• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
RadioRA 2 Architectural RF GrafikTT Local Controls product specifications
RadioRA 2 Architectural RF GrafikTT Local Controls product specifications

... Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2. Surge Protection Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Cir ...
recessed downlight housings
recessed downlight housings

... voltage DHH housing. When circuiting Lucifer 12-volt recessed downlights either singly or in series with a remote transformer, it must be remembered that a lower voltage signifies a higher current in amperes. Therefore, secondary fusing based on a multiplier of 1.25% (NEC) must be used. The conducto ...
Users Guide for the Non
Users Guide for the Non

... The VA ratings on transformers is also a consideration. Within reason, a larger transformer has more constant regulation under load, but this chip operates very successfully without extremely large transformers. Many have successfully used 160VA transformers, while the 220VA range seems to be adequa ...
3. Fundamentals of Electrical Distribution
3. Fundamentals of Electrical Distribution

... Universally accepted symbols frequently have additional information provided near the symbol. This distinguishes like symbols from one another. The following examples are typical: Identifies the drawout circuit breaker represented by the symbol as a 1200 ampere circuit breaker. Identifies the fixed ...
Grounding and Bonding - Peck Ormsby Construction
Grounding and Bonding - Peck Ormsby Construction

... Provide bonding jumpers and wire, grounding bushings, clamps and appurtenances required for complete grounding system to bond equipment and raceways to equipment grounding conductors. ...
Design and Analysis of High-Voltage Transformer for HID Lamp Igniter
Design and Analysis of High-Voltage Transformer for HID Lamp Igniter

... In HV or Pulse transformer applications, the key issue is to prevent the core saturation. There are two main types for saturation: volt-sec saturation and NI value limitation. Because the ballast tries to ignite the lamp more than once for reliability, the HV transformer should be designed not to sa ...
floating measurements
floating measurements

... (earth) potential. This measurement is often referred to as a differential measurement. “Signal common” may be elevated to hundreds of volts from earth. In addition, many of these differential measurements require the rejection of high common-mode signals*1 in order to evaluate low-level differentia ...
Fuses - iGCSE Science Courses
Fuses - iGCSE Science Courses

... Mains electricity 1. If a fault develops (eg. Live touches the earthed metal case) then a big current flows in through the live, through the case and out down the earth wire ...
Comparative analysis of lightning overvoltages in distribution lines
Comparative analysis of lightning overvoltages in distribution lines

... • Tests and many years of observations of atmospheric discharges show that peak value and steepness of wave front are random values of negligible correlation. This means that these parameters can be analyzed independently. • Analysis results of computer simulations, laboratory tests, and measurement ...
Impact of Bonding Requirements for CSST on LP
Impact of Bonding Requirements for CSST on LP

... Lightning Induced Piping Damage • Lightning does not discriminate. It will damage all piping materials and systems. • Damage is attributed to arcing caused by a difference in voltage build-up between the grounded electrical system and any other electrically conductive pathway. • Gas system componen ...
LX Owner`s Manual
LX Owner`s Manual

... For maximum light output and lamp life, the goal when installing low voltage systems is to provide each lamp with between 10.5 and 11.5 volts and LED with 10 to 15 volts. To stay within a 0.5 to 1.0 volt differential between the first light and the last light on a given circuit (while LED lights can ...
PRESENTATION NAME
PRESENTATION NAME

... edges) and the sodium, present in the glass ...
(ELD Fusion ®) : Word ()
(ELD Fusion ®) : Word ()

... Scope: When required, at areas where the membrane will be covered with overburden, the ELD Technician will install a permanent On-demand Electronic Leak Detection System to facilitate future Low Voltage Vector Mapping with the overburden in place. The ELDS will consist of trace wire loops installed ...
3-Phase Circuits
3-Phase Circuits

... In general, three-phase systems are preferred over single-phase systems for the transmission of power for many reasons. 1. Thinner conductors can be used to transmit the same kVA at the same voltage, which reduces the amount of copper required (typically about 25% less). 2. The lighter lines are eas ...
Wiring Diagrams Wiring Diagrams Wiring Diagrams Wiring
Wiring Diagrams Wiring Diagrams Wiring Diagrams Wiring

... Wiring Diagrams explain how a circuit works All electrical circuits need Power (positive voltage), conductors, controls, loads. To understand how a circuit works you must trace powerflow through the conductors, controls, and loads. ...
Reference Materials - Jefferson Electric
Reference Materials - Jefferson Electric

... selected to withstand as much as 25 times primary rated current for .01 second, and 12 times primary rated current for .1 second. Storage should be avoided, but if this is not possible, the transformer must be protected against moisture and contaminants. Condensation and moisture can be reduced with ...
Automatic Meter Reading
Automatic Meter Reading

... Project Manager and CFO co-own project Operations really wanted AMR TWACS a great product - Commissioning was highly successful and exceeded all expectations ...
Page 1 - Madeley High School
Page 1 - Madeley High School

... In the National Grid, very large step-up transformers link power stations to the transmission cables. A transformer used for this purpose has 800 turns on its primary coil and 12 800 turns on its secondary coil. The p.d. (potential difference) across its primary coil is 25 kV. Use the equation in th ...


... letters that are on the outside of a building as well as on the inside of a building in plenum spaces without conduit. Specifically engineered for use where exposed to UV (sunlight) or moisture. Huge savings in both installation and labor costs are realized compared to using Class 2 or Class 3 wires ...
Hola Agustin - Portal UniMAP
Hola Agustin - Portal UniMAP

... Both of these transformers are designed to be immersed in insulating oil in a steel tank. In addition to having insulating properties, the oil conducts heat from the core and coils to the surface of the tank where it is given off to the surrounding air. Connections from the transformer coils to the ...
Inter-system Ground Noise: Causes and Effects
Inter-system Ground Noise: Causes and Effects

... protection equipment is designed to protect the load or loads, which are attached. In the ideal case, no connection point to the computer exists except for the AC power cord. This allows the power protection equipment complete control over noise or transient voltage events that could enter the compu ...
Unit C 7-5 - Edhole.com
Unit C 7-5 - Edhole.com

... the case of three-phase current, the same pattern exists, except that there are three separate and distinct single-phase currents, which are combined so they can be transmitted over three or four wires. ...
Unit C 7-5
Unit C 7-5

... the case of three-phase current, the same pattern exists, except that there are three separate and distinct single-phase currents, which are combined so they can be transmitted over three or four wires. ...
Low cost data communications equipment for use on the electric
Low cost data communications equipment for use on the electric

... experiments signaled by means of momentary interruptions of the supply (7). ...
SUBARTICLE 785-2.1 (of the Supplemental Specifications) is deleted and the... substituted: 785 INTELLIGENT
SUBARTICLE 785-2.1 (of the Supplemental Specifications) is deleted and the... substituted: 785 INTELLIGENT

... 785-5.3.4 Grounding Installation: Install all grounds for the equipment shelter on the side of the building that utilities, communication cables, and fiber enter. Install the main ground bar on a suitable wall of the building. Connect all earth grounds to this point, including the grounding system f ...
< 1 ... 25 26 27 28 29 30 31 32 33 ... 79 >

Single-wire earth return



Single wire earth return (SWER) or single wire ground return is a single-wire transmission line which supplies single-phase electrical power from an electrical grid to remote areas at low cost. Its distinguishing feature is that the earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire) to act as a return path. Single-wire earth return is principally used for rural electrification, but also finds use for larger isolated loads such as water pumps. It is also used for high-voltage DC over submarine power cables. Electric single-phase railway traction, such as light rail uses a very similar system. It uses resistors to earth to reduce hazards from rail voltages, but the primary return currents are through the rails.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report