• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
View/Download-PDF - International Journal of Computer Science
View/Download-PDF - International Journal of Computer Science

Comparison of AIS and GIS Grid Station
Comparison of AIS and GIS Grid Station

Manual
Manual

... can be positioned beside, but not on top, of the power amplifiers. Because there are no controls (other than power switches) on the crossover and power amplifiers it may be convenient in some installations to position them remote from the sources and preamplifier. The Linn LK1 preamplifier is capabl ...
幻灯片 1
幻灯片 1

... electric motors, which is important for sizing inverters, wires, fuses, and other ancillary electrical components in the system ...
Step Down Transformer By Sultan Salahuddin
Step Down Transformer By Sultan Salahuddin

... www.BZUpages.com Bahuddin Zakariya University Multan, Pakistan ...
FENOC%
FENOC%

... REV NO. ...
HARMONICS - Understanding the Facts - Part 3
HARMONICS - Understanding the Facts - Part 3

... When transformers are first energized, the current drawn is different from the steady state condition. This is caused by the inrush of the magnetizing current. The harmonics during this period varies over time. Some harmonics have a negligible value for part of the time, and then increase for a whil ...
Amplifier Construction
Amplifier Construction

... Amplification system for this project has been heavily customised. I started with a broad assessment of power output requirements, outlined in the paper http://www.bodziosoftware.com.au/Power_Amplifiers.pdf and then proceeded with the design of the amplifiers (or rather the selection of amplifier mo ...
Custom IC Conf 93 — Cost, Power, and Parallelism in
Custom IC Conf 93 — Cost, Power, and Parallelism in

... portable computing products, the weight and limited operating time of the portable power source implies another kind of cost to the user. The option of increasing the energy density by using more exotic batteries is available, but at a very high cost. In new generation RISCbased desktop systems, get ...
5324 Hwrk Probs 31-35 - The College of Engineering at the
5324 Hwrk Probs 31-35 - The College of Engineering at the

Real Time Modeling and Simulation of Cyber-Power System
Real Time Modeling and Simulation of Cyber-Power System

Microcontroller Based PWM Controlled Four Switch Three Phase
Microcontroller Based PWM Controlled Four Switch Three Phase

... microcontroller are fed to the gate of MOSFETs of FSTPI through the driver circuit to drive the IM. 2.1 Principle of FSTPI operation The power circuit of the FSTPI fed IM drive is shown in Fig. 1. The circuit consists of 4-switches S1 , S 2 , S3 and S 4 and split capacitors C1 and C2 . The 3-phase A ...
Solenoids - Johnson Electric
Solenoids - Johnson Electric

Elec467 Power Machines & Transformers
Elec467 Power Machines & Transformers

... Characteristics of motor types This graph is actually two graphs that share the x-axis in common. Speed and torque characteristics of the three DC motor types are compared. A Series motor is the most non-linear but are capable of extremely high torque at low speeds (with high current). Whatever a s ...
2012S
2012S

... b) The hysteresis and eddy current losses of a transformer are 300 W and 250 W, respectively, if the supply voltage is 500 V at 50 Hz. Find the hysteresis loss and eddy current loss if the supply voltage is 1,000 V& 100 Hz. ...
Low cost data communications equipment for use on the electric
Low cost data communications equipment for use on the electric

... Commutation: When applied to thyristors, refers to the stopping of conduction. Cycloconverter: A static power frequency changer that uses controlled rectifiers to generate the new frequency at the output. Distribution system: That portion of the electric power system used to connect individual custo ...
PART 1 – GENERAL - Hammond Power Solutions
PART 1 – GENERAL - Hammond Power Solutions

... Store and handle in strict compliance with manufacturer’s instructions and recommendations. Protect from potential damage from weather and construction operations. Store so condensation will not form on or in the transformer housing and if necessary, apply temporary heat where required to obtain sui ...
ppt
ppt

Lockheed Martin Challenge - Senior Design
Lockheed Martin Challenge - Senior Design

... • C and CS mount lens compatible - large variety of varifocal lenses from which to choose • Auto-iris compatible - the ability to dynamically adjust to changing light conditions during flight • NTSC video output using a coaxial connection (both standard – allows for simplicity of design and video tr ...
ECOTAP VPD The new compact class for distribution transformers
ECOTAP VPD The new compact class for distribution transformers

Using a Supercapacitor to Power Wireless Nodes from a 3V Button
Using a Supercapacitor to Power Wireless Nodes from a 3V Button

Welding machines: V and HB series IGBTs on two
Welding machines: V and HB series IGBTs on two

... The two-switch forward converter (also known as asymmetrical half-bridge forward converter) is a popular topology often used in industrial welding machines with low-tomedium power requirements. The inverter stage in this hard-switched forward topology includes two transistor switches and two fast re ...
X4 Drives Specification Sheet
X4 Drives Specification Sheet

... Control System: V/Hz or Sensorless Vector Control. Carrier frequency = 1 to 6 kHz programmable Output Voltage: 0 to 100% of line voltage, 3 phase ...
9
9

... Switch-mode power supplies are employed in dc voltage step-up or step-down, as several dc-dc converters can be used for this purpose. Soft switching PWM topologies [3, 4, 5,6] have advantages such as low switching losses, Constant frequency of operation and simple control, However they have load lim ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

... factor regulator in the discontinuous conduction mode and half bridge resonant series resonant inverter. The proposed topology has benefits of closed loop error checking, lesser components, higher power density and lesser conduction losses due to the absence of an input diode in the current path dur ...
< 1 ... 712 713 714 715 716 717 718 719 720 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025