• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CIRCUIT IDEAS FOR DESIGNERS This current source can be built
CIRCUIT IDEAS FOR DESIGNERS This current source can be built

... This current source can be built within a single IC package. The high input gate impedance of Q1 and Q2 eliminates any gate leakage current considerations in most cases, resulting in equal gate voltages of Q1 and Q2. Substantially all of the ISET current becomes the drain current of Q1. Drain curren ...
amp clamp - Advanced Media Technologies
amp clamp - Advanced Media Technologies

... Alpha’s Amp Clamp eliminates surge voltages in coaxial cable systems caused by lightning strikes, sheath currents and utility-induced switching transients. The proprietary Alpha design also resists false triggering, which is common among triac circuits. The plug-in Amp Clamp circuitry can be factory ...
INTEGRATED STARTER MOTOR GENERATORS
INTEGRATED STARTER MOTOR GENERATORS

How to use a Digital Multimeter
How to use a Digital Multimeter

... •Voltage is broke up into 2 sections AC & DC Alternating Current (AC) is house voltage (110vac) Direct Current (DC) is battery voltage (12vdc) •On switched meters use one value higher than your expected value •Be very careful to not touch any other electronic components within the equipment and do n ...
Crompton Instruments Integra Ci3 Digital Metering System
Crompton Instruments Integra Ci3 Digital Metering System

... The Integra Ci3 digital metering system (dms) represents the first model of a new generation of digital metering systems designed to complement the current Crompton Instruments Integra series. The Integra Ci3 meter is an accurate and cost effective solution for measurement and display of all major e ...
Shading Effects on Output Power of Grid Connected Photovoltaic
Shading Effects on Output Power of Grid Connected Photovoltaic

... mesure de la puissance maximale en combinaison avec le convertisseur solaire. Keywords: Power supply – Photovoltaic generators – Shading effects – Solar irradiance. ...
600 Watt SMB Transient Voltage Suppressor, 12 V, Bidirectional
600 Watt SMB Transient Voltage Suppressor, 12 V, Bidirectional

... are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor doe ...
EBPLED UL Recognized instruction sheet
EBPLED UL Recognized instruction sheet

... 3. Do not mount near gas or electric heaters 4. Equipment should be mounted in locations and at adequate heights to prevent tampering by unauthorized personnel. 5. The use of accessory equipment not recommended by Eaton may cause an unsafe condition and will void the warranty. 6. Do not use this equ ...
6 Port Gigabit Industrial PoE+ Ethernet switch with 2 SFP ports
6 Port Gigabit Industrial PoE+ Ethernet switch with 2 SFP ports

... The ESWGP206-2SFP-T is an Industrial PoE+ Ethernet switch that complies with IEEE 802.3at standards. It provides four PoE+ 10/100/1000Mbps copper ports supplying up to 30W of power to PD devices such as CCTV and WI-FI. Two 1000Mbps SFP ports are available to support gigabit fiber. The ESWGP206-2SFP- ...
RPI-5100
RPI-5100

T.W. Barton, J.L. Dawson, and D.J. Perreault, “Experimental Validation of a Four-Way Outphasing Combiner for Microwave Power Amplification,” IEEE Microwave and Wireless Component Letters , Vol. 23, No. 1, pp. 28-30, Jan. 2013.
T.W. Barton, J.L. Dawson, and D.J. Perreault, “Experimental Validation of a Four-Way Outphasing Combiner for Microwave Power Amplification,” IEEE Microwave and Wireless Component Letters , Vol. 23, No. 1, pp. 28-30, Jan. 2013.

GR-390 GR-392
GR-390 GR-392

... This is done by placing the supporting base to the cable s exit and rotating it 90 degrees. For wall mounted installation slide the supporting base on the side of the luminaire and pass the cable along the periphery as shown below . ...
Alternative DC storage Examples
Alternative DC storage Examples

... Vendor should have UPS interface experience ...
G3540
G3540

... circuit is capable of bidirectional power flow. The doubly-fed machine can be operated in generating mode in both sub-synchronous and supersynchronous modes[8].The rotor will observe slip power from the in sub-synchronous operation and can feed slip power back to grid in supersynchronous operation. ...
Исследование Влияния Параметрических Расстроек На
Исследование Влияния Параметрических Расстроек На

... In this case, the load is an electric drive up to 600 kW. This reduces the cost of additional equipment (passive and active filters, reactive power compensators), designed to reduce the reaction of the rectifier on the supply grid. The second area of application of these high-voltage rectifying sche ...
Diagnostic News On-Line Monitoring of Partial Discharge in Voltage Source January 2015
Diagnostic News On-Line Monitoring of Partial Discharge in Voltage Source January 2015

... outage and disassembly has been the direct  measurement of vibration using fiber optic  accelerometers mounted at critical locations  of the endwinding. Online monitoring can also  ...
STN9360
STN9360

... power transistor. It is manufactured using high voltage multi epitaxial planar technology for high switching speeds and medium voltage capability. It uses a cellular emitter structure with planar edge termination to enhance switching speeds while maintaining a wide RBSOA. The device is designed for ...
A New Pulse Duty Cycle Control Method with Pulse Frequency
A New Pulse Duty Cycle Control Method with Pulse Frequency

... Mode-2 of circuit operation starts when switch ‘S’ is turned off after conducting for some time. The primary winding current path is broken and according to laws of magnetic induction, the voltage polarities across the windings reverse. Reversal of voltage polarities makes the diode in the secondary ...
a voltage-controlled dstatcom for power-quality
a voltage-controlled dstatcom for power-quality

... This paper proposes a new algorithm to generate reference voltage for a distribution static compensator (DSTATCOM) operating in voltage-control mode. The proposed scheme exhibits several advantages compared to traditional voltagecontrolled DSTATCOM where the reference voltage is arbitrarily taken as ...
Small Hydropower Plant with variable speed PM generator
Small Hydropower Plant with variable speed PM generator

... During changes of working conditions the energy conversion system with the diode rectifier operates similarly to the system with PWM rectifier. Figure 12 presents chosen waveforms in the energy conversion system with the diode rectifier and the DC-DC boost converter when the guide vanes angle α is ...
Analog to Floating Point Output
Analog to Floating Point Output

SERIES 200 POWER CONDITIONERS
SERIES 200 POWER CONDITIONERS

SERIES 200 POWER CONDITIONERS
SERIES 200 POWER CONDITIONERS

UCI Power Electronics Lab
UCI Power Electronics Lab

... uninsulated VRM ...
Devtech Lighting Control Gear.cdr
Devtech Lighting Control Gear.cdr

< 1 ... 828 829 830 831 832 833 834 835 836 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report