
MAX17595/MAX17596/MAX17597 Peak-Current-Mode Controllers for Flyback and Boost Regulators General Description
... Note 3: The MAX17595 is intended for use in universal input power supplies. The internal clamp circuit at VIN is used to prevent the bootstrap capacitor from charging to a voltage beyond the absolute maximum rating of the device when EN is low (shutdown mode). Externally limit the maximum current t ...
... Note 3: The MAX17595 is intended for use in universal input power supplies. The internal clamp circuit at VIN is used to prevent the bootstrap capacitor from charging to a voltage beyond the absolute maximum rating of the device when EN is low (shutdown mode). Externally limit the maximum current t ...
MAX6576/MAX6577 SOT Temperature Sensors with Period/Frequency Output General Description
... microcontrollers (µCs) or microprocessors (µPs). The MAX6576 converts ambient temperature into a 50% dutycycle square wave with a period proportional to absolute temperature. The MAX6577 converts ambient temperature into a 50% duty-cycle square wave with a frequency proportional to absolute temperat ...
... microcontrollers (µCs) or microprocessors (µPs). The MAX6576 converts ambient temperature into a 50% dutycycle square wave with a period proportional to absolute temperature. The MAX6577 converts ambient temperature into a 50% duty-cycle square wave with a frequency proportional to absolute temperat ...
AD8033/AD8034 Low Cost, 80 MHz FastFET Op Amps Data Sheet
... Analog Devices, Inc., proprietary XFCB process offer significant performance improvements over other low cost FET amps, such as low noise (11 nV/√Hz and 0.7 fA/√Hz) and high speed (80 MHz bandwidth and 80 V/μs slew rate). With a wide supply voltage range from 5 V to 24 V and fully operational on a s ...
... Analog Devices, Inc., proprietary XFCB process offer significant performance improvements over other low cost FET amps, such as low noise (11 nV/√Hz and 0.7 fA/√Hz) and high speed (80 MHz bandwidth and 80 V/μs slew rate). With a wide supply voltage range from 5 V to 24 V and fully operational on a s ...
Electrical Installation Guide 2016 | Schneider Electric
... b Without limitation during light-load periods in winter, and in spring and summer. During the periods of limitation, reactive energy consumption exceeding 40% of the active energy (i.e. tan ϕ > 0.4) is billed monthly at the current rates. Thus, the quantity of reactive energy billed in these period ...
... b Without limitation during light-load periods in winter, and in spring and summer. During the periods of limitation, reactive energy consumption exceeding 40% of the active energy (i.e. tan ϕ > 0.4) is billed monthly at the current rates. Thus, the quantity of reactive energy billed in these period ...
section 15172
... W. The VFD shall include Industry specific application macros. The macros can be used to help facilitate start-up. The macros will provide initialization to program all parameters and customer interfaces for a particular application, to reduce programming time. ...
... W. The VFD shall include Industry specific application macros. The macros can be used to help facilitate start-up. The macros will provide initialization to program all parameters and customer interfaces for a particular application, to reduce programming time. ...
Low Voltage Current Mode Push-Pull PWM
... The UCC3808A is a family of BiCMOS push-pull, high-speed, low-power, pulse-width modulators. The UCC3808A contains all of the control and drive circuitry required for off-line or dc-to-dc fixed frequency current-mode switching power supplies with minimal external parts count. The UCC3808A dual outpu ...
... The UCC3808A is a family of BiCMOS push-pull, high-speed, low-power, pulse-width modulators. The UCC3808A contains all of the control and drive circuitry required for off-line or dc-to-dc fixed frequency current-mode switching power supplies with minimal external parts count. The UCC3808A dual outpu ...
modelling of loads in power flow analysis
... The power flow analysis provides the nodal voltages and phase angles and hence the power injected at all the buses and power flows through interconnecting power channels. The optimal power flow is used to optimize the load flow solutions of large scale power system. This is done by minimizing the se ...
