• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Tech Note 10 Microphone Amplifier Design, or, Why
Tech Note 10 Microphone Amplifier Design, or, Why

... output of the capsule and its charging circuit, and reduce the impedance enough so that practical cables may be used between the mic and the next audio stages. The problem is that microphones are mostly operated on internationally-standardized phantom power, which sets some hard limits on the amount ...
DO PHYSICS ONLINE MOTORS AND GENERATORS
DO PHYSICS ONLINE MOTORS AND GENERATORS

... Motors and generators are structurally the same:  A generator has a mechanical input and voltage output  A motor has a voltage input and mechanical output ac generator –slip ring commutator dc generator – split ring commutator Advantages and disadvantages of ac and DC generators  AC easier to tr ...
Three Phase Semi Converter
Three Phase Semi Converter

... THREE-PHASE SEMI CONVERTER AIM: To study the waveforms for three phase semiconverter with RLE load. ...
NET-11-11-11 PRIME LED NCF Luminaire 80W
NET-11-11-11 PRIME LED NCF Luminaire 80W

... the number of manufacturers growing monthly. Our aim is to be a supplier that you can trust, with credibility and a track record of providing quality, innovative products at competitive prices. NET LED was established in 2009 and partners with manufacturers based in the UK and around the world to di ...
1500 Watt SMC Transient Voltage Suppressor, 10 V Unidir
1500 Watt SMC Transient Voltage Suppressor, 10 V Unidir

... SURMETIC is a registered trademark of Semiconductor Components Industries, LLC (SCILLC). ON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warra ...
Evaluate:  MAX9987/MAX9988 MAX9987/MAX9988 Evaluation Kits General Description Features
Evaluate: MAX9987/MAX9988 MAX9987/MAX9988 Evaluation Kits General Description Features

... the basic functionality of the EV kits. As a general precaution to prevent damaging the outputs by driving high-VSWR loads, do not turn on DC power or RF signal generators until all connections are made. 1) Calibrate the power meter at 900MHz for the MAX9987, or at 1800MHz for the MAX9988. Important ...
Power Transformers 10 to 100 MVA
Power Transformers 10 to 100 MVA

... of power. Consequently Siemens will be found wherever networks are being expanded, updated or established for the first time. All over the world, power transformers ...
User's Model 701921
User's Model 701921

... When the capacity of dry cells goes down LED blinks. In such a case, replace the dry cells. Also, do not install the dry cells when using an external power supply. This equipment is for measurement category III (CAT III). Do not use it with measurement category IV (CAT IV). CAT III applies to measur ...
Tripp Lite SMART3000CRMXL SmartPro 3kVA 2880W
Tripp Lite SMART3000CRMXL SmartPro 3kVA 2880W

... Line interactive Automatic Voltage Regulation (AVR) provides two levels of voltage boost during brownouts and one level of voltage cut during overvoltage conditions to maintain regulated 120V nominal output over an input range of 83-145V Includes NEMA L5-30P input plug (hardwire line cord installati ...
parameters which affect real and reactive power flow
parameters which affect real and reactive power flow

... P2 from the results in Table 4. Note that the addition of static capacitors has yielded a much more constant voltage, and further more, the power P2 which can be delivered has increased. On this curve, indicate the phase angle between E2 and E1 as well as the reactive power Q2 used for individual re ...
EM35787792
EM35787792

... DC-DC conversion technology is a major subject area in the field of power electronic and power engineering and drives. This conversion technique is widely adopted in industrial application and computer hardware circuits. The simplest DC-DC conversion technology is a voltage divider, potentiometer an ...
SPS2 Circuit Breaker (15kV-245kV)
SPS2 Circuit Breaker (15kV-245kV)

Turnigy RotoMax 150cc datasheet
Turnigy RotoMax 150cc datasheet

... got just as warm as the motoring one unloaded. This indicates the rotor iron sees an alternating magnetic field as the magnetic path changes as the magnets pass each pole. In the test set up the DC voltage controls speed so there is no additional PWM switching and hence loss. The motor features slot ...
Science 297
Science 297

... and 4 in the figure. This can be done using a current source or a power supply as shown. Many power supplies have a current output readout built into them. If not, an ammeter in series with this circuit can be used to obtain the value of the current. A 5 Watt power supply capable of producing up to ...
Figure 1 - Typical electronic package
Figure 1 - Typical electronic package

... Electric currents flowing from the power supply input to the voltage source are called conducted emissions (see Figure 1). Conducted emissions are generated at the input (AC or DC) by a current flow in a wire or trace in two ways: differential mode noise and common mode noise (Figure 2). Differentia ...
The desired DC voltage increase from 420 to 600 V is shown in
The desired DC voltage increase from 420 to 600 V is shown in

... 1. The voltage oscillations under ferroresonance on a cable-fed transformer can represent a severe power quality issue which can produce damage to LV DC motors if this condition is not properly detected and action taken to disconnect the DC drive from the power supply. Similar voltage fluctuations o ...
S P E C I A L   F... E L E C T R I C A L ... Input
S P E C I A L F... E L E C T R I C A L ... Input

... The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices ...
HVSBstatus_02_09 - Indico
HVSBstatus_02_09 - Indico

... There is one open question concerning of the power supplies DC decoupling. There are two possibility. First one is connect the ground lines of the MV power supplies together or other one is use an opto-coupling technique for keeping the ground lines separated. In the first case an analog part of the ...
QC2326552659
QC2326552659

... the input current compared to the continuous current mode (CCM). However, the CCM operation yields s lightly higher efficiency compared to the DCM operation. Generally, single-stage PFC converters meet the regulatory requirements regarding the input current harmonics, but they do not improve the pow ...
LR3421092114
LR3421092114

... technique is the requirement of cumbersome computation time. With the increase in highest harmonic to be eliminated, number of calculations also increase, which results in a large response time. Therefore, compensation in on-line applications has been limited in references to harmonics at or below t ...
PE3426652670
PE3426652670

... (Associate professor) EEE Department, Aurora‟s Research & Technological Institute, JNT University, Hyderabad Andhra Pradesh, India (Associate professor) EEE Department Aurora‟s Research & Technological Institute JNT University, Hyderabad Andhra Pradesh, India ...
Variable Frequency Drive (VFD) - Energy Management Corporation
Variable Frequency Drive (VFD) - Energy Management Corporation

... Note: In order to perform a complete annual test, the drive system must be available for power down and test mode operation. In the event that operations or safety issues prevent this, certain tests may be omitted. In the event of drive failure, EMC maintains a large stock of parts and assemblies as ...
Power and automation products and services Global product
Power and automation products and services Global product

... Active internal arc protection for switchgear. Innovative arc flash mitigation in less than 4 ms: the highest possible level of arc flash protection for personnel and equipment, maintenance of secure power supply and the reduction of production stoppages. The occurrence of an arc fault, the most ser ...
2016-09-27-6-generator
2016-09-27-6-generator

Earth Leakage Problem of Superconductor Magnet System at TLS
Earth Leakage Problem of Superconductor Magnet System at TLS

... For case B, the earth leakage current is caused by nonisolated analogue single-ended command input and current readback to/from the power supplies. As seen from the figure 3, the analogue command inputs to the two trim power supplies come from a DAC board, while the current readback are fed into the ...
< 1 ... 783 784 785 786 787 788 789 790 791 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report