• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
NCL30000LED2GEVB 180-265 Vac up to 15 Watt Dimmable LED Driver Evaluation Board
NCL30000LED2GEVB 180-265 Vac up to 15 Watt Dimmable LED Driver Evaluation Board

... interest. A 3 A rectifier was selected for the evaluation board to provide low forward drop. Any change to the output rectifier requires verifying the maximum voltage rating is not exceeded. ...
Technical Documentation
Technical Documentation

... SR100 is intended for measuring and monitoring singlephase or three-phase electrical power network. It measures RMS network values and all significant deviations from the nominal values by means of fast sampling of voltage and current signals. There is an option in MiQen Settings Studio software to ...
United States Court of Appeals for the Federal Circuit
United States Court of Appeals for the Federal Circuit

... at a negative voltage with respect to said first power supply.” The claims thus instruct that the well and the substrate must be connected to the respective power supplies at voltages necessary for reversebiasing the junction between the substrate and the well (i.e., “at a negative voltage with resp ...
Mechatronics Module 1 - v3
Mechatronics Module 1 - v3

... there will be a fluctuation in the DC bus voltage during the transition, making control of the motor difficult. A DC/DC converter can be used to maintain relatively constant voltage in the DC bus. It is also used to match battery voltage to motor voltage when the motor is designed to use a higher vo ...
Absolute Maximum ratings - All
Absolute Maximum ratings - All

... easily changed voltage. The DE-SWADJ family is pin-compatible with the common 78XX family of linear voltage regulators, and can provide an output from 1.25v to 13v with no external circuitry required. It has integrated decoupling capacitors, so external capacitors are not generally necessary. The DE ...
P roductfor S olutions
P roductfor S olutions

... namely that wafers break easily and bend a large amount, and that the temperature of the wafer becomes very high when the film is being deposited. ...
Zap! (Electric Discharge) - Here. There. Everywhere.
Zap! (Electric Discharge) - Here. There. Everywhere.

... operate on very similar principles. These generators convert some kind of mechanical energy, such as hot steam rising or water falling, into electrical energy. This small hand generator is made of a few coils of wire around a magnet. When you turn the crank, the wire coils spin around the magnet, wh ...
2SB1427
2SB1427

... otherwise dispose of the same, no express or implied right or license to practice or commercially exploit any intellectual property rights or other proprietary rights owned or controlled by ROHM CO., LTD. is granted to any such buyer. Products listed in this document are no antiradiation design. ...
Cable Splicers
Cable Splicers

... procedures required for 25kV to 230kV cable installation and maintenance techniques. Communicate with other workers to co-ordinate the preparation and completion of work assignments. Report and liaise with management on job progress. RESPONSIBLITIES: ...
“One way” energy recovery system for lifts
“One way” energy recovery system for lifts

Full wave rectifier circuit
Full wave rectifier circuit

... Pen and paper time now folks. In order to keep cost and size down manufacturers would use the smallest capacitor possible to smooth out the power ripple on their rectified circuit. We also want to follow the same principle so we will want to evaluate what time constant we need for the capacitor in ...
Physics 15b PSI Week 3: Current, Resistance, Ohm`s Law 1
Physics 15b PSI Week 3: Current, Resistance, Ohm`s Law 1

... In Chapters 1-3 of Purcell, the potentials and fields associated with stationary charges were studied. Chapter 3 allowed charges to move freely in conductors, but the resulting potentials and electrical fields were only evaluated after the charges stopped moving. Chapters 1-3 were the subject of the ...
Solar Energy Technician (CCC - 0615050517)
Solar Energy Technician (CCC - 0615050517)

... The program is designed to prepare individuals for employment as solar energy technicians, or to provide supplemental training for persons previously or currently employed in the electrical, plumbing or roofing industries. This program prepares individuals to assemble, install, operate, maintain, tr ...
is the DC-grid voltage.
is the DC-grid voltage.

... In order to allow standardization, not all voltage levels are possible. In reality the standardized voltages of 326 VDC, 230 VDC, 120 VDC, 48 VDC, 24 VDC, 12 VDC and finally 6 VDC can be taken into consideration. Many electronic appliances use a DC voltage which is obtained by rectifying the 230 VAC ...
Methods of excitation Separately Excited DC Generator These are
Methods of excitation Separately Excited DC Generator These are

... Here armature current Ia is dividing in two parts, one is shunt field current Ish and another is load current IL. So, Ia=Ish + IL The effective power across the load will be maximum when IL will be maximum. So, it is required to keep shunt field current as small as possible. For this purpose the re ...
ANALYSIS OF BROADBAND GAN SWITCH MODE CLASS
ANALYSIS OF BROADBAND GAN SWITCH MODE CLASS

PR 151-2015/ROHM
PR 151-2015/ROHM

High-Efficiency AC Power Distribution for Data Centers
High-Efficiency AC Power Distribution for Data Centers

Vacuum Tube Power Amps
Vacuum Tube Power Amps

... of four mono-block power amplifiers integrated into one chassis, using the same power supply. Diodes D1 and D2 were used for full-wave rectification (see Figure 5 5). For this reason a Standby/Operate switch, SW2, is connected between the cathodes of the EL34s and ground with a 10-Ω, en10-W resistor ...
PDF Download(PDF Type, 13Kbyte)
PDF Download(PDF Type, 13Kbyte)

... increase in drive current and one order of magnitude reduction in leak current were confirmed when the back-gate bias was applied. Further, the target threshold voltage for low-power applications were achieved by employing the developed tunable threshold voltage technology. The next step will be to ...
EBPLED Emergency Battery Packs
EBPLED Emergency Battery Packs

... 14W unit) and adjusts output current to provide constant wattage to the fixture, ensuring compatibility with a wide range of LED fixtures. ...
Designing to Protect MAX2140`s Internal ESD
Designing to Protect MAX2140`s Internal ESD

... Designing to Protect MAX2140's Internal ESD Diode During Nonstandard Operation * Dec 23, 2005 Abstract: The MAX2140 SDARS receiver can experience internal ESD diode failure during a hot-plug operation (connection or disconnection with power applied), which is not a standard operation for this device ...
SG6105 ABSTRACT FEATURE OVERVIEW PIN
SG6105 ABSTRACT FEATURE OVERVIEW PIN

... UVAC is asserted, the SG6105 will enter hiccup mode instead of latch mode. The outputs will be turned off, and turned back on after a set time (typically three seconds). This anti-lockout function is particularly important during brownout situations. ...
AV500 Passthrough Powerline WiFi Kit TL-WPA4230P KIT Features
AV500 Passthrough Powerline WiFi Kit TL-WPA4230P KIT Features

... Multiple Ethernet ports allow your TVs, game consoles, or PCs connect to the Internet Easy-to-install, just plug and play 128-bit AES encryption easily at a push of "Pair" Button Up to 300-meter range over the household power circuit Supports IGMP managed multicast IP transmission, optimizing IPTV s ...
DSL  Primary Switched Battery Charging and Power Supply Unit GL1024
DSL Primary Switched Battery Charging and Power Supply Unit GL1024

... batteries and/or for supplying 24V DC circuits. The charging unit is especially suitable for use with diesel generators, where operating safety and long-term stability are necessary. The primary clocked switching power supply with 100kHz technology is intended for use on the top-hat rail due to its ...
< 1 ... 758 759 760 761 762 763 764 765 766 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report