• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Power Management in Portable Systems Using MAX II CPLDs
Power Management in Portable Systems Using MAX II CPLDs

... MAX II devices have many power system characteristics that are beneficial to portable applications. The MAX II device has two core power options. The most useful is the standard device that has a built-in core voltage regulator. The 180-nm core internal VCC requires a 1.8 V power supply. MAX II devi ...
APX-100 amplifier The BEAG is a successful product with a 1970s
APX-100 amplifier The BEAG is a successful product with a 1970s

... The 8 Ohm secondary of the output transformer will output less voltage than the original output transformer. Thus the resistance of R25 should be reduced to 5K6, negative feedback will will remain to work unchanged. The capacitor C10 and resistors in parallel are to be replaced with a value of 390pF ...
Transformer Basics
Transformer Basics

... Insulation Self restoring insulation recovers after a flashover – external such as air switches, insulators, external surfaces of bushings (defined at standard atmospheric conditions)  Non-self restoring insulation does not recover after a flashover – enclosed oil, paper, gas, air systems such as ...
Transformers
Transformers

... An A.C. device used to change high voltage low current A.C. into low voltage high current A.C. and vice-versa without changing the frequency In brief, 1. Transfers electric power from one circuit to another 2. It does so without a change of frequency 3. It accomplishes this by electromagnetic induct ...
Engineering Presentation
Engineering Presentation

...  Self Diagnostics - LED Indicators Per Phase.  Optional: Surge Counter, Dry Contact Form C and Fault Test Button. ...
Transformers
Transformers

TI2332233228
TI2332233228

... AC power at a different frequency. An alternative approach is the Matrix Converter (MC) technology [1], where the input AC power is directly converted to output AC power using a matrix of bidirectional switching elements, Fig. 1. Both topologies can provide controllable sinusoidal output voltages an ...
ELM 200 Electric Circuits I
ELM 200 Electric Circuits I

... Cognitive: Comprehend principles and concepts related to DC electricity. Performance: Apply principles of DC electricity. Affective: Value the importance of adhering to policy and procedures related to DC electricity STUDENT OBJECTIVES Condition Statement: Unless otherwise indicated, evaluation of s ...
Power Distribution Control Coordinating Ultracapacitors and
Power Distribution Control Coordinating Ultracapacitors and

... One possibility to ease the power burden on batteries and fuel cells is to use ultra-capacitors as load-leveling devices. The high power density of ultra-capacitors allows a significant reduction in the power fluctuations imposed on the remaining electrical system; however, the same ultra-capacitors ...
Robustness Against Parasitics By SOI
Robustness Against Parasitics By SOI

... ICs based on standard Silicon technology exhibit low tolerance to negative voltages presented to their inputs and outputs. A small negative voltage in the range of -0.8 to -1 V at one of the IC pins may result in uncontrolled substrate currents. The substrate currents are injected for instance by a ...
Voltage-Source Active Power Filter Based on Multilevel Converter
Voltage-Source Active Power Filter Based on Multilevel Converter

... ODERN power electronics have contributed a great deal to the development of new powerful applications and industrial solutions; but at the same time, these advances have increased the harmonic contamination present in line currents, which ends up distorting the voltage waveforms. Some power electron ...
Model MS Super 1E
Model MS Super 1E

... 2. Use minimum 90˚ C/300V rated insulated copper conductors only, type THHN or equal sized in accordance with National Electrical Code and local electrical code for the Amps in Ampere Chart. If allowed by code, NM cable may require a larger wire size than as listed on the chart. 3. Connect suitably ...
Integration of IEC 61850 GSE and Sampled Value Services
Integration of IEC 61850 GSE and Sampled Value Services

operating instructions
operating instructions

MCW100C, E Time Proportional Rotary Position
MCW100C, E Time Proportional Rotary Position

Process Variation Aware Synthesis of Application-Specific MPSoCs to Maximize Yield
Process Variation Aware Synthesis of Application-Specific MPSoCs to Maximize Yield

... variations on performance and power. But in addition to WID variations, we also consider D2D variations in our test set of N VT-maps, which prior work [13]-[16] does not consider. A few prior works propose frameworks for variation-aware synthesis of MPSoCs with VIs, to optimize computation and commu ...
LTC4400-1/LTC4400-2 - RF Power Controllers with 450kHz Loop BW and 45dB Dynamic Range.
LTC4400-1/LTC4400-2 - RF Power Controllers with 450kHz Loop BW and 45dB Dynamic Range.

... pulse at the start of the ramp to quickly bring the VPCA/B output to the threshold voltage. This can generally be achieved with DAC programming. The magnitude of the pulse is dependent on the RF amplifier characteristics. Power ramp sidebands and power/time are also a factor when ramping to zero pow ...
DS507 Manual - Dyne Systems
DS507 Manual - Dyne Systems

Chapter 8 Power Supplies
Chapter 8 Power Supplies

Chapter 8 Power Supplies
Chapter 8 Power Supplies

Alcon Electronics Company Presentation
Alcon Electronics Company Presentation

... E mail: mail@alconelectronics.com Website: www.alconelectronics.com ...
Dynamic Current Profiling
Dynamic Current Profiling

... predict a device’s battery life based on its power consumption. Stochastic battery modeling is ideal for embedded system designs that have a dynamic current profile, such as a design that goes in and out of sleep/ idle modes or a device that has sudden current pulses, like a power amplifier. This type ...
Test Circuits for 3-D Systems Integration
Test Circuits for 3-D Systems Integration

PQM (Power  Quality  Meter) Features Introduction HC 6030
PQM (Power Quality Meter) Features Introduction HC 6030

... low control functions to be added for specific applications. This includes basic alarm on over / under current or voltage, ...
Unit C 7-5
Unit C 7-5

... are three separate and distinct singlephase currents, which are combined so they can be transmitted over three or four wires. This greatly increases machine operating power. ...
< 1 ... 635 636 637 638 639 640 641 642 643 ... 1128 >

Power engineering



Power engineering, also called power systems engineering, is a subfield of energy engineering that deals with the generation, transmission, distribution and utilization of electric power and the electrical devices connected to such systems including generators, motors and transformers. Although much of the field is concerned with the problems of three-phase AC power – the standard for large-scale power transmission and distribution across the modern world – a significant fraction of the field is concerned with the conversion between AC and DC power and the development of specialized power systems such as those used in aircraft or for electric railway networks. It was a subfield of electrical engineering before the emergence of energy engineering.Electricity became a subject of scientific interest in the late 17th century with the work of William Gilbert. Over the next two centuries a number of important discoveries were made including the incandescent light bulb and the voltaic pile. Probably the greatest discovery with respect to power engineering came from Michael Faraday who in 1831 discovered that a change in magnetic flux induces an electromotive force in a loop of wire—a principle known as electromagnetic induction that helps explain how generators and transformers work.In 1881 two electricians built the world's first power station at Godalming in England. The station employed two waterwheels to produce an alternating current that was used to supply seven Siemens arc lamps at 250 volts and thirty-four incandescent lamps at 40 volts. However supply was intermittent and in 1882 Thomas Edison and his company, The Edison Electric Light Company, developed the first steam-powered electric power station on Pearl Street in New York City. The Pearl Street Station consisted of several generators and initially powered around 3,000 lamps for 59 customers. The power station used direct current and operated at a single voltage. Since the direct current power could not be easily transformed to the higher voltages necessary to minimise power loss during transmission, the possible distance between the generators and load was limited to around half-a-mile (800 m).That same year in London Lucien Gaulard and John Dixon Gibbs demonstrated the first transformer suitable for use in a real power system. The practical value of Gaulard and Gibbs' transformer was demonstrated in 1884 at Turin where the transformer was used to light up forty kilometres (25 miles) of railway from a single alternating current generator. Despite the success of the system, the pair made some fundamental mistakes. Perhaps the most serious was connecting the primaries of the transformers in series so that switching one lamp on or off would affect other lamps further down the line. Following the demonstration George Westinghouse, an American entrepreneur, imported a number of the transformers along with a Siemens generator and set his engineers to experimenting with them in the hopes of improving them for use in a commercial power system.One of Westinghouse's engineers, William Stanley, recognised the problem with connecting transformers in series as opposed to parallel and also realised that making the iron core of a transformer a fully enclosed loop would improve the voltage regulation of the secondary winding. Using this knowledge he built a much improved alternating current power system at Great Barrington, Massachusetts in 1886. In 1885 the Italian physicist and electrical engineer Galileo Ferraris demonstrated an induction motor and in 1887 and 1888 the Serbian-American engineer Nikola Tesla filed a range of patents related to power systems including one for a practical two-phase induction motor which Westinghouse licensed for his AC system.By 1890 the power industry had flourished and power companies had built thousands of power systems (both direct and alternating current) in the United States and Europe – these networks were effectively dedicated to providing electric lighting. During this time a fierce rivalry in the US known as the ""War of Currents"" emerged between Edison and Westinghouse over which form of transmission (direct or alternating current) was superior. In 1891, Westinghouse installed the first major power system that was designed to drive an electric motor and not just provide electric lighting. The installation powered a 100 horsepower (75 kW) synchronous motor at Telluride, Colorado with the motor being started by a Tesla induction motor. On the other side of the Atlantic, Oskar von Miller built a 20 kV 176 km three-phase transmission line from Lauffen am Neckar to Frankfurt am Main for the Electrical Engineering Exhibition in Frankfurt. In 1895, after a protracted decision-making process, the Adams No. 1 generating station at Niagara Falls began transmitting three-phase alternating current power to Buffalo at 11 kV. Following completion of the Niagara Falls project, new power systems increasingly chose alternating current as opposed to direct current for electrical transmission.Although the 1880s and 1890s were seminal decades in the field, developments in power engineering continued throughout the 20th and 21st century. In 1936 the first commercial high-voltage direct current (HVDC) line using mercury-arc valves was built between Schenectady and Mechanicville, New York. HVDC had previously been achieved by installing direct current generators in series (a system known as the Thury system) although this suffered from serious reliability issues. In 1957 Siemens demonstrated the first solid-state rectifier (solid-state rectifiers are now the standard for HVDC systems) however it was not until the early 1970s that this technology was used in commercial power systems. In 1959 Westinghouse demonstrated the first circuit breaker that used SF6 as the interrupting medium. SF6 is a far superior dielectric to air and, in recent times, its use has been extended to produce far more compact switching equipment (known as switchgear) and transformers. Many important developments also came from extending innovations in the ICT field to the power engineering field. For example, the development of computers meant load flow studies could be run more efficiently allowing for much better planning of power systems. Advances in information technology and telecommunication also allowed for much better remote control of the power system's switchgear and generators.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report