

... to be developed across the 12.4Ω backtermination resistors. This is the line-terminate mode of operation, in which the line drivers consume only 36mW of power from a single 12V power supply. During “Show Time,” when the modem is communicating with the central office, the line driver needs more biasi ...
Generator and Transformer
Generator and Transformer

Loop and Nodal Analysis and Op Amps
Loop and Nodal Analysis and Op Amps

... For ideal transformers assume that coupling coefficient is 1. If this is the case, then both coils have the same flux. Assume the polarities of the voltages and currents result in flux going in the same direction. Then the result is: ...
Display: AC voltage AC Amperage AC frequency Max Allowed AC
Display: AC voltage AC Amperage AC frequency Max Allowed AC

... To maximize measurement resolution, the voltage across the burden resistor at peak-current should be equal to onehalf of the Arduino analog reference voltage. (AREF / 2) Arduino running at 5V: AREF / 2 will be 2.5 Volts. So the ideal burden resistance will be: Ideal burden resistance = (AREF/2) / Se ...
To Examine the Properties of a Diode
To Examine the Properties of a Diode

Document
Document

... Department of Electrical and Computer Engineering • EE20A - Electromechanical Energy Conversion • SYNCRONOUS MACHINES ...
< 1 ... 889 890 891 892 893 894 895 896 897 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report