• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Maths - where is it used in Engineering?
Maths - where is it used in Engineering?

... Thyristors  are  solid‐sate  semiconductors  devices  (similar  to  diodes)  that  act  as  switches. They are mainly used  to control alternating  currents  where high voltages  and  currents  are  involved.  Integration  can  be  used  to  design  thyristors  for  applications such as shown below. ...
Aalborg Universitet Trintis, Ionut; Ghimire, Pramod; Munk-Nielsen, Stig; Rannestad, Bjørn
Aalborg Universitet Trintis, Ionut; Ghimire, Pramod; Munk-Nielsen, Stig; Rannestad, Bjørn

... Temperature is one of a key parameter considered in design of power converters. Generally, manufacturer provides maximum operating virtual junction temperature for semiconductor devices. State of the art power modules used in wind power applications are safe to operate until 150◦C. This however, doe ...
Basic Series 40 Information
Basic Series 40 Information

... Cimco Electronics, Inc. PHONE (724) 528-9559 FAX ...
AN-1434 Crest Factor Invariant RF Power Detector
AN-1434 Crest Factor Invariant RF Power Detector

... There is a linear response from –7 dBm to +13 dBm when the power is represented in mW. This linear characteristic provides an added advantage for power amplifier detection voltage calibration. In the production process, VDETECTED is measured at two different power levels (2-Point), say at the power ...
Engineering Challenges in Wind Turbine Design
Engineering Challenges in Wind Turbine Design

... Alternative #2: detailed time-domain simulations • Performed in an EMT-type program (EMTP, ATP, PSCAD, etc.) • Requires detailed hardware and control model – Such data are usually considered quite proprietary – “Generic” models are quite meaningless • Not well suited for large system studies • Requi ...
Average Power Balancing Control of a STATCOM based on the
Average Power Balancing Control of a STATCOM based on the

... instantaneous reactive power (q) as long as there is negativesequence component in system. The main objective of proposed control method is to regulate three cluster dc voltages and to inject the required reactive power into the grid. These can be achieved by managing the average active power flow a ...
Aalborg Universitet
Aalborg Universitet

... extract more power from wind [1]. As the wind turbine size increases, the flexibility associated with the wind turbine drive train system also increases and so does the influences that it has on the electrical transient performance of the wind turbine. In addition, as the penetration of wind power c ...
CPC1945Y - IXYS Integrated Circuits Division
CPC1945Y - IXYS Integrated Circuits Division

... • Solenoids • Motors • Heaters ...
2SB1707
2SB1707

... otherwise dispose of the same, no express or implied right or license to practice or commercially exploit any intellectual property rights or other proprietary rights owned or controlled by ROHM CO., LTD. is granted to any such buyer. Products listed in this document are no antiradiation design. ...
RD06HHF1 数据资料DataSheet下载
RD06HHF1 数据资料DataSheet下载

... 2.RA series products (RF power amplifier modules) and RD series products (RF power transistors) are designed for consumer mobile communication terminals and were not specifically designed for use in other applications. In particular, while these products are highly reliable for their designed purpos ...
BP5718A12
BP5718A12

L-20(NKD)
L-20(NKD)

... It may be noted that the magnitudes of the phase or line voltage and also phase current are assumed to be constant, which means that the magnitude of the load impedance (inductive) is constant, but the angle, φ varies as stated. As the lagging power factor decreases from 1.0 to 0.5, with φ increasi ...
Analysis of Transient Power-angle Characteristic for Synchronous
Analysis of Transient Power-angle Characteristic for Synchronous

... synchronous machines after they have been perturbed. If the perturbation does not involve any net change in power, the machines should return to their original state. If an unbalance between the supply and demand is created by a change in load, in generation, or in network conditions, a new operatin ...
PDF
PDF

... converter, where its output voltage gets varied as per its duty cycle. It’s very important to select the proper dc-dc converter which plays vital role for maximum power point tracking operation. There are many factors such as cost, efficiency, flexibility and energy flow which are considered for sel ...
Hardware
Hardware

... Rcs1 and Rcs2 and varies depending on the size of the power supply and is the difference between the 800 mA power supplies and the 150 mA supplies. These current sources affect the current mesurements of the power supply; this needs to be taken into consideration when measuring the current. The two ...
Owner`s Guide for the Bass Amplifier
Owner`s Guide for the Bass Amplifier

Power-Performance Simulation and Design Strategies for Single
Power-Performance Simulation and Design Strategies for Single

... executing at frequency (f) for greatly reduced overall power. Spatial voltage scaling seeks to find not only n, but a set of fi, one for each processor in the system. Thus, n processors may be substituted for a single processor where the set of processors has a set of frequencies, { f1; . . . ; fn } ...
low power low voltage operation of operational amplifier
low power low voltage operation of operational amplifier

... The increasing demand for high performance, battery-operated, system-on-chip (SoC) in communication and computing has shifted the focus from traditional constraints (such as area, performance, cost and reliability) to power consumption. With the increasing integration level, energy consumption has b ...
CIRCUIT FUNCTION AND BENEFITS
CIRCUIT FUNCTION AND BENEFITS

... the "Circuits from the Lab". Information furnished by Analog Devices is believed to be accurate and reliable. However, "Circuits from the Lab" are supplied "as is" and without warranties of any kind, express, implied, or statutory including, but not limited to, any implied warranty of merchantabilit ...
AN-376 Logic-System Design Techniques Reduce Switching
AN-376 Logic-System Design Techniques Reduce Switching

Zahn, M., and J.K. Skinner, Novel Self-excited Alternating Operation of Coupled Commutator Machines, Journal of the Franklin Institute 296, 1-13, 1973
Zahn, M., and J.K. Skinner, Novel Self-excited Alternating Operation of Coupled Commutator Machines, Journal of the Franklin Institute 296, 1-13, 1973

... reflects itself in the equivalent circuit of Fig. 1 as the inductances as well as the speed coefficient G are not constant but functions of the currents. Thus for time-varying conditions, such as during the voltage build-up in a self-excited generator, the differential equations are nonlinear. For t ...
Simple Regulated Supply (SRS)
Simple Regulated Supply (SRS)

Two-Way Current-Combining w-Band Power Amplifier in 65
Two-Way Current-Combining w-Band Power Amplifier in 65

... Any amplitude and phase mismatches degrade power-combining efficiency. Some system calibration method scan be adopted to mitigate mismatch issues. However, the schemes are normally band-limited and impose design complexities. Therefore, channel symmetry becomes one of the key merits in power combine ...
P2000 SMS CKM-MR50 Authentic Mercury Terminal Module
P2000 SMS CKM-MR50 Authentic Mercury Terminal Module

... SPF1I100-1I00 or SPF1I300-1J00E4M shall be powered through the CKM-F8P power distribution module. 3. Transient protection devices that are installed must not be removed or defeated. 4. Do not connect equipment to an AC power source that is controlled by a switch. 5. A 1.5Kohm/750ohm custom end-of-li ...
3-Way Solenoid
3-Way Solenoid

... The BERMAD S-400-3W is a compact 3-Way Solenoid Pilot Valve that can control valves independently or in combination with other control circuit accessories. It excels in its low power consumption and low sensitivity to dirt and voltage variations. The Model S-400-D-3W-BB, due to its internal diode re ...
< 1 ... 645 646 647 648 649 650 651 652 653 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report