... The power flow analysis provides the nodal voltages and phase angles and hence the power injected at all the buses and power flows through interconnecting power channels. The optimal power flow is used to optimize the load flow solutions of large scale power system. This is done by minimizing the se ...
part 1 general - Rockwell Automation
... manufacturer of medium voltage variable frequency drives for use in similar applications at the specified voltage and power ratings. A user list, complete with contact names and telephone numbers, shall be furnished upon request. ...
... manufacturer of medium voltage variable frequency drives for use in similar applications at the specified voltage and power ratings. A user list, complete with contact names and telephone numbers, shall be furnished upon request. ...
SEMITOP 3 Power Board
... Application Note was written for TRIAC, the isolation constraints still apply for fast switching semiconductor devices such as IGBTs.) ...
... Application Note was written for TRIAC, the isolation constraints still apply for fast switching semiconductor devices such as IGBTs.) ...
Integrated Inductors for RF Transmitters in CMOS/MEMS Smart Microsensor Systems
... 300-MHz. The low Q-factor is due to parasitic effects such as magnetic field penetration, metal– substrate capacitance, and so on. The measured resonant frequency was about 600-MHz. When an inductor is integrated on silicon, some undesirable induced effects show up. The reason is that the metallic l ...
... 300-MHz. The low Q-factor is due to parasitic effects such as magnetic field penetration, metal– substrate capacitance, and so on. The measured resonant frequency was about 600-MHz. When an inductor is integrated on silicon, some undesirable induced effects show up. The reason is that the metallic l ...
LAPPEENRANTA UNIVERSITY OF TECHNOLOGY DEPARTMENT
... Microturbines are power plants where the generator is a rotating field machine, often a permanent magnet machine which operates at a high inconstant speed. It is a very important new generation technology. Microturbines consume different types of fuel including natural-gas, gasoline and other liquid ...
... Microturbines are power plants where the generator is a rotating field machine, often a permanent magnet machine which operates at a high inconstant speed. It is a very important new generation technology. Microturbines consume different types of fuel including natural-gas, gasoline and other liquid ...
AC-DC sensitive residual current devices (Type B RCDs)
... contain a PFC stage or a boost converter in the intermediate circuit in order to raise the intermediate circuit voltage so that electric motors designed for a rated voltage of 400 V can also be connected. If frequency converters of this type are used, however, residual currents may occur in the even ...
... contain a PFC stage or a boost converter in the intermediate circuit in order to raise the intermediate circuit voltage so that electric motors designed for a rated voltage of 400 V can also be connected. If frequency converters of this type are used, however, residual currents may occur in the even ...
he inverter is one of the most important and most complex
... How much load can an inverter handle? Its power output is rated in watts (watts = amps x volts). There are three levels of power rating—a continuous rating, a limited-time rating, and a surge rating. Continuous means the amount of power the inverter can handle for an indefinite period of hours. When ...
... How much load can an inverter handle? Its power output is rated in watts (watts = amps x volts). There are three levels of power rating—a continuous rating, a limited-time rating, and a surge rating. Continuous means the amount of power the inverter can handle for an indefinite period of hours. When ...
Utility frequency
The utility frequency, (power) line frequency (American English) or mains frequency (British English) is the frequency of the oscillations of alternating current (AC) in an electric power grid transmitted from a power plant to the end-user. In large parts of the world this is 50 Hz, although in the Americas and parts of Asia it is typically 60 Hz. Current usage by country or region is given in the list of mains power around the world.During the development of commercial electric power systems in the late 19th and early 20th centuries, many different frequencies (and voltages) had been used. Large investment in equipment at one frequency made standardization a slow process. However, as of the turn of the 21st century, places that now use the 50 Hz frequency tend to use 220–240 V, and those that now use 60 Hz tend to use 100–127 V. Both frequencies coexist today (Japan uses both) with no great technical reason to prefer one over the other and no apparent desire for complete worldwide standardization.Unless specified by the manufacturer to operate on both 50 and 60 Hz, appliances may not operate efficiently or even safely if used on anything other than the intended frequency.