• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Alternative Liquids For Tap Changers.
Alternative Liquids For Tap Changers.

... strength, water content) was continuously monitored to ensure realistic testing conditions. Given the distinctive features of silicone oil, its applicability is limited to applications with low mechanical stress and, therefore, only parts of the test program were executed in this regard. HMWHs gener ...
3234-3234W-3478 instruction sheet.ai
3234-3234W-3478 instruction sheet.ai

... ELECTRICAL: If you are performing a new installation, be certain that you make provisions for the proper voltage power supply for your electric strike. If you are performing a retrofit type installation, determine that the voltage present at the location of the strike is appropriate for the TRINE s ...
DC-DC Power Converters
DC-DC Power Converters

... (1 – D) approaches zero. Consequently, the efficiency is high at low duty cycles, but decreases rapidly to zero near D = 1. This behavior is typical of converters having boost or buck-boost characteristics. ...
Radio Frequency Power Amplifier
Radio Frequency Power Amplifier

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

Lesson 22
Lesson 22

... induced in the core causing power loss and (ii) hysteresis effect of the material also causes additional power loss called hysteresis loss. The effect of both the losses will make the core hotter. We must see that these two losses, (together called core loss) are kept to a minimum in order to increa ...
Power System 1 EEE 3231 Transmission Line
Power System 1 EEE 3231 Transmission Line

Placid HD Guide - Twisted Pear Audio
Placid HD Guide - Twisted Pear Audio

... The Placid series of power supplies are shunt regulators. This means the power supply delivers more power, refered to as constant current source (CCS) than is required at any time. The excess power supplied is shunted (shunt current) and transformed into heat. ...
NCL30051LEDGEVB 35-50 Volt, Up to 1.5 Amp, Offline Power Factor
NCL30051LEDGEVB 35-50 Volt, Up to 1.5 Amp, Offline Power Factor

... The boost power factor corrector circuit is composed of MOSFET Q1, boost diode D6, boost inductor L2, and the components associated with the PFC control section and pins of the NCL30051 control IC U1. D5 provides a bypass diode to prevent resonant (L/C) charging of series boost output capacitors C4 ...
A. Internal Inductance
A. Internal Inductance

... in the conductor will set up flux lines. However, the flux beyond a distance D + r2 from the center of the conductor links a net current of zero and therefore does not contribute to the flux linkage of the circuit. Also at a distance less than D  r2 from the center of conductor 1 the current flowin ...
“My 38, 1957 J. T. HARDIN ETAL 3,3333%
“My 38, 1957 J. T. HARDIN ETAL 3,3333%

DMACC - Ind Maint - ELEM 575
DMACC - Ind Maint - ELEM 575

... 20.1 Explain the construction of an AC alternator (generator). 20.2 Discuss the four basic parts of an AC alternator (generator). 20.3 Discuss the operation of an AC alternator (generator). 20.4 Explain instantaneous, peak and effective voltage. 20.5 Discuss phase relationship. 20.6 Discuss inductiv ...
Insulation fault locator EDS460-DG
Insulation fault locator EDS460-DG

... (date, time, channel, event code, measured value), so that all data about an outgoing circuit or an area can be traced back at any time (what happend when). ...
D.C. GENERATOR
D.C. GENERATOR

... Energy is spent when current changes its polarity every half cycle. Power loss due to Hysteresis is given by the equation: ...
Zilano Design for "Reverse Tesla Coil" Free Energy Generator  by Vrand
Zilano Design for "Reverse Tesla Coil" Free Energy Generator by Vrand

module 1
module 1

... conductor will set up flux lines. However, the flux beyond a distance D + r2 from the center of the conductor links a net current of zero and therefore does not contributed to the flux linkage of the circuit. Also at a distance less than D -r2 from the center of conductor 1 the current flowing throu ...
Analog indicators
Analog indicators

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

excitation of dc generator
excitation of dc generator

... charged belts, plates, and disks that carried charge to a high potential electrode. The charge was generated using either of two mechanisms: Electrostatic induction and the triboelectric effect. Because of their inefficiency and the difficulty of insulating machines that produced very high voltages, ...
CS5124DEMO/D Demonstration Note for CS5124 48 V to 5.0 V,
CS5124DEMO/D Demonstration Note for CS5124 48 V to 5.0 V,

... Figure 5 shows the output filter ripple currents at low line and full load. The lower left section shows current supplied to the output by the output filter while the main switch (Q2) is on. The lower right section shows current supplied to the output by the transformer secondary when Q2 is off (dur ...
buchholz relays - Transformer Accessories
buchholz relays - Transformer Accessories

AC generator theory This worksheet and all related files are licensed
AC generator theory This worksheet and all related files are licensed

... 8 poles, which is the same as 4 pole pairs. Follow-up question: algebraically manipulate the speed/poles/frequency equation to solve for the frequency generated (f ) given the number of poles (N ) and the generator speed (S). Answer 11 The rotor cannot be a permanent magnet, but must be an electroma ...
Safety Considerations in Power Supply Design
Safety Considerations in Power Supply Design

Importance of Isolated System
Importance of Isolated System

... NOTE: On the proper system there will be negligible leakage current in parallel in net capacitance due to resistance which is not considered in this example. Considering balanced capacitive load, C1 = C2. We can measure the voltage drop across across system capacitance by using high impedance voltm ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

< 1 ... 60 61 62 63 64 65 66 67 68 ... 183 >

Transformer



A transformer is an electrical device that transfers electrical energy between two or more circuits through electromagnetic induction. Commonly, transformers are used to increase or decrease the voltages of alternating current in electric power applications.A varying current in the transformer's primary winding creates a varying magnetic flux in the transformer core and a varying magnetic field impinging on the transformer's secondary winding. This varying magnetic field at the secondary winding induces a varying electromotive force (EMF) or voltage in the secondary winding. Making use of Faraday's Law in conjunction with high magnetic permeability core properties, transformers can thus be designed to efficiently change AC voltages from one voltage level to another within power networks.Since the invention of the first constant potential transformer in 1885, transformers have become essential for the transmission, distribution, and utilization of alternating current electrical energy. A wide range of transformer designs are encountered in electronic and electric power applications. Transformers range in size from RF transformers less than a cubic centimeter in volume to units interconnecting the power grid weighing hundreds of tons.