• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Two threshold control unit for current or voltage input
Two threshold control unit for current or voltage input

Dynamo
Dynamo

... electricity. For example, in the 1870s Siemens used electromagnetic dynamos to power electric arc furnaces for the production of metals and other materials. The dynamo machine that was developed consisted of a stationary structure, which provides the magnetic field, and a set of rotating windings whi ...
Transformer rating
Transformer rating

Electrical Technology 2015
Electrical Technology 2015

... Explain the term human rights in the workplace with reference to the protection of a worker. ...
S1-P210
S1-P210

... same circuit. As Capacitor shows high reactance (31.83 kΩ) at 50 Hz and secondary inductance shows very low (.01Ω) reactance at 50 Hz frequency (TABLE I) so almost all the 50 Hz AC power line Voltage is seized at capacitor C1 and hence we get almost zero ac power line voltage at primary side and iso ...
Aalborg Universitet
Aalborg Universitet

... which is defined as typical fast DC charging, is proposed for commercial and public applications, such as fast charging stations (FCSs) as gas stations today. The chargers for electrical vehicles (EV) battery can be categorized into on-board and off-board charger with unidirectional and bidirectiona ...
SVC Light® enabling strong flicker reduction from a steel plant in the
SVC Light® enabling strong flicker reduction from a steel plant in the

Designing and simulation of multi- converter unified power quality
Designing and simulation of multi- converter unified power quality

... converters. It extends the concept of voltage and power-flow control beyond what is achievable with the known twoconverter UPFC. The simplest GUPFC consists of three converters—one connected in shunt and the other two in series with two transmission lines in a substation. The basic GUPFC can control ...
Chapter 1
Chapter 1

... and bus voltages is seen by the relay as an impedance swing on the R – X plane. If the impedance trajectory enters a relay zone and stays there for sufficiently long time, then the relay will issue a trip decision on power swing. Tripping on power swings is not desirable. We now investigate this phe ...
Final Presentation
Final Presentation

Power System Fundamentals
Power System Fundamentals

Preventing Component Circuit Damage from Above Range Current
Preventing Component Circuit Damage from Above Range Current

... Table 3: MF-MSMF Specifications ...
Evaluates:  MAX4210E, MAX4210A/B/C/D/F MAX4210E Evaluation Kit General Description Features
Evaluates: MAX4210E, MAX4210A/B/C/D/F MAX4210E Evaluation Kit General Description Features

... Jumper JU1 determines how the source voltage is to be applied. Place the shunt across pins 1 and 2 of jumper JU1 to use a divided-down source voltage. The external resistor-divider formed by R2 and R3 provides the voltage division. The second option is to shunt JU1 across pins 2 and 3, allowing the ...
Brochure
Brochure

... combined in series and then applied to the medium voltage side of the transformer to form an RC Snubber circuit. This is a remedy to the symptom not a cure to the problem, which is lower insulation levels in dry-type transformers. Envirotran HDC transformers, having a substantially higher coil Basic ...
THEORY, CONSTRUCTION, AND OPERATION
THEORY, CONSTRUCTION, AND OPERATION

DE-SWADJ3 - Dimension Engineering
DE-SWADJ3 - Dimension Engineering

... unusual or easily changed voltage. The DESWADJ family is pin-compatible with the common 78XX family of linear voltage regulators, and can step down to 3v to 13v with no external circuitry required. It has integrated decoupling capacitors, so external capacitors are not generally necessary. The DE-SW ...
Electric Current File
Electric Current File

Voltage Stability Assessment via Continuation Power Flow Method
Voltage Stability Assessment via Continuation Power Flow Method

... Titik Khawa Abdul Rahman is currently with the The Faculty of Electrical Engineering, Universiti Teknologi MARA, 40450 Shah Alam, Malaysia. She can be reached at takitik@streamyx.com. ...
Suggestions for Grounding a Computer Room
Suggestions for Grounding a Computer Room

Model: BC-12b Switching Type Dual Source Battery Management
Model: BC-12b Switching Type Dual Source Battery Management

... A yellow LED will illuminate for solar power source input voltages over 14 VDC and indicate that the source is capable of charging the battery. As the battery approaches full charge the yellow solar panel LED will dim indicating that excess power from the solar panel is being shunted to ground. A gr ...
Improvement of Electric Power Quality in Distribution System by
Improvement of Electric Power Quality in Distribution System by

... nonlinear loads is further contributing to increased current and voltage harmonics issues. Furthermore, the penetration level of small/large-scale renewable energy systems based on wind energy, solar energy, fuel cell, etc., installed at distribution as well as transmission levels is increasing sign ...
Rules and regs for RGS - Grand Bahama Power Company
Rules and regs for RGS - Grand Bahama Power Company

... been approved by GBPC For each service interconnected, Customer-Generators must also make provision for the appropriate meter socket base(s) or other appropriate metering facilities required to measure the total energy produced by the RGS and energy used by the Customer-Generator. The required meter ...
Wideband vibration energy harvester with high permeability magnetic material Sun
Wideband vibration energy harvester with high permeability magnetic material Sun

... A vibration energy harvester based on a high permeability cantilever beam was demonstrated, which overcomes the limitation of the existing approaches in output power and working bandwidth. Magnetostatic coupling between the vibrating highly permeable beam and bias magnetic field leads to maximized f ...
Level Tuning Fork Sensors
Level Tuning Fork Sensors

SAMPLE Solar, Wind, or Storage IR (Inverter Based Generators)
SAMPLE Solar, Wind, or Storage IR (Inverter Based Generators)

< 1 ... 765 766 767 768 769 770 771 772 773 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report