• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Three Port Flyback MicroInverter to Interface Renewable Energy
Three Port Flyback MicroInverter to Interface Renewable Energy

... Fig. 1 shows a typical microinverter-based PV system, where the microinverter is integrated to the PV panel, and feeds the collected solar power directly into the utility grid. Usually, for safety purposes and leakage current in gridconnected applications, a high-frequency transformer is embedded in ...
Motor start-up
Motor start-up

... Autotransformer start-up This method is often used for starting up large motor loads. The autotransformer has a main winding designed for the rated voltage with a terminal which is connected to the motor. Noratel supplies both single and threephase transformers. The combination of large electric mot ...
MP65 HIGH VOLTAGE DC FROM AC BY USING COCKCROFT
MP65 HIGH VOLTAGE DC FROM AC BY USING COCKCROFT

How a Dimmer Works
How a Dimmer Works

10W, Dual Output Power Supply
10W, Dual Output Power Supply

... below. Schottky rectifiers are used for output diodes for maximum efficiency. The NCP1014 controller contains inherent over-current and overtemperature protection in addition to over-voltage protection in the event of an optocoupler failure. January 2007, Rev. 1 ...
Typical Causes of Winding Failuresin Three-Phase
Typical Causes of Winding Failuresin Three-Phase

... Thermal deterioration of insulation in one phase of the stator winding can result from unequal voltage between phases. Unequal voltages usually are caused by unbalanced loads on the power source, a poor connection at the motor terminal, or a high resistance contact (weak spring). Note: A one-percent ...
Programmable Electronic Voltage Burden
Programmable Electronic Voltage Burden

PS1: Overcurrent Protection of a Substation Power Transformer
PS1: Overcurrent Protection of a Substation Power Transformer

... protect power transformers is their long operating time under low overcurrent conditions. This delays transformer disconnection, and in certain cases, provides little protection to the transformer. The protection schemes for large power transformers usually include differential protection and/or res ...
Wireless Music transmission and reception by IR
Wireless Music transmission and reception by IR

EE_ece_3rd - Jasdev Singh Sandhu Group of Institutes
EE_ece_3rd - Jasdev Singh Sandhu Group of Institutes

Induction motor control
Induction motor control

... Electrical power converted into mechanical power (developed power in the rotor). Pm = Total air gap power transferred across the air gap for a three phase induction motor (Pag) – copper loss in the rotor (Pcur) ...
Electrical_Engineeri.. - Engineers Institute of India
Electrical_Engineeri.. - Engineers Institute of India

Rakib & Mukul
Rakib & Mukul

... inductance and stray capacitance to improve high-frequency response. This can be done by splitting up each coil into sections, and those sections placed in layers between the sections of the other winding. This is known as a stacked type or interleaved winding. Both the primary and secondary winding ...
Document
Document

static voltage regulator.cdr
static voltage regulator.cdr

Transformer Testing Experience by LVI/FRA Methods. Short
Transformer Testing Experience by LVI/FRA Methods. Short

isolation transformer
isolation transformer

... coupling a result of the changing magnetic flux lines of one coil cutting through the second coil. Turns ratio The ratio of the turns in the secondary winding to the turns in the primary winding. Reflected The resistance of the secondary circuit resistance reflected into the primary circuit. Impedan ...
3.002 How are Neon Transformers different from the more
3.002 How are Neon Transformers different from the more

Soft Magnetic Materials for Audio Transformers
Soft Magnetic Materials for Audio Transformers

... the sand studied. The frequencies at which these occurred were confirmed by bridge measurement of the variations of impedance and radiation resistance at each resonance [1]. It is worth recording that even the resonances of the actual moving coils were found to be audible by bowing, and the frequenc ...
A Simplified Analysis of the Broadband Transmission Line Transformer
A Simplified Analysis of the Broadband Transmission Line Transformer

On-site Measurement of Load and No-load Losses of
On-site Measurement of Load and No-load Losses of

... In the further conversion of the measured power load loss in transformers and bringing it in line with nominal power and reference temperature, the uncertainty of measurement is increased by the errors made in measuring the resistance of windings and the temperature. The error made in measuring the ...
Pax Presentation
Pax Presentation

... • 2 kV output (peak) • DC – 1 kHz @ 50 mA max current • Capacitance range o 4 µF @ 1 Hz o 80 nF @ 50 Hz (67 nF @ 60 Hz) o 4 nF @ 1 kHz ...
a new railway power flow control system coupled with
a new railway power flow control system coupled with

... To overcome the disadvantages, various IGBT- or IGCTbased active compensating systems were put forward in the last 20 years. Among them, RPC gets more attention due to its universalness. It can deal with almost all power quality problems of two-phase and single-phase traction supply system. However, ...
Mutual inductance
Mutual inductance

... Two coils are said to have a mutual inductance of 1 H if an e.m.f. of 1 V is induced in the secondary when the current in the primary changes at the rate of 1 A s-1. Induction coils such as this are used in car ignition circuits, and used to be a source of high voltage for research. The long solenoi ...
EE-0903478-Electrical Machines Laboratory-April-2015
EE-0903478-Electrical Machines Laboratory-April-2015

... Use the testing data to calculate the equivalent circuit parameters of the tested machines. ...
< 1 ... 119 120 121 122 123 124 125 126 127 ... 183 >

Transformer



A transformer is an electrical device that transfers electrical energy between two or more circuits through electromagnetic induction. Commonly, transformers are used to increase or decrease the voltages of alternating current in electric power applications.A varying current in the transformer's primary winding creates a varying magnetic flux in the transformer core and a varying magnetic field impinging on the transformer's secondary winding. This varying magnetic field at the secondary winding induces a varying electromotive force (EMF) or voltage in the secondary winding. Making use of Faraday's Law in conjunction with high magnetic permeability core properties, transformers can thus be designed to efficiently change AC voltages from one voltage level to another within power networks.Since the invention of the first constant potential transformer in 1885, transformers have become essential for the transmission, distribution, and utilization of alternating current electrical energy. A wide range of transformer designs are encountered in electronic and electric power applications. Transformers range in size from RF transformers less than a cubic centimeter in volume to units interconnecting the power grid weighing hundreds of tons.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report