• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Fault Finding
Fault Finding

... Proceed to your cut-out switches and switch off the first cut-out switch and take a reading. If the voltage is good, this first section of fence line is sound. Proceed to the next cut-out and repeat the procedure until the section of fence line that has the fault is located. Then locate the fault in ...
HEWITT PYROMETERS Installation Instructions
HEWITT PYROMETERS Installation Instructions

... E-MAIL: sales@hewittindustries.com ...
Distribution Systems, Substations, and Integration of Distributed
Distribution Systems, Substations, and Integration of Distributed

... in lower Manhattan. By 1887, there were 121 Edison power stations in the United States delivering DC electricity to customers. These early power plants ran on coal or water. Centralized power generation became possible when it was recognized that alternating current (AC) electricity could be transpo ...
Instrument Transformers
Instrument Transformers

... of cores or windings can also be easily implemented, even after years, to meet new requirements such as additional metering, thus offering long-term b ­ enefits. ...
uss dry type transformer
uss dry type transformer

... Each coil assembly shall be vacuum pressure impregnated in polyester varnish. The VPI process shall apply a one (1) cycle polyester protective shield of varnish to the coils shall effectively impregnate the entire core and coil assembly that results in a unit which is virtually impermeable to moistu ...
ABB Transformers - cablejoints.co.uk
ABB Transformers - cablejoints.co.uk

... connected to open delta must have dn terminal earthed only on one of three transformers (earthing screws at dn terminals of others two transformers have to be removed). When the secondary of transformer is interconnected, there should be only one grounded point to prevent accidental paralleling with ...
Lightning-Induced Overvoltages
Lightning-Induced Overvoltages

... in Fig. 3b. The line is a lossless, 1-km long, 10-m high overhead wire, matched at its two terminals. The lightning strike is located at 50 m from the line center and equidistant to the line terminations. As it can be seen by this figure, lightning-induced voltages are characterized, in general, by ...
Wire Recorder3
Wire Recorder3

... We  then  took  the  recording  head  out  of  an  old  tape  recorder.  With  this  type   of  head  we  were  able  to  record  and  playback  with  only  1  level  of  amplification  when   recording  with  100  V  from  our ...
Application of Current Differential Protection to Tapped
Application of Current Differential Protection to Tapped

... differential protection to tapped transmission lines without measurements at the tap point (-s). ...
UFC 3-520-01 Interior Electrical Systems
UFC 3-520-01 Interior Electrical Systems

... Engineering Command (NAVFAC), and Air Force Civil Engineer Support Agency (AFCESA) are responsible for administration of the UFC system. Defense agencies should contact the preparing service for document interpretation and improvements. Technical content of UFC is the responsibility of the cognizant ...
transformer protection
transformer protection

... Transformer magnetizing or inrush current depends on several factors including the transformer’s design, the amount of residual flux in the transformer core at the instant the transformer is energized, the point on the voltage wave at which the switch is closed, and the characteristics of the electr ...
VII. Classification of Transmission Line Surge Arrester
VII. Classification of Transmission Line Surge Arrester

... are a usual reason for unscheduled supply interruption in the modern power system, In an effort to maintain failure rates in a low level, providing high power quality and avoiding damages and disturbances, plenty of lightning performance estimation studies have been conducted and several design meth ...
LECTURE 34 HIGH FREQUENCY TRANSFORMER A. Transformer
LECTURE 34 HIGH FREQUENCY TRANSFORMER A. Transformer

... as well as insulation between high voltage and low voltage windings. In practice, only about 50% of the window area can actually carry active conductor, This fraction is called the fill factor. In a two-winding transformer, this means that each winding can fill not more than 25% of the total wire wi ...
Phase-shifting Transformer Modeling in PSS®E
Phase-shifting Transformer Modeling in PSS®E

... For short circuit calculations the phase-shifting transformer model for the negative sequence network will employ the same leakage impedance used in the load flow calculations, but the sign of the phase shift angle will be reversed. Hence, if the phase shift angle is +Φ in the positive sequence netw ...
Challenges of Dimming LED Loads on ELV and MLV
Challenges of Dimming LED Loads on ELV and MLV

... Wave form symmetry is particularly important to the performance of MLV systems. If the dimmer does not feed the transformer a perfectly symmetrical forward-phase signal, or the output rectifier does not provide a perfectly-symmetrical output, or the LED driver circuit doesn’t draw current symmetrica ...
4.0 operation - Always On UPS Systems
4.0 operation - Always On UPS Systems

... Please pay attention to the warning boxes to ensure the safe and proper use of your SHP. Ignoring these warnings could be hazardous to the user and/or the equipment. 2.1. Theory of Operation The “SHP” is designed as a TVSS (Transient Voltage Surge Suppressor) for low voltage distribution equipment o ...
Distribution Transformers and EMC
Distribution Transformers and EMC

... These three-dimensional fields are complicated, because they are generated in time and space by the three-phase system and are affected by the iron contained in the enclosing structural elements. The magnetomotive force which the no-load current generates in the primary winding produces the stray fiel ...
65-0084 7800 Series Q7800A,B 22
65-0084 7800 Series Q7800A,B 22

... withstand high voltages up to 25,000 Vrms in a salt bath for one minute without breakdown. It is rated at 200°F (93°C) for continuous duty, and up to 350°F (177°C) for intermittent use.) Recommended grounding practices: a. Each 7800 SERIES Relay Module or S7830A will have an earth ground terminal G ...
VIII .Typical Transmission Line Surge Arrester Installation
VIII .Typical Transmission Line Surge Arrester Installation

... causes a tower voltage to raise and results in a back-flashover across an arc horn. This causes transmission line outage and damage of equipment. Because of high frequency range associated with lightning transients phenomena, adequate electrical models are required for which reasons, and simulation ...
PDF Version
PDF Version

... Effective short-circuit protection became possible with the BBC produced a static PPX110/111 (Fig. 6) in the 1970s. introduction of differential protection. First developments This relay was used for supervision and tripping of generators, and the usage for transformer and line protection have been ...
01.4IB.60100B Ground-Gard High Resistance
01.4IB.60100B Ground-Gard High Resistance

... Powered by Safety® ...
Grounding The Powder Coating System
Grounding The Powder Coating System

... may be especially important when a coating of more than 2 mils is required. SAFETY PROBLEMS CAUSED BY POOR GROUNDING All equipment in the powder coating operation and area (as defined by The National Fire Protection Association, NFPA Bulletin Number 33, Chapter 13) must be grounded for safe operatio ...
LM3875 Gainclone - Building Instructions
LM3875 Gainclone - Building Instructions

... R1 is optional and its value can be anything between 200R and 1k (or so). I usually don't install that resistor at all, placing piece of wire in its place. Alternatively, if you need coupling capacitor to protect the amp from DC that may be produced by a source component, a small electrolytic cap ca ...
STATIC FREQUENCY CONVERTERS – A FLEXIBLE AND COST
STATIC FREQUENCY CONVERTERS – A FLEXIBLE AND COST

... Cosmin Banceanu, MSc. Power System Engineer, Control SW Engineer, ABB Switzerland Ltd Thomas Schaad, Senior Engineer, Product Manager for Rail Converters, ABB Switzerland Ltd ...
Power Transformers – Introduction to measurement of losses
Power Transformers – Introduction to measurement of losses

... power of up to 315 kVA suitable for outdoor service and designed to be mounted on the support structures of overhead power lines. Liquid-filled transformers, most often used by electric utilities, have several performance advantages over dry-type transformers. Liquid-filled transformers tend to be m ...
< 1 ... 18 19 20 21 22 23 24 25 26 ... 79 >

Single-wire earth return



Single wire earth return (SWER) or single wire ground return is a single-wire transmission line which supplies single-phase electrical power from an electrical grid to remote areas at low cost. Its distinguishing feature is that the earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire) to act as a return path. Single-wire earth return is principally used for rural electrification, but also finds use for larger isolated loads such as water pumps. It is also used for high-voltage DC over submarine power cables. Electric single-phase railway traction, such as light rail uses a very similar system. It uses resistors to earth to reduce hazards from rail voltages, but the primary return currents are through the rails.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report