• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
- sir cr reddy college of engineering
- sir cr reddy college of engineering

... both at unity power factor. What is ratio of copper loss at full load to iron loss? 7. Explain why the open circuit and short circuit test should be conducted on lv and hv sides respectively. 8. two transformers a and B of different ratings but equal voltage ratios share a load of 500kva at 0.8 p.f ...
- sir cr reddy college of engineering
- sir cr reddy college of engineering

... both at unity power factor. What is ratio of copper loss at full load to iron loss? 7. Explain why the open circuit and short circuit test should be conducted on lv and hv sides respectively. 8. two transformers a and B of different ratings but equal voltage ratios share a load of 500kva at 0.8 p.f ...
PowerPoint-præsentation - Dansk Magnetisk Forening
PowerPoint-præsentation - Dansk Magnetisk Forening

... Ørsteds discovery was a deflection of a Compass needle when it is close to a current carrying conductor. But he was not able to describe the physics or mathematics behind the phenomena ...
ppt - MakeItOrTakeIt
ppt - MakeItOrTakeIt

... Soft starter • A soft starter is another form of reduced voltage starter for A.C. induction motors. • The soft starter is similar to a primary resistance or primary reactance starter in that it is in series with the supply to the motor. • The current into the starter equals the current out. • The s ...
Chap 20
Chap 20

... D. 41 mH E. 0.41 H 35. If the magnetic energy stored by a 0.50 H inductor is 3.6 J, what is the current through it? A. 0.13 A B. 0.90 A C. 1.8 A D. 3.8 A E. 5.4 A 38. The current in a 0.40 H inductor increases form 2.0 A to 3.0 A in 1.5 s. The energy stored by the inductor during this process increa ...
Brought to you by Jestine Yong
Brought to you by Jestine Yong

DC POWER SUPPLY BLOCK DIAGRAM OF POWER SUPPLY
DC POWER SUPPLY BLOCK DIAGRAM OF POWER SUPPLY

... In a rectifier, a center-tapped transformer and two diodes can form a full-wave rectifier that allows both half-cycles of the AC waveform to contribute to the direct current, making it smoother than a half-wave rectifier. This form of circuit saves on rectifier diodes compared to a diode bridge, but ...
Special Features in Space Magnetics to support Insulation
Special Features in Space Magnetics to support Insulation

... between primary and various secondary windings. The inner section is hollow and allows the assembly of a ferrite as inner core. The product shown is suitable for a rated voltage of 13.000V, whereby ASP-Epoxy is feasible to insulate up to 30.000V. In a following step the outer core with the wire-wind ...
ayout 1 - Online Power
ayout 1 - Online Power

... on the secondary winding of a power transformer generated from the primary winding and coupled to the secondary. The IsoCare provides significant transverse-mode noise attenuation by reducing the high frequency noise between the input and the output windings of the transformer. ...
Power Plant Electrical Distribution Systems
Power Plant Electrical Distribution Systems

... directly to the Main Generator and as such will provide the cheapest power for the station use since any power from the transmission lines has losses associated with it due to the line losses and transformer losses from whatever step-up transformer provided that power. This Unit Auxiliary Transforme ...
Cast Coil Transformers
Cast Coil Transformers

... Over the last half century, WEG has positioned itself as an industry leading supplier of electric motors, automation products, power transformers, and substation equipment. Now, WEG is doing it again by releasing their latest product in the transformers line: WEG cast coil transformers. Why choose W ...
Magnetic field? - the SASPhysics.com
Magnetic field? - the SASPhysics.com

... • A transformer can change the voltage. • The size of the voltage induced in the secondary coil depends on the number of turns in the primary and secondary coils and also the voltage applied to the ...
Synchronous Generator is a doubly excited machine
Synchronous Generator is a doubly excited machine

... wound rotor or a short-circuited squirrel cage rotor. Three-phase cage rotor induction motors are widely used in industrial drives because they are rugged, reliable and economical. Single-phase induction motors are also used extensively for smaller loads. Although most AC motors have long been used ...
Wind Power Transformer Design - IEEE Power and Energy Society
Wind Power Transformer Design - IEEE Power and Energy Society

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

WLA- Load balancing unit - PT Sinar Elektrindo Perkasa
WLA- Load balancing unit - PT Sinar Elektrindo Perkasa

COMBOLIGHT New Construction Recessed w/ Trim - 12V MR16 - 1 Light
COMBOLIGHT New Construction Recessed w/ Trim - 12V MR16 - 1 Light

The Analysis of Mal-operation of Protection Relay for Detecting
The Analysis of Mal-operation of Protection Relay for Detecting

... As the electric system is getting larger to meet the increasing demand for electric power, the rating of power apparatus is becoming inevitably higher in its working voltage and larger in its capacity. According to KEPCO reports, power transformers in the KEPCO system have undergone troubles such as ...
Chapter 2-b
Chapter 2-b

... portion of the bobbin. In order to overcome the problem of eddy current losses in the core, nickel-iron alloy is used as core material and is slotted longitudinally. Primary winding is connected to an ac source of voltage varying from 5 to 25 V and of frequency ranging from 50 Hz to 20 kHz. When the ...
Berg Heinz-Peter, Fritze Nicole Reliability and vulnerability of
Berg Heinz-Peter, Fritze Nicole Reliability and vulnerability of

... the replacement of 44 transformers which were all commissioned in the year 1965 and, therefore, reach estimated design lifetime of 50 years in 2015 at the latest. Four different options have been analysed:  Option 1 is to use age alone, i.e. to replace all transformers in 2020.  Option 2 incorpora ...
Application Note: AN-114 ITC117P Integrated Telecom Circuit
Application Note: AN-114 ITC117P Integrated Telecom Circuit

... The ITC series integrates the major components found in a typical Data Access Arrangement (DAA), in a 16 lead SOIC package. As highlighted in figure 1, the 1-Form-A MOSFET SSR, Darlington transistor, bridge rectifier, and optical isolator comprise this integral design. Following is the functional ex ...
2.1 Fundamental DC-DC Converter Topologies These graphics
2.1 Fundamental DC-DC Converter Topologies These graphics

COMBOLIGHT New Construction Recessed w/ Trim - 12V AR70 - 2 Light
COMBOLIGHT New Construction Recessed w/ Trim - 12V AR70 - 2 Light

COMBOLIGHT New Construction Recessed w/ Trim - 12V AR70 - 5 Light
COMBOLIGHT New Construction Recessed w/ Trim - 12V AR70 - 5 Light

... adjustable double gimbals. Lamp holder is individually removable and may be regressed 1" (25mm) for additional cutoff. 45° x 45° locking lamp adjustment. Lamp ring features beveled edge and lockable accessory ring that can accept one optical accessory. Additional media holder* can be ordered to allo ...
COMBOLIGHT New Construction Recessed w/ Trim - 12V AR70 - 3 Light
COMBOLIGHT New Construction Recessed w/ Trim - 12V AR70 - 3 Light

... conductors or 60º C for end of run. The fixture is also UL listed as ‘access above ceiling not required’. ...
< 1 ... 127 128 129 130 131 132 133 134 135 ... 183 >

Transformer



A transformer is an electrical device that transfers electrical energy between two or more circuits through electromagnetic induction. Commonly, transformers are used to increase or decrease the voltages of alternating current in electric power applications.A varying current in the transformer's primary winding creates a varying magnetic flux in the transformer core and a varying magnetic field impinging on the transformer's secondary winding. This varying magnetic field at the secondary winding induces a varying electromotive force (EMF) or voltage in the secondary winding. Making use of Faraday's Law in conjunction with high magnetic permeability core properties, transformers can thus be designed to efficiently change AC voltages from one voltage level to another within power networks.Since the invention of the first constant potential transformer in 1885, transformers have become essential for the transmission, distribution, and utilization of alternating current electrical energy. A wide range of transformer designs are encountered in electronic and electric power applications. Transformers range in size from RF transformers less than a cubic centimeter in volume to units interconnecting the power grid weighing hundreds of tons.