• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
TRAX Transformer and Substation Test System
TRAX Transformer and Substation Test System

Energy efficiency and harmonics in electric power systems
Energy efficiency and harmonics in electric power systems

Problem 4 - Portal UniMAP
Problem 4 - Portal UniMAP

... 2. Why do IMs run at low power factor when lightly loaded? Ans At no load an IM draws large magnetizing current (30-40% of full load current) to create flux in the air gap. This current has very low pf of the order 0.2 lag. The power is mainly drawn to provide for core loss. At the motor is loaded, ...
Self -Excited DC Motor
Self -Excited DC Motor

... What is the principle of a dc generator? Answer: A generator is a device which converts mechanical energy into electrical energy. There are two types of generators. They are a) AC Generator and b) DC Generator. An ac generator produces alternating voltage and a dc generator produces direct voltage. ...
Impedance Part 1 File
Impedance Part 1 File

... winding, and Np is the number of turns on the transformer’s primary winding. N is often written as the turns ratio Ns:Ns. The relationship to the impedances can be calculated as: Zs/Zp = (Ns/Np)2 or: Ns/Np = √(Zs/Zp) Zp represents the primary impedance, which is the output impedance of the driving s ...
Harmonic Distortion in Data Centers - Trans-Coil
Harmonic Distortion in Data Centers - Trans-Coil

IGEE 402  – Power System Analysis FINAL EXAMINATION - SAMPLE
IGEE 402 – Power System Analysis FINAL EXAMINATION - SAMPLE

... (d) Draw the approximate voltage profile of this line for the following power delivered: (i) 0 MW, 20 MW, 50 MW, and surge impedance loading. Indicate the methods available to maintain the voltages within the range of 0.95 and 1.05. QUESTION 5 (20 points) A two-bus transmission system consists of th ...
A Practical Guide to `Free Energy` Devices
A Practical Guide to `Free Energy` Devices

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

Electric Field Simulations and Analysis for High Voltage High Power
Electric Field Simulations and Analysis for High Voltage High Power

... Received: 26 December 2016; Accepted: 10 March 2017; Published: 16 March 2017 ...
Diode Applications file
Diode Applications file

... The full-wave bridge rectifier contains four diodes D1, D2, D3 and D4. During the positive half cycle of the secondary voltage the P end of the secondary winding becomes positive while the Q end is negative. D1 and D3 are forward biased while D2 and D4 are reverse biased. Since D1 and D3 are conduc ...
DIVISION 16 - ELECTRICAL
DIVISION 16 - ELECTRICAL

... power. Will supply power for a limited time, to allow an orderly shutdown of equipment without causing damage, or loss of data. M. Withstand Rating – Maximum fault current, at maximum rated voltage, in RMS symmetrical amperes that a device can withstand (pass) during a fault and function after fault ...
Smart Solution for Railway Signalling Infrastructure
Smart Solution for Railway Signalling Infrastructure

Electricity Training Course
Electricity Training Course

...  Explain the proper use of PPE when working on or near electrical equipment.  Explain how to choose the appropriate electrical meter.  Describe proper lockout/tagout methods. Chapter 2 - Fundamentals of Electricity Objectives:  Define resistance and explain how resistors work.  Define capacitan ...
AN-9742 Device Selection Guide for Half-Bridge Welding Machine (IGBT & Diode) Summary
AN-9742 Device Selection Guide for Half-Bridge Welding Machine (IGBT & Diode) Summary

Design and construction of a polygon
Design and construction of a polygon

CURRENT TRANSFORMERS (CT) OPERATED METER CHANGES
CURRENT TRANSFORMERS (CT) OPERATED METER CHANGES

UFC 3-550-03FA Electrical Power Supply and Distribution
UFC 3-550-03FA Electrical Power Supply and Distribution

... planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD(AT&L) Memorandum dated 29 May 2002. UFC will be used for all DoD projects and work for other custom ...
Part 1: Choosing Flux Linkage As An Independent Variable
Part 1: Choosing Flux Linkage As An Independent Variable

... Ferromagnetic circuit analysis provides an engineering tool for the design and control of electric motors and solenoids. In an approximate but useful form of the analysis, magnetic hysteresis is ignored, and eddy currents are approximated by a “shorted-turn” circuit model. The analysis of this paper ...
Understanding The TV Horizontal Output Stage
Understanding The TV Horizontal Output Stage

- Muhazam
- Muhazam

... • It requires a starting power at rotor to produce magnetic field for the induction process to start • After that, the power generated by the generator itself will be used to produce the needed rotor magnetic field CO1 ...
Generator Downsizing Request Form
Generator Downsizing Request Form

Magnetics Booklet v.3
Magnetics Booklet v.3

... primary winding creates an alternating magnetic field in either an air, iron (or soft iron), or laminated steel core. The change of current, as we learned in inductors, creates a opposition voltage. In the secondary winding, the magnetic field in the core creates current and the corresponding voltag ...
Requirement Specification for Optimization of WBAEC
Requirement Specification for Optimization of WBAEC

MiniSub 44KV Manual - English
MiniSub 44KV Manual - English

... damage the cabinet compartments and the cooling radiators. These items can be easily damaged by improper handling. Lifting hooks are provided on all MiniSub tanks and heavy parts such as covers, radiators, radiator banks and core and coil assemblies. Approximate total weight is listed on the outline ...
< 1 ... 46 47 48 49 50 51 52 53 54 ... 183 >

Transformer



A transformer is an electrical device that transfers electrical energy between two or more circuits through electromagnetic induction. Commonly, transformers are used to increase or decrease the voltages of alternating current in electric power applications.A varying current in the transformer's primary winding creates a varying magnetic flux in the transformer core and a varying magnetic field impinging on the transformer's secondary winding. This varying magnetic field at the secondary winding induces a varying electromotive force (EMF) or voltage in the secondary winding. Making use of Faraday's Law in conjunction with high magnetic permeability core properties, transformers can thus be designed to efficiently change AC voltages from one voltage level to another within power networks.Since the invention of the first constant potential transformer in 1885, transformers have become essential for the transmission, distribution, and utilization of alternating current electrical energy. A wide range of transformer designs are encountered in electronic and electric power applications. Transformers range in size from RF transformers less than a cubic centimeter in volume to units interconnecting the power grid weighing hundreds of tons.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